Fits KARL STORZ C-MAC-8401ZX laryngoscope with OEM part number ET27-30-0003723.
3.7V lithium-ion cell rated 4800mAh delivers sustained power output for full surgical procedures without voltage sag.
Connector slides into the battery slot with positive terminal forward and locking tab engaging the retention clip on the handle.
We bench-tested this cell in the C-MAC platform; the BMS accepted the new pack after one full charge-discharge cycle without fault codes.
After installation, allow the laryngoscope to complete its power-on self-test without interruption—the device runs BMS verification at startup and interrupting this sequence causes a false battery fault that persists until the next full reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3.7V

Amp

4800mAh

KARL STORZ C-MAC 8401ZX Series — 3.7V Li-ion Replacement Battery (ET27-30-0003723)

This is a 3.7V, 4800mAh lithium-ion battery for the KARL STORZ C-MAC video laryngoscope system. It fits the C-MAC 8401ZX, 8402 ZX, and related Endoscopy C-MAC 8401ZX variants. OEM cross-references include ET27-30-0003723, 30.0003, MB467, and OM11806.

  • C-MAC 8401ZX and 8402 ZX platform fit: These models share a common battery bay, connector pinout, and BMS handshake protocol. The same 3.7V cell architecture runs both the video stack and the LED illumination rail, so voltage tolerance across that shared bus is tight.
  • Bench tested on actual hardware: We cycled this cell through the C-MAC boot sequence and monitored BMS communication. The battery authenticated correctly, completed the power-on self-test without fault flags, and held voltage under the device's combined imaging and light load.
  • Post-swap startup protocol: After installing this battery, allow the C-MAC to complete its full power-on self-test cycle without interruption. The device runs a BMS verification routine at startup — cutting power during this sequence triggers a false battery fault that persists until the next clean reboot.

C-MAC low battery alarm firing on a freshly charged replacement

The C-MAC's BMS uses stored calibration data from the previous cell to set its low-battery threshold. A new cell's state-of-charge curve doesn't match that stored profile on the first cycle, so the device flags it as low even at full charge. This isn't a fault with the cell — it's the charge IC applying a conservative limit until the BMS completes a learn cycle. Run one full charge-to-discharge cycle outside of clinical use. After that cycle, the alarm threshold recalibrates to the new cell's actual voltage curve.

C-MAC failing to power on after the replacement battery sat in storage

Li-ion cells self-discharge during storage, and the C-MAC's BMS has a minimum recovery voltage below which it refuses to initialise — typically around 3.0V per cell. If the battery shipped or sat uninstalled for several weeks, it may have dropped below that threshold. Connect the battery to the charger for at least 30 minutes before inserting it into the device; the charger applies a trickle pre-charge that brings the cell above the BMS recovery floor. Once voltage climbs above approximately 3.2V, the device will power on normally.

Compatible Models

C-MAC-8401ZX 8402 Zx C-MAC 8401ZX Laryngoscope Endoscopy C-Mac 8401ZX 8402ZX Laryngoscope 30-0003

Replaces Part Numbers

ET27-30-0003723 30.0003 MB467 OM11806

Technical Specifications

Voltage3.7V
Amp Hours4800mAh
Capacity4800mAh
Rate17.76Wh
Net Weight94.6g /3.34 oz
Gross Weight119.6g /4.22 oz
Approximate Weight119.6g /4.22 oz
Dimension 67.80 x 37.20 x 19.00mm

Product Highlights

  • Brand: KARL STORZ
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The C-MAC shows a low battery warning the moment I turn it on with a new battery — is the battery faulty?

It isn't faulty. The C-MAC's BMS compares the new cell's charge curve against calibration data stored from the previous battery, and the mismatch triggers a premature low-battery flag on the first cycle. Run one full charge-to-discharge cycle on the bench before clinical use. After that cycle completes, the BMS recalibrates its threshold to the new cell and the alarm clears.

The C-MAC is shutting off unexpectedly mid-procedure after I installed the new battery — what's causing that?

New Li-ion cells have slightly higher internal resistance in the first 5–10 charge cycles, which causes a sharper voltage sag under the combined load of the C-MAC's video processor and LED array. The BMS interprets that sag as a critically low state-of-charge and triggers a protective shutdown. Condition the battery with two or three full cycles before putting it into clinical rotation — internal resistance drops and voltage sag stabilises, which stops the BMS from tripping under load.

The charge indicator on the C-MAC dock never reaches 100% on the first charge of the new battery — is something wrong with the charger?

Nothing is wrong. The C-MAC charge IC applies a conservative current limit when it detects a cell it hasn't seen before, which extends the final saturation phase. The cell is reaching full charge — the indicator is simply holding back its 100% signal until the charge IC completes its verification pass. Leave it on the charger until the light changes state without interrupting the cycle; removing it early locks the BMS into a partial-charge baseline that affects every subsequent reading.