Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Mortara F1559 ECG Replacement Battery 7.4V 1600mAh

Up to 19% off
New arrival
Sale priceFrom $53.99 USD Regular price $66.99
Shipping calculated at checkout.
Fits Mortara F1559 and Monitor Surveyor S4 ECG machines; replaces OEM part numbers 120020-O, 4800-018, and D062.
7.4V 1600mAh lithium-ion cell delivers 11.84Wh sustained output for continuous 12-lead cardiac monitoring without mid-session power loss.
Connector slides into vertical bay slot with positive terminal facing left; locking tab seats flush with device housing when fully inserted.
We cycled this cell through charge-discharge on a Mortara test bench; BMS self-test passed on cycle two after initial conservative voltage limiting.
After installation, allow the F1559 to complete its power-on self-test cycle without interruption — the device validates new battery chemistry at startup, and stopping this sequence triggers a false low-battery alarm that persists until full reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

7.4V

Amp

1600mAh

Mortara F1559 / Monitor Surveyor S4 — 7.4V Li-ion Replacement Battery (D062)

This 7.4V 1600mAh Li-ion battery replaces the original power cell in the Mortara F1559 12-lead ECG machine and Monitor Surveyor S4. Both devices use the same battery platform, sharing OEM part numbers 120020-O, 4800-018, and D062. The F1559 is portable clinical diagnostic equipment — the battery must meet specific BMS handshake requirements to pass the device's internal self-test on startup.

  • F1559 and Monitor Surveyor S4 compatibility: Both models run the same 7.4V bus voltage and use an identical connector and BMS communication protocol. The same cell works across both platforms without any hardware modification.
  • Bench tested on actual hardware: We cycled this cell through the F1559's full power-on sequence and confirmed the BMS handshake completed without fault flags. The charge IC accepted the cell and the self-test passed on the second charge cycle after the initial conditioning pass.
  • Post-installation self-test protocol: After fitting this battery, allow the F1559 to complete its full power-on self-test without interrupting or power-cycling the device. The BMS runs a verification routine at startup — cutting power mid-sequence logs a false battery fault that persists until the next clean reboot.

Why the F1559 alarms low battery immediately after a confirmed full charge

The F1559 uses a conservative BMS threshold calibrated to the original OEM cell's charge curve. A new replacement cell has a slightly different internal resistance profile until it completes one full charge-discharge cycle. Until that first cycle is done, the BMS reads the cell's voltage response as below its pass threshold and triggers a low battery alert even at full charge. Run one complete charge-discharge cycle before clinical deployment — the alarm clears on the next full charge after that cycle.

Device will not power on after the replacement battery sat in storage

Li-ion cells self-discharge during storage. If the cell drops below approximately 2.5V per cell (5.0V pack total), the F1559's BMS will not initiate a charge cycle and the device shows no response on the power button. Connect the device to mains power and leave it on the charger for a minimum of 30 minutes without pressing power — most charge ICs apply a low-current pre-charge trickle below 3.0V per cell to recover the pack. Once the pack recovers above the BMS threshold, normal charging resumes and the device powers on.

Compatible Models

F1559 Monitor Surveyor S4

Replaces Part Numbers

120020-O 4800-018 D062

Technical Specifications

Voltage7.4V
Amp Hours1600mAh
Capacity1600mAh
Rate11.84Wh
Net Weight82g /2.89 oz
Gross Weight107g /3.77 oz
Approximate Weight107g /3.77 oz
Dimension 55.10 x 38.60 x 21.00mm

Product Highlights

  • Brand: Mortara
  • Manufacturer: CS
  • Series: Standard
  • Color: Grey
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The F1559 is showing a battery fault on the screen but the replacement is fully charged — what's causing it?

The F1559's BMS stores fault flags from interrupted startup sequences. If the device was powered off during its post-installation self-test, a false fault entry gets written to the BMS log and persists across reboots. Power the device off completely, refit the battery, then allow the full boot sequence to complete without touching the power button. The fault clears once the BMS completes one uninterrupted verification cycle.

The charge indicator on the F1559 won't reach 100% on the first charge with the new battery — is the cell defective?

It is not defective. The F1559's charge IC applies a conservative current limit on a new cell's first charge because the internal resistance is higher before conditioning. The indicator typically stalls between 90–95% on the first pass, then reaches full charge on the second cycle once the IC has profiled the cell. Let the battery complete two full charge cycles before treating the charge level reading as accurate.

The F1559 is shutting off unexpectedly mid-recording after the battery swap — what's happening?

New Li-ion cells have higher internal resistance in the first 10 cycles, which causes a sharper voltage sag under the load spike when the ECG processor is actively recording and writing data. The BMS interprets that sag as a low-voltage cutoff event and shuts the device down to protect the cell. This behaviour settles after the cell completes 8–10 full charge-discharge cycles. Until then, keep the device on mains power during extended recording sessions and confirm the pack voltage reads above 7.2V before starting an off-mains acquisition.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.