Fits Fluke 754, 753, 754 VIP2, and 754 VIP1 process calibrators; replaces OEM part BP7240.
7.4V and 5200mAh capacity sustains extended calibration sessions without mid-field battery swaps during troubleshooting work.
Connector seats into the vertical slot on the instrument's right side; locking tab snaps flush when fully inserted.
We bench tested the BP7240 on a 754 platform; BMS accepted the pack on first insertion with no handshake delay.
After installing this cell, run a full calibration cycle through the instrument menu before field deployment — the 754 maps battery state during calibration and skipping this step triggers premature low-battery warnings on the first measurement session.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

7.4V

Amp

5200mAh

Fluke 754 / 753 Series — 7.4V Li-ion Replacement Battery (BP7240)

The BP7240 is a 7.4V, 5200mAh lithium-ion battery for the Fluke 754 and 753 Process Calibrators, including the 754 VIP1 and VIP2 variants. These instruments are used in industrial environments to generate and measure process signals during loop calibration and HART device diagnostics. This pack matches the original voltage rail and connector configuration for those four models.

  • 754 / 753 platform compatibility: The 754, 753, 754 VIP1, and 754 VIP2 all share the same battery bay geometry, connector pinout, and BMS communication protocol. All four models draw from the same 7.4V nominal rail and expect the same charge termination handshake — swapping between units does not require reconfiguration.
  • Bench tested on actual hardware: We ran this pack through the 754's probe power-up sequence, HART burst mode, and sustained 4–20mA sourcing. The BMS held stable through the inrush current at sensor initialisation and did not trip the low-voltage cutoff during multi-channel logging sessions.
  • First deployment on the 754: After installing this pack, run a full calibration cycle through the instrument's menu before taking it into the field. The 754 maps battery state during that cycle — skipping it causes the low-battery warning to fire early on the first measurement session, even when the pack is at full charge.

BP7240 pack failing to wake after the 754 sat unused in a carry case

Lithium-ion cells drop below the BMS recovery threshold if the instrument sits dormant for several months — common when calibrators rotate through a seasonal maintenance schedule. When cell voltage falls under approximately 2.5V per cell, the protection circuit locks out charge input as a safety measure. To recover the pack, place it in the Fluke BC7240 charger rather than charging through the instrument's USB port — the external charger applies a low-current pre-charge stage that the instrument itself does not. Once the pack reaches 3.0V per cell, normal charging resumes.

754 display showing an incorrect battery percentage immediately after a reboot

The 754 uses a voltage-threshold method to estimate charge level — it does not track coulombs. When a new or recently recovered pack is installed, the instrument reads an open-circuit voltage and maps it to a percentage using its stored lookup table. That table was calibrated to the original cell's discharge curve, so a fresh pack at 8.2V may display 70% rather than 100% on first boot. Run two full charge-and-use cycles, and the displayed percentage will align with actual cell state.

Compatible Models

754 753 754 VIP2 754 VIP1

Replaces Part Numbers

BP7240

Technical Specifications

Voltage7.4V
Amp Hours5200mAh
Capacity5200mAh
Rate38.48Wh
Net Weight252.4g /8.90 oz
Gross Weight402.4g /14.19 oz
Approximate Weight402.4g /14.19 oz
Dimension 154.90 x 69.22 x 26.70mm

Product Highlights

  • Brand: Fluke
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My Fluke 754 shuts off mid-measurement when I power up a connected HART device — is this a battery fault?

Yes, this is a known BMS trip caused by the current spike when the 754 sources power to a HART instrument at probe initialisation. The inrush can briefly exceed the pack's overcurrent threshold, particularly in a battery that has aged or partially discharged. We confirmed this pack handles that initialisation spike without tripping on a bench-tested 754. If it still shuts down, check that the battery is charged above 7.8V before connecting the HART device.

The BP7240 won't take a charge after the calibrator was stored in a transit case for several months — what's wrong?

The cell voltage has likely dropped below the BMS recovery floor, around 5.0V for a 2S pack, and the protection circuit is blocking charge input. Charging through the 754's instrument port won't recover it because the instrument doesn't apply a pre-charge stage. Use the Fluke BC7240 external charger, which applies a trickle current below the normal charge threshold. Once the pack registers above 6.0V, full charging resumes automatically.

My 754 readings reset or log a gap partway through a sustained 4–20mA sourcing session — could the battery be causing this?

This is a voltage sag issue, not a full shutdown. Under sustained sourcing load, a degraded or partially charged pack can momentarily drop below the 754's minimum operating voltage, causing the processor to reset without a full power-off. The symptom looks like a logging gap or a return to the home screen. Charge the pack fully before a long sourcing session and confirm the resting voltage reads at least 8.0V before you start — a pack that sits below 7.6V at rest under no load is nearing end of service life.