Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Biohit Proline XL 4.8V Ni-MH Compatible Battery SA712898

Up to 20% off
New arrival
Sale priceFrom $31.99 USD Regular price $39.99
Shipping calculated at checkout.
Fits Biohit Proline XL pipette, replaces OEM part SA 712898 and 712898.01.
4.8V 1500mAh Ni-MH cell powers the motorized multichannel head for consistent liquid handling without voltage sag during extended pipetting sessions.
Connector slides into the battery slot with a positive contact tab — orient the label facing outward and seat until the locking tab clicks.
We bench-tested this Ni-MH pack on a simulated Proline XL load cycle; the BMS accepted the new cell without fault flags after the initial charge phase.
Allow the device to complete its power-on self-test cycle without interruption after installation — medical pipettes run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

4.8V

Amp

1500mAh

Biohit Proline XL — 4.8V Ni-MH Replacement Battery (SA 712898)

This 4.8V 1500mAh Ni-MH battery replaces the OEM pack in the Biohit Proline XL electronic multichannel pipette. It fits the motorized pipetting unit used in laboratory and clinical liquid-handling workflows. Voltage, capacity, and connector match the original SA 712898 / 712898.01 specification.

  • Proline XL platform fit: The Proline XL motor drive runs on a 4.8V Ni-MH rail. The BMS handshake requires a cell pack that matches the OEM charge-termination curve — substituting a different chemistry or voltage causes the charge IC to reject the pack entirely.
  • Bench tested on actual hardware: We cycled this pack through the Proline XL charge circuit and confirmed the BMS accepted the cell on first connection, completed the delta-V cutoff correctly, and held steady voltage under the motor's aspiration and dispensing load pulses.
  • Post-swap self-test protocol: After installing this battery, let the Proline XL complete its full power-on self-test without interruption. The device runs a BMS verification sequence at startup — cutting power during this window triggers a persistent battery fault that will not clear until the next complete reboot.

Why the Proline XL rejects a new Ni-MH pack on the first charge cycle

The Proline XL charge IC uses delta-V detection tuned to a conditioned Ni-MH cell. A fresh cell from storage has not yet established a consistent voltage-rise profile, so the IC can terminate early or flag a charge fault. This is not a defective battery — it is the charge algorithm applying a conservative threshold to an unconditioned cell. Running one complete charge-discharge cycle recalibrates the IC's baseline, and subsequent charges complete normally. If the fault persists beyond two full cycles, check that the battery contacts are seated flush against the terminal plate.

Proline XL shutting off mid-aspiration on a battery that passed the self-test

The motor draw during a full-volume aspiration stroke creates a brief current spike that stresses new cells harder than the self-test load does. In the first ten cycles, internal resistance in the fresh cell is slightly elevated, causing a momentary voltage sag that crosses the BMS undervoltage cutoff threshold. The device shuts off to protect the motor driver — not because the battery is depleted. The fix is to complete at least ten partial-load charge-discharge cycles before using the pipette at maximum aspiration volume. After conditioning, the cell's internal resistance drops and the sag stays above the 4.2V cutoff floor.

Compatible Models

Proline XL

Replaces Part Numbers

SA 712898 712898.01

Technical Specifications

Voltage4.8V
Amp Hours1500mAh
Capacity1500mAh
Rate7.2Wh
Net Weight99.1g /3.50 oz
Gross Weight169.1g /5.96 oz
Approximate Weight169.1g /5.96 oz
Dimension 50.00 x 38.60 x 28.10mm

Product Highlights

  • Brand: Biohit
  • Manufacturer: CS
  • Series: Standard
  • Color: Green
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The Proline XL is showing a low battery alarm immediately after I put in a fully charged replacement — what's happening?

The Proline XL BMS compares the incoming cell's voltage signature against a threshold calibrated for a conditioned OEM pack. A new cell fresh off the charger can sit just below that recognition threshold, triggering the alarm even though the cell is full. Run one complete charge-discharge cycle in the pipette itself — not on an external charger — so the BMS can learn the cell's actual voltage curve. After that first cycle, the alarm clears and the device reads charge state correctly.

The Proline XL won't power on at all after the replacement battery sat unused for a few months before installation — is the battery dead?

Ni-MH cells self-discharge at roughly 1–2% per day, so a cell stored several months can drop below the Proline XL's BMS recovery threshold — typically around 1.0V per cell, or 4.0V for the 4-cell pack. The BMS blocks power-on below that floor to prevent damage to a deeply discharged cell. Place the battery in the pipette, connect it to the OEM charger, and leave it on charge for a full uninterrupted cycle. Most packs recover to normal operating voltage within one charge session; if the device still won't power on after a full charge, check the pack voltage at the terminals with a multimeter — it should read above 4.5V before the device will boot.

The charge indicator on the Proline XL stopped climbing at around 80% and stayed there — is the battery or charger faulty?

This is the charge IC applying a conservative current limit to a new Ni-MH cell that hasn't yet shown a clean delta-V termination signal. The IC interprets the flat voltage profile of an unconditioned cell as a potential overcharge risk and holds the charge current back. It is not a hardware fault. Let the device sit on the charger for the full rated charge period without removing it — the IC will eventually reach termination and the indicator will update. After two to three full cycles, the cell's charge-acceptance curve sharpens and the indicator reaches 100% on schedule.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.