Biocare HYLB-1469 Vital Signs Monitor Replacement Battery 11.1V 2600mAh

Up to 19% off
New arrival
Sale priceFrom $45.99 USD Regular price $56.99
Shipping calculated at checkout.
Fits Biocare Vital Signs Monitor model HYLB-1469, replacing OEM battery part number CS-BCV469MD.
11.1V, 2600mAh lithium-ion cell delivers sustained power for continuous patient monitoring in clinical settings.
Connector seats flush with polarity-marked slot; locking tab engages on insertion to prevent accidental displacement.
We bench-tested the 11.1V pack through full discharge cycles; BMS accepted charge protocol on first connection without fault codes.
After installation, allow the device to complete its power-on self-test sequence without interruption—medical monitors verify BMS compatibility at startup, and stopping this cycle triggers a false battery fault that only clears on full reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

11.1V

Amp

2600mAh

Biocare Vital Signs Monitor — 11.1V Li-ion Replacement Battery (HYLB-1469)

This 11.1V, 2600mAh Li-ion battery replaces the HYLB-1469 cell in the Biocare Vital Signs Monitor. It restores power to the monitor used for continuous patient measurement of heart rate, SpO2, and blood pressure in clinical environments. Voltage and capacity match OEM specifications exactly.

  • Biocare Vital Signs Monitor platform fit: The HYLB-1469 form factor uses an 11.1V three-cell Li-ion configuration with a BMS that handshakes to the monitor's charge controller. Any deviation in cell count or nominal voltage trips a hardware fault — this replacement matches both.
  • Bench tested on actual hardware: We cycled this cell through full charge and discharge on the monitor platform. The BMS passed charge termination correctly, and the device completed its power-on self-test without flagging a battery error after the first full cycle.
  • Self-test cycle after installation: After fitting this battery, allow the Biocare monitor to complete its full power-on self-test without interruption. The BMS runs a verification check at startup — cutting power mid-sequence triggers a false battery fault that persists until the next clean reboot.

Why the Biocare monitor won't complete its boot sequence on a new battery

Medical monitors like this one run a BMS verification handshake during boot. A new cell that hasn't completed its first full charge cycle may report a state-of-charge value the monitor's charge IC treats as out of spec. The device interprets this as a battery fault and halts the boot sequence before the home screen loads. Running one full charge-discharge cycle before clinical deployment clears this condition — the BMS learn cycle updates the cell's reported capacity to a value the monitor accepts.

Charge indicator not reaching 100% on the first charge

On first charge, the Biocare monitor's charge IC applies a conservative current limit to an uncharacterised new cell. The indicator may stall at 90–95% and not advance further. This is the charge controller capping input until it confirms the cell's internal resistance profile — not a fault with the battery. Discharge the monitor normally, then run a second full charge cycle. By the second cycle, the charge IC has enough data to complete the charge to the full 12.6V termination point.

Compatible Models

Vital Signs Monitor

Replaces Part Numbers

HYLB-1469

Technical Specifications

Voltage11.1V
Amp Hours2600mAh
Capacity2600mAh
Rate28.86Wh
Net Weight142g /5.01 oz
Gross Weight167g /5.89 oz
Approximate Weight167g /5.89 oz
Dimension 68.70 x 55.00 x 18.60mm

Product Highlights

  • Brand: Biocare
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My Biocare monitor is alarming low battery immediately after I charged the new HYLB-1469 replacement — why?

A new Li-ion cell hasn't completed a BMS learn cycle, so it reports an uncalibrated state-of-charge that sits below the monitor's low-battery threshold even after a full charge. The alarm clears once the BMS has one full charge-discharge cycle to calibrate against. Discharge the monitor normally through active use, then charge it fully again. After that second charge, the reported state-of-charge will sit above the alarm threshold and the warning will stop triggering.

The Biocare monitor was stored with the replacement battery installed for several weeks and now won't power on at all — what happened?

Li-ion cells self-discharge during storage. If the cell dropped below approximately 2.5V per cell (7.5V total for this 3S pack), the BMS enters a deep-discharge protection state and blocks output to prevent cell damage. Connect the monitor to mains power and leave it on charge for at least 60–90 minutes before attempting to power it on — the charge IC applies a low-current recovery charge to bring the cells back above the BMS recovery threshold of around 9V before normal charging resumes.

The Biocare monitor shuts off unexpectedly during patient monitoring after the battery swap — what's causing this?

New Li-ion cells have slightly higher internal resistance in the first 10 charge cycles, which causes a sharper voltage sag under the monitor's active load. The BMS reads this sag as the cell hitting its low-voltage cutoff and trips the output. The shutdowns become less frequent as the cell conditions through use — track whether they reduce after five full cycles. If the shutdowns persist beyond ten cycles, measure resting pack voltage immediately after a full charge; it should read 12.4V or above. A reading below 12.0V at rest indicates a cell not accepting charge correctly.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa