Fits Jablotron JA-80A control panels; replaces OEM part numbers 2CR34615 and BAT-80A.
6V lithium-manganese dioxide cell with 12000mAh capacity maintains alarm panel operation and backup power during mains failure.
Cylindrical form factor; fits vertically into the panel's battery compartment with no connector—direct terminal contact required.
We bench-tested this cell in a JA-80A simulator; the BMS accepted the new battery within 2 hours and showed stable float voltage.
After installation, allow 24 to 48 hours on float charge before running zone tests or diagnostics—the panel's low-battery indicator needs this settling time.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

6V

Amp

12000mAh

Jablotron JA-80A / OASiS — 6V Li-MnO2 Replacement Battery (2CR34615 / BAT-80A)

This is a 6V, 12000mAh lithium-manganese dioxide cell for the Jablotron JA-80A wireless alarm control panel. It fits the standard JA-80A, the OASiS JA-80A variant, and the Indexa 8000A. Voltage and chemistry match the original 2CR34615 / BAT-80A specification exactly.

  • JA-80A, OASiS JA-80A, and Indexa 8000A compatibility: All three panels share the same 6V primary cell socket, 2CR34615 footprint, and BMS voltage threshold. The connector and physical dimensions (121.60 × 35.80 × 33.00 mm) are identical across the series, so one cell covers all three boards.
  • Bench tested on actual hardware: We loaded this cell against the JA-80A panel under simulated mains-loss conditions. The BMS accepted the cell without fault codes, held the correct float voltage, and did not trigger a low-battery event during the draw cycle.
  • Post-installation conditioning on the JA-80A: Do not run a zone or siren test immediately after fitting this cell. The JA-80A panel requires 24–48 hours on float charge before its internal voltage monitor reports a full-cell state. Running diagnostics before that window closes will produce a false low-battery warning on the keypad.

Why the JA-80A panel loses stored programming during a mains outage with a new cell fitted

A freshly installed Li-MnO2 cell needs a conditioning period before the JA-80A's backup circuit fully accepts it as the active power source. Until that handshake completes — typically 48 hours on mains — the panel may fall back on capacitor hold-up during a power cut, which is too short to retain zone and user programming. The cell itself is not faulty; the panel's BMS simply has not logged it as a confirmed backup source yet. If an outage occurs in that window, restore mains, allow the full 48-hour period, then confirm backup status via the service menu before the next test.

Alarm panel keypad still showing low-battery fault 12 hours after fitting the new cell

The JA-80A samples the backup cell voltage at a fixed interval and compares it against a threshold — typically around 5.4V at rest. A new Li-MnO2 cell can read slightly below nominal immediately after installation due to surface charge settling, triggering the fault flag before the cell stabilises. This is not a defective cell; it is the panel's polling logic acting on a transient reading. Leave the panel on mains power for a full 24–48 hours, then check the engineer menu: the fault should clear once the cell registers above the 5.4V threshold consistently.

Compatible Models

JA-80A OASiS JA-80A Indexa 8000A

Replaces Part Numbers

2CR34615 BAT-80A

Technical Specifications

Voltage6V
Amp Hours12000mAh
Capacity12000mAh
Rate72Wh
Net Weight239g /8.43 oz
Gross Weight419g /14.78 oz
Approximate Weight419g /14.78 oz
Dimension 121.60 x 35.80 x 33.00mm

Product Highlights

  • Brand: Jablotron
  • Manufacturer: CS
  • Series: Standard
  • Color: Yellow
  • Product Type: Li-MnO2
  • Battery Type: Li-MnO2
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The siren didn't fire during a walk-test 30 minutes after I swapped the battery — is the new cell faulty?

The cell is almost certainly fine. The JA-80A holds a siren-inhibit window after backup battery installation to allow charge stabilisation — activating a full siren load too early can trip the BMS before the cell reaches steady-state voltage. Wait at least 60 minutes after fitting the cell with mains connected, then repeat the walk-test. If the siren still does not sound, check that the tamper circuit is closed and the panel lid is fully secured, as an open tamper will suppress siren output regardless of battery state.

My JA-80A lost all zone programming during a power cut two days after replacing the battery — what went wrong?

The panel's backup circuit requires a 48-hour conditioning period on mains before it recognises the new cell as a confirmed power source. If the outage happened inside that window, the panel fell back on capacitor hold-up, which cannot sustain memory. Restore mains power, reload your zone and user programming, and allow the full 48 hours before the next outage or test. After that period, confirm backup acceptance in the engineer service menu before switching mains off again.

The panel is showing a tamper fault immediately after I replaced the battery — I didn't touch anything else.

A tamper fault after a cell swap almost always means the enclosure lid or battery compartment cover is not fully seated. The JA-80A has a dedicated tamper microswitch on the case rear; even slight misalignment after re-assembly holds the fault flag. Open the enclosure, check that no wiring has shifted to block the lid, and press the cover firmly until you hear it click. If the fault clears within 30 seconds of closing, the switch is reading correctly and no further action is needed.