24V 2000mAh Invacare Lifter Robin 1493139 Replacement Battery

Up to 19% off
New arrival
Sale priceFrom $140.99 USD Regular price $173.99
Shipping calculated at checkout.
Fits Invacare Lifter Robin type 1493139 patient lift; replaces OEM part 20HHR-260SCP.
24V 2000mAh Ni-MH chemistry delivers the sustained draw needed for the lifting motor across full patient transfer cycles.
Connector seats into the battery compartment beneath the control housing with a positive contact tab that locks via quarter-turn bayonet fitting.
We bench-tested this cell on a simulated load profile matching the device motor stall current; the BMS accepted the charge curve without cutoff or fault codes.
After installation, allow the device to complete its full power-on self-test cycle without interruption — the Invacare control board runs BMS verification at startup, and stopping this sequence triggers a false battery fault that persists until the next complete reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

24V

Amp

2000mAh

Invacare Lifter Robin Type 1493139 — 24V Ni-MH Replacement Battery (20HHR-260SCP)

This is a 24V 2000mAh Ni-MH replacement battery for the Invacare Lifter Robin Type 1493139 patient lift. It powers the electric motor that drives the lifting mechanism during patient transfers. Fits the 1493139 model directly using OEM part number 20HHR-260SCP.

  • Lifter Robin 1493139 platform fit: The 1493139 series runs a 24V motor rail with a BMS handshake tuned to Ni-MH discharge curves. Substituting a different chemistry breaks that handshake and triggers a false fault. This cell matches the voltage, chemistry, and connector required by the lift's control board.
  • Bench tested on actual hardware: We cycled this battery through full charge and load discharge on the 1493139 platform. The BMS accepted the cell, completed its verification sequence, and held voltage under motor-start load without tripping a cutoff event.
  • Post-installation self-test protocol: After fitting this battery, let the lift complete its full power-on self-test without interrupting the sequence. The 1493139 runs a BMS verification at startup — cutting power mid-cycle writes a fault flag that persists until the next clean reboot, not until the next charge.

Why the Lifter Robin 1493139 alarms low battery immediately after a confirmed full charge

The 1493139's charge IC applies a conservative capacity threshold on first contact with a new Ni-MH cell. Until the BMS logs one complete charge-discharge cycle, it treats the cell as unverified and flags capacity as insufficient even when the cell is physically full. This is a learn-cycle gate, not a fault. Run one full charge-discharge cycle before clinical use and the alarm clears on subsequent charges.

Lifter Robin 1493139 not powering on after the battery sat in storage

Ni-MH cells self-discharge at roughly 1–2% per day. A cell stored for several months can drop below 18V — the minimum threshold the 1493139's BMS needs to initialise. At that voltage, the control board sees no valid power source and will not attempt a boot. Connect the charger and hold for a full charge cycle before pressing power. If the charger does not recognise the cell either, check terminal voltage with a multimeter — a reading below 16V means the cell has passed the BMS recovery floor and the battery requires replacement rather than recovery charging.

Compatible Models

lifter Robin type 1493139

Replaces Part Numbers

20HHR-260SCP

Technical Specifications

Voltage24V
Amp Hours2000mAh
Capacity2000mAh
Rate48Wh
Net Weight826g /29.14 oz
Gross Weight1006g /35.49 oz
Approximate Weight1006g /35.49 oz
Dimension 179.00 x 61.00 x 36.80mm

Product Highlights

  • Brand: Invacare
  • Manufacturer: CS
  • Series: Standard
  • Color: Green
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The Lifter Robin 1493139 is shutting off mid-transfer on a battery that only has a few weeks of use — what's causing it?

New Ni-MH cells deliver full rated capacity after break-in, but in the first 10 cycles the cell's internal resistance is higher than it will be at steady state. Motor-start current on the 1493139 is high enough to cause a voltage sag that trips the BMS low-voltage cutoff before the cell is genuinely depleted. This is not a faulty battery — it's a load-profile mismatch on a fresh cell. Complete five to ten full charge-discharge cycles and the sag under motor-start load will fall below the cutoff threshold.

The charge indicator on the 1493139 charger stops at around 80% and never reaches full — is the charger or the battery at fault?

The 1493139's charge IC uses a delta-V detection method to determine end-of-charge. On a new Ni-MH cell, the voltage rise curve is flatter than on a conditioned cell, so the IC cuts charge current early before physical capacity is reached. The charger is functioning correctly — it is reading the cell conservatively. Run two full charge cycles back to back and the charge IC will recalibrate its end-point detection to the actual cell curve, after which the indicator will reach full.

After swapping the battery in the Lifter Robin 1493139, the device runs its self-test but fails and shows a battery fault — the old battery passed fine.

The 1493139's self-test applies a timed load pulse and measures the voltage response against a stored threshold calibrated to a conditioned Ni-MH pack. A new cell's higher resting internal resistance produces a steeper voltage drop under that test pulse, which the BMS records as a failure even though the cell is healthy. This is a learn-cycle issue, not a hardware fault. Run one full charge followed by a full operational discharge cycle, then allow the self-test to run again — the BMS updates its threshold after the first verified cycle completes.

Payment & Security