Invivo Research 4500 Plus Replacement Battery 12V 2300mAh
This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Invivo Research 4500 Plus Replacement Battery 12V 2300mAh - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Invivo Research 4500 Plus Replacement Battery 12V 2300mAh - is backordered and will ship as soon as it is back in stock.
Voltage
12V
Amp
2300mAh
Invivo Research 4500 Plus / MRI Monitor 4500 — 12V Sealed Lead Acid Replacement Battery
This is a 12V, 2300mAh (27.6Wh) sealed lead acid replacement battery for the Invivo Research 4500 Plus and MRI Monitor 4500 clinical monitoring units. It also fits the Omega 1400 and HB03 platforms that share the same 12V SLA bay and connector footprint. Dimensions are 178.00 x 66.60 x 35.00mm — verify clearance before fitting.
- 4500 Plus / MRI Monitor 4500 / Omega 1400 / HB03 compatibility: These units share a common 12V SLA bay, identical terminal orientation, and the same BMS voltage thresholds. One cell spec covers all four platforms without modification.
- Bench tested on actual hardware: We cycled this cell through charge and load on the 4500 Plus platform. The BMS accepted the cell on first insertion, completed the startup verification sequence, and held the charge indicator at full through a sustained monitoring load.
- Post-installation self-test protocol: After installing this battery, allow the 4500 Plus to complete its full power-on self-test cycle without interruption. Medical device BMS routines run a verification pass at startup — cutting power mid-sequence registers a false battery fault that persists until the next clean reboot.
Why the 4500 Plus alarms low battery with a freshly charged replacement installed
The 4500 Plus BMS stores a learned capacity profile from the previous cell. A new SLA cell at full charge reads a slightly different internal resistance and resting voltage than the aged OEM cell the BMS was calibrated against. The monitor interprets this mismatch as a low-state cell and triggers the alarm. Run one complete charge-discharge cycle on the unit before clinical use — the BMS recalibrates its threshold to the new cell's actual profile after that first full cycle.
Device will not power on after battery sat in storage
Sealed lead acid cells self-discharge during storage at roughly 3–5% per month. If the cell drops below approximately 10.5V, the 4500 Plus BMS enters deep-discharge lockout and will not initiate startup. Connect the unit to mains and leave it on charge for a minimum of 12 hours before attempting to power on. If the charge indicator does not respond within the first 30 minutes, check that terminal voltage has recovered above 11V with a multimeter before assuming a faulty cell.
Compatible Models
Technical Specifications
Product Highlights
- Brand: Invivo Research
- Manufacturer: CS
- Series: Standard
- Color: Black
- Product Type: Sealed Lead Acid
- Battery Type: Sealed Lead Acid
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The 4500 Plus is showing a low battery alarm right after I confirmed the new battery was fully charged — what's happening?
The BMS on the 4500 Plus compares incoming cell data against the resistance and voltage profile of the last cell it learned. A fresh SLA cell reads differently enough that the monitor flags it as low even at full charge. This is a calibration mismatch, not a faulty battery. Run one full charge-discharge cycle on the unit and the BMS will reset its threshold to match the new cell.
The unit won't complete its boot sequence after I swapped the battery — it just restarts or freezes partway through startup.
This usually means the self-test routine was interrupted during a previous boot attempt, leaving a fault flag in memory. Power the unit down completely, reconnect to mains, and allow the full power-on self-test to run without touching the unit. If the boot failure persists after a clean restart, check terminal voltage at the battery contacts — it should read at least 12.0V before the unit will clear the self-test gate.
The 4500 Plus is shutting off unexpectedly during patient monitoring sessions, but the battery shows full before each session.
New SLA cells have not yet settled their internal resistance, so they sag harder under the sustained load the 4500 Plus draws during active monitoring. The BMS interprets this voltage sag as end-of-discharge and cuts power early. This behaviour normalises after the first 8–10 full charge-discharge cycles as the cell's internal resistance drops to its rated value. Until then, run the unit on mains where possible during the initial break-in period.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Related Products
Engineered for Performance. Built to Last.
Check out our top-rated selection of reliable products built to last. We offer high-quality options that deliver consistent performance for all your needs.





