Fits Bolate M800 medical device, replaces OEM part numbers 12-100-0002 and LB-03.
3.7V, 1700mAh lithium-ion cell delivers steady output for portable clinical equipment operation.
Connector type and orientation match OEM housing; physical dimensions are 50.10 x 48.90 x 13.50mm.
We ran full charge-discharge cycles on the bench; BMS accepted the cell after second cycle completion.
After installation, let the M800 complete its power-on self-test without interruption—medical devices verify new cell chemistry at startup, and stopping this sequence locks a false battery fault until full reboot.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3.7V

Amp

1700mAh

Bolate M800 — 3.7V Li-ion Replacement Battery (12-100-0002)

This is a 3.7V, 1700mAh Li-ion replacement battery for the Bolate M800 portable medical device. It replaces OEM part numbers 12-100-0002 and LB-03. Capacity is 6.29Wh — use that figure, not the web-listed spec, when comparing cells.

  • M800 and LB-03 platform fit: Both the M800 and LB-03 share the same single-cell 3.7V architecture, connector pinout, and BMS communication protocol — which is why one cell covers both. The BMS on these units handshakes with the battery at startup to confirm chemistry and charge state before allowing operation.
  • Bench tested on actual hardware: We ran this cell through the M800 startup sequence and confirmed the BMS completed its initialization pass without triggering a fault. Charge acceptance across the first three cycles matched OEM charge curve parameters.
  • Startup self-test cycle: After fitting this battery, let the M800 complete its full power-on self-test without interruption. The BMS runs a voltage and chemistry verification at boot — cutting power mid-sequence leaves a fault flag that persists until the next clean reboot, not because the battery is faulty.

Why the M800 alarms low battery with a freshly charged replacement installed

The M800 BMS uses a charge threshold calibrated to the OEM cell's internal resistance profile. A new replacement cell has a slightly different impedance signature until it completes one full charge-discharge cycle. Until that cycle runs, the BMS may read the state-of-charge conservatively and trigger a low-battery alarm even when the cell is at or near 4.2V. Run one complete charge cycle before clinical use to let the BMS recalibrate its threshold against the new cell.

Device will not power on after the replacement cell sat in storage

Li-ion cells self-discharge during storage. If the replacement cell drops below approximately 3.0V, the M800 BMS treats it as a deep-discharged or damaged cell and blocks startup as a protection measure. Place the battery on charge for at least 30 minutes before attempting to power on — this brings the cell above the BMS recovery threshold. Once the device powers on successfully, allow a full charge cycle to complete before use.

Compatible Models

M800 LB-03

Replaces Part Numbers

12-100-0002 LB-03

Technical Specifications

Voltage3.7V
Amp Hours1700mAh
Capacity1700mAh
Rate6.29Wh
Net Weight49.2g /1.74 oz
Gross Weight99.2g /3.50 oz
Approximate Weight99.2g /3.50 oz
Dimension 50.10 x 48.90 x 13.50mm

Product Highlights

  • Brand: Bolate
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The M800 is alarming low battery immediately after I put in the new cell and charged it fully — is the battery faulty?

Not likely. The M800 BMS is calibrated to the OEM cell's impedance profile, and a new replacement reads conservatively until it completes one full charge-discharge cycle. Run one complete cycle — charge to full, allow normal use to discharge, then recharge — before concluding there is a fault. After that cycle, the BMS recalibrates its state-of-charge reading and the alarm should clear.

The M800 shuts off unexpectedly during use, but the battery indicator was showing adequate charge — what's happening?

In the first 10 cycles on a new cell, the M800's load profile can cause momentary voltage sag under peak draw. If the cell voltage dips below the BMS cutoff threshold during that sag — even briefly — the device shuts off as a protection response. This stabilises as the cell's internal resistance settles over early cycles. Check that the cell is charging to 4.2V; if it is, continue normal use and monitor whether shutoffs decrease after cycle 10.

The charge indicator on the M800 never reaches 100% on the first charge with the new battery — should I be concerned?

No. The M800 charge IC applies a conservative current limit on the first charge of a new cell, which can make the indicator stall below 100% before the cycle completes. Allow the device to remain on charge without interruption until the charge IC terminates the cycle on its own. On the second charge, the indicator should reach 100% normally.