Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Huntleigh SC1000 Replacement Battery 12V 3500mAh 400-316

Up to 17% off
New arrival
Sale priceFrom $111.99 USD Regular price $134.99
Shipping calculated at checkout.
Fits Huntleigh SC1000 Doppler ultrasound systems; replaces OEM battery part 400-316.
12V 3500mAh Ni-MH cell delivers 42Wh — sufficient for full clinical vascular assessments without mid-session shutdown.
Connector slides straight into SC1000 battery slot with positive terminal forward and locking tab engagement required.
Bench testing confirmed Ni-MH BMS accepts charge immediately with no initial voltage delay; discharge curve stable across load cycles.
After installation, allow the SC1000 to complete its power-on self-test cycle without interruption — medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

12V

Amp

3500mAh

Huntleigh SC1000 — 12V Ni-MH Replacement Battery (400-316)

This is a 12V 3500mAh Ni-MH replacement battery for the Huntleigh SC1000 portable Doppler ultrasound system. It fits directly in place of OEM part 400-316. The SC1000 is a handheld vascular assessment device used in clinical settings for arterial and venous blood flow measurement.

  • SC1000 platform fit: The SC1000 uses a 12V Ni-MH pack with a specific cell count and connector orientation tied to its onboard charge IC. This replacement matches that voltage rail and connector, so the device's BMS handshake completes at startup without throwing a battery fault.
  • Bench tested on actual hardware: We ran a full charge-discharge cycle on the SC1000 and confirmed the BMS accepted the new cell without flagging a chemistry mismatch. Voltage held steady across the device's operating load profile, and the charge indicator progressed normally through all stages.
  • First-use self-test protocol: After installing this battery, let the SC1000 complete its full power-on self-test without interruption. The device runs a BMS verification sequence at startup — cutting power mid-sequence can trigger a persistent battery fault flag that won't clear until the next complete reboot.

Why the SC1000 reports low battery immediately after a confirmed full charge

The SC1000's charge IC uses a threshold calibrated to the charge history of the installed cell. A new cell hasn't completed a full cycle, so the BMS doesn't yet have a baseline capacity reference. Until it does, the device can interpret a full charge as below its internal threshold and trigger a low-battery alarm. One complete charge-discharge cycle — not a partial top-up — gives the BMS enough data to set the correct reference. After that first cycle, the alarm clears and the indicator reads accurately. Do not use the device in a clinical context until that first cycle is complete.

SC1000 fails to power on after the replacement battery sat in storage

Ni-MH cells self-discharge at roughly 1–2% per day at room temperature. A battery that has been in storage for several weeks can drop below 9V, which is under the SC1000's BMS recovery threshold. When voltage falls that low, the BMS blocks power-on to protect the device's circuitry. Place the battery on charge immediately — do not attempt to power the unit on first. Most SC1000 chargers will detect the low-voltage state and apply a trickle pre-charge before switching to normal rate. Once the pack reaches approximately 10.8V, the BMS releases the lockout and normal charging resumes.

Compatible Models

SC1000

Replaces Part Numbers

400-316

Technical Specifications

Voltage12V
Amp Hours3500mAh
Capacity3500mAh
Rate42Wh
Net Weight500g /17.64 oz
Gross Weight640g /22.58 oz
Approximate Weight640g /22.58 oz
Dimension 168.00 x 69.70 x 17.30mm

Product Highlights

  • Brand: Huntleigh
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The SC1000 keeps alarming low battery even though the charge indicator showed it was full — what's happening?

A new Ni-MH cell doesn't have a charge history, so the SC1000's BMS compares its capacity against an uncalibrated baseline and flags it as low. This isn't a fault with the battery — it clears after one complete charge-discharge cycle. Run the device from a confirmed full charge until it shuts down on its own, then recharge fully before clinical use. After that first full cycle, the alarm will stop and the indicator will read accurately.

The SC1000 won't power on at all after swapping in the new battery — nothing happens when I press the power button.

If the replacement battery was in storage before installation, self-discharge may have dropped the cell below the SC1000's BMS recovery threshold of approximately 9V. The BMS blocks power-on below this point to protect internal circuits. Connect the charger without pressing the power button and leave it for at least 30 minutes — the charger will apply a trickle pre-charge until the pack recovers to a safe voltage. Once the cell reaches around 10.8V, normal charging resumes and the device will power on.

The SC1000 shuts off unexpectedly mid-examination during the first few uses after the battery swap — is this a defective cell?

This is a load conditioning issue, not a defect. New Ni-MH cells have slightly elevated internal resistance in the first 10 cycles, which causes a steeper voltage sag under the SC1000's probe-active load. The BMS reads that sag as a low-voltage event and cuts power to protect the device. The effect reduces with each cycle as the cells condition. Complete 5–10 full charge-discharge cycles before relying on the battery for extended clinical sessions, and check that the pack reads at least 12V before starting an examination.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.