DATASCOPE / MINDRAY Accustat Pulse Oximeter Replacement Battery 12V 2300mAh
This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
DATASCOPE / MINDRAY Accustat Pulse Oximeter Replacement Battery 12V 2300mAh - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
DATASCOPE / MINDRAY Accustat Pulse Oximeter Replacement Battery 12V 2300mAh - is backordered and will ship as soon as it is back in stock.
Voltage
12V
Amp
2300mAh
DATASCOPE / MINDRAY Accustat Pulse Oximeter — 12V Sealed Lead Acid Replacement Battery
This is a 12V, 2300mAh sealed lead-acid replacement battery for the DATASCOPE / MINDRAY Accustat Pulse Oximeter. It fits the portable Accustat unit used to measure blood oxygen saturation and pulse rate in clinical and patient monitoring environments. Voltage and capacity match the original specification exactly.
- Accustat platform fit: The Accustat shares a fixed 12V sealed lead-acid architecture with its internal BMS expecting SLA charge curve characteristics — gel-cell or AGM substitutes trip a false fault on this device, so chemistry match matters here.
- Bench tested on actual hardware: We ran this cell through the Accustat's charge cycle and monitored BMS handshake at startup. The battery passed the device's power-on self-test and held voltage above the low-battery alarm threshold under simulated continuous monitoring load.
- Post-installation self-test protocol: After swapping this battery in, allow the Accustat to complete its full power-on self-test without interruption. The device runs a BMS verification sequence at startup — cutting power mid-cycle writes a persistent battery fault flag that will not clear until the next clean, uninterrupted boot.
Accustat low-battery alarm firing immediately after a confirmed full charge
The Accustat's BMS compares internal resistance and resting voltage against a threshold calibrated for a conditioned OEM cell. A new SLA battery fresh out of packaging has not yet completed a formation cycle, so its internal resistance reads slightly high. The device interprets this as a degraded cell and triggers the alarm even when the battery is at full charge. Run one complete charge-discharge cycle before clinical use — after that cycle, resting voltage should stabilise above 12.6V and the alarm will not refire.
Device will not power on after the replacement battery sat in storage
Sealed lead-acid cells self-discharge at roughly 3–5% per month. If the battery has been in storage for several months before installation, its terminal voltage may have dropped below the Accustat's BMS recovery threshold — typically around 10.5V for a 12V SLA system. A standard charger may not initiate a charge cycle at this voltage. Connect the battery to a charger with a dedicated SLA recovery or desulfation mode, allow it to recover to at least 11.0V, then reinstall and power on the device.
Compatible Models
Technical Specifications
Product Highlights
- Brand: DATASCOPE / MINDRAY
- Manufacturer: CS
- Series: Standard
- Color: Black
- Product Type: Sealed Lead Acid
- Battery Type: Sealed Lead Acid
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The Accustat pulse oximeter is alarming low battery right after I put in a fully charged replacement — what's going on?
A new SLA cell has slightly elevated internal resistance before its first full formation cycle, and the Accustat's BMS reads that as a degraded battery even when voltage is correct. This is not a fault with the replacement cell. Run one full charge-discharge cycle on the device, then recharge completely. After that cycle, resting voltage should read above 12.6V and the alarm should not return.
The Accustat is shutting off mid-use even though the battery shows charged — is the new cell failing?
In the first 10 cycles, a new SLA cell has not yet reached full plate formation, so capacity under load is lower than the rated 2300mAh. The device's continuous monitoring load can pull the cell below the BMS cutoff voltage faster than expected during this break-in period. This is a temporary condition — capacity increases with each completed cycle. Complete at least three full charge-discharge cycles before relying on the device for extended clinical use.
The charge indicator on the Accustat never reaches 100% on the first charge after swapping the battery — should I be concerned?
No — the Accustat's charge IC applies a conservative current limit on cells it has not yet profiled, which extends charge time and can prevent the indicator from reaching 100% on the first pass. This is the charge controller protecting the new cell, not a fault. Let the first charge run to completion without interrupting it, even if the indicator stalls. On the second charge cycle the indicator should reach full without issue.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Related Products
Engineered for Performance. Built to Last.
Check out our top-rated selection of reliable products built to last. We offer high-quality options that deliver consistent performance for all your needs.





