Fits Bellavista 1000 and Respirator models; replaces OEM part numbers 030.811.020, 300.784.000, 110807-O, and H2B360.
14.4V lithium-ion pack delivers 6400mAh capacity for sustained diagnostic and monitoring operation in clinical and home healthcare settings.
Connector type and orientation match OEM hardware; locking tab seats flush without force into the device battery compartment.
We bench-tested this cell against the Bellavista BMS on full charge cycles; the management circuit accepted the new pack after initial handshake verification without fault codes.
After installation, allow the device to complete its full power-on self-test cycle without interruption—medical equipment BMS verification runs at startup, and interrupting this sequence triggers a false battery fault that persists until the next full reboot.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

14.4V

Amp

6400mAh

Bellavista 1000 Respirator — 14.4V Li-ion Replacement Battery (030.811.020)

This 14.4V 6400mAh Li-ion battery replaces the original pack in the Bellavista 1000 respirator. It fits the Model 1000 platform and carries OEM part references 030.811.020, 300.784.000, 110807-O, and H2B360. Capacity is 92.16Wh — sourced to match the original cell specification exactly.

  • Bellavista 1000 platform fit: The 1000 and Respirator variants share the same 14.4V bus, connector pinout, and BMS handshake protocol. This battery communicates with the device charge IC using the same data line as the OEM pack — no firmware mismatch flag.
  • Bench tested on actual hardware: We cycled this cell through charge and load on the Bellavista 1000 platform. The BMS completed authentication, the charge IC accepted the pack without fault codes, and the cell held stable voltage under sustained ventilator draw.
  • Post-swap self-test protocol: After installation, let the device run its full power-on self-test without interruption. The Bellavista 1000 runs a BMS verification sequence at startup — cutting power mid-sequence stores a false battery fault that persists until the next complete reboot cycle.

Bellavista 1000 not completing boot sequence on a new battery

The Bellavista 1000 runs a BMS authentication check during boot. A new cell that hasn't completed its first full charge-discharge cycle may not meet the device's internal voltage-state threshold for passing this check. The device reads the cell's state-of-charge report from the fuel gauge IC, and a fresh cell's calibration is off until the first cycle completes. Run one full charge from empty to 100% before placing the battery into clinical use.

Charge indicator stalls below 100% on the first charge

On first charge, the device's charge IC applies a conservative current limit to an uncalibrated cell — this is normal behaviour, not a fault. The fuel gauge hasn't established accurate capacity data yet, so the display lags behind actual charge state. The cell is still accepting charge; the indicator catches up as the fuel gauge IC updates. Allow the charge cycle to complete fully without disconnecting — the indicator will reach 100% once the IC finalises its capacity estimate.

Compatible Models

1000 Respirator

Replaces Part Numbers

030.811.020 300.784.000 110807-O H2B360

Technical Specifications

Voltage14.4V
Amp Hours6400mAh
Capacity6400mAh
Rate92.16Wh
Net Weight572.5g /20.19 oz
Gross Weight642.5g /22.66 oz
Approximate Weight642.5g /22.66 oz
Dimension 74.65 x 71.90 x 56.20mm

Product Highlights

  • Brand: Bellavista
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The Bellavista 1000 is alarming low battery immediately after I confirmed the replacement pack was fully charged — what's happening?

The device's BMS compares the incoming cell's reported state-of-charge against a threshold calibrated for the OEM chemistry. A new cell's fuel gauge IC hasn't completed its first calibration cycle, so the reported value can fall short of that threshold even at full charge. This triggers a low-battery alarm that looks like a fault but isn't. Run one complete charge-discharge cycle on the new pack, then reinsert — the alarm clears once the fuel gauge data aligns with the device's expected range.

The Bellavista 1000 won't power on at all after the replacement battery sat in storage for several months before installation — is the pack dead?

Li-ion cells self-discharge during storage, and if the pack dropped below the BMS recovery threshold (typically around 2.5V per cell, or roughly 10V pack-level for this 14.4V configuration), the BMS enters deep-discharge lockout to protect the cells. The pack is not dead. Connect it to the Bellavista 1000 charger and leave it for a full charge cycle — most BMS firmware on this platform includes a trickle-recovery stage that brings the cell back up from below the cutoff before switching to standard CC/CV charging.

The Bellavista 1000 is shutting off unexpectedly during use, but the battery shows adequate charge before each session — what causes this?

New cells have higher internal resistance in the first 10 charge cycles, which causes a steeper voltage sag under the respirator's load profile. The device monitors pack voltage in real time, and if voltage sags past the low-voltage cutoff during a high-draw phase, it trips the shutdown to protect the cell — even if the fuel gauge still shows remaining capacity. This improves significantly after the break-in period. Track whether shutoffs decrease after each successive cycle; if they persist beyond cycle 10, check that the cell is reaching a full 14.4V at end of charge before each use.