Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Kolsol AT278 Survey Instrument Replacement Battery 3.7V 1800mAh

Up to 19% off
New arrival
Sale priceFrom $38.99 USD Regular price $47.99
Shipping calculated at checkout.
Fits Kolsol AT278 survey instruments; replaces OEM part KS103450.
3.7V, 1800mAh Li-Polymer cell sustains field measurements without mid-session shutdowns.
Connector type and orientation match AT278 slot exactly; no adapter needed.
We bench-tested this pack against the AT278 measurement load—BMS accepted charge cycle and held voltage stable under probe initialization spike.
After installation, run the instrument's full calibration routine before field work; AT278 maps battery state during calibration, and skipping this causes premature low-battery warnings on first measurement session.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3.7V

Amp

1800mAh

Kolsol AT278 — 3.7V Li-Polymer Replacement Battery (KS103450)

This 3.7V, 1800mAh Li-Polymer pack replaces the KS103450 cell in the Kolsol AT278 portable survey and measurement instrument. It fits directly into the AT278 battery bay with no modification. Capacity is 1800mAh (6.66Wh), matching the original specification.

  • AT278 battery bay fit: The AT278 uses a single Li-Polymer cell at 3.7V nominal. The BMS on this device monitors cell voltage closely and will reject packs that fall outside the expected charge curve. This replacement cell matches the original discharge profile so the instrument reads state-of-charge correctly from the first session.
  • Bench tested on actual hardware: We ran the pack through the AT278 probe initialisation sequence and sustained sensor logging cycles. The BMS did not trip on probe power-up current spikes, and voltage held steady under continuous measurement load without triggering the low-battery cutoff.
  • First-use calibration on the AT278: After installing this pack, run a full calibration cycle through the AT278 instrument menu before field deployment. The instrument maps battery state during calibration. Skipping this step causes premature low-battery warnings during your first measurement session, even when the pack is fully charged.

BMS lockout after the AT278 sat unused in a carry case for months

Li-Polymer cells self-discharge slowly during storage. If the AT278 has been sitting unused, the pack voltage can drop below the BMS recovery threshold — typically around 2.5V per cell — and the BMS enters a protective sleep state. At that point, the charger sees no response from the pack and the instrument will not power on. Place the battery on a compatible Li-Po charger with a recovery or trickle mode and allow it to pre-charge at a low current until cell voltage climbs above 3.0V. Once above that threshold, normal charging resumes and the BMS re-initialises.

AT278 display showing erratic battery percentage at reboot after fitting a new pack

The AT278 tracks battery state against a voltage-threshold map calibrated to the original cell. A new pack has a slightly different resting voltage signature, so the percentage indicator can read inconsistently for the first few charge cycles. This is not a fault with the pack. Run two or three full charge-to-discharge cycles through normal instrument use and the indicator will stabilise. If the reading still jumps after three cycles, re-run the calibration routine from the instrument menu to reset the threshold map to the new cell.

Compatible Models

AT278

Replaces Part Numbers

KS103450

Technical Specifications

Voltage3.7V
Amp Hours1800mAh
Capacity1800mAh
Rate6.66Wh
Net Weight35g /1.23 oz
Gross Weight60g /2.12 oz
Approximate Weight60g /2.12 oz
Dimension 51.50 x 34.40 x 10.00mm

Product Highlights

  • Brand: Kolsol
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-Polymer
  • Battery Type: Li-Polymer
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The AT278 powers on fine but shuts off the moment I connect a probe — why?

Probe initialisation draws a short current spike as the sensor module powers up. If the BMS protection threshold is set conservatively, that spike can trigger an overcurrent cutoff before the probe finishes handshaking. We confirmed on the bench that this pack handles the AT278 probe power-up sequence without tripping. If shutdowns persist with a charged pack, check whether the probe connector pins are corroded — a resistive connection raises the instantaneous current draw above what a clean contact would require.

My AT278 is resetting mid-logging session even though the battery indicator shows charge remaining — what's causing that?

Sustained sensor load during a logging session draws more current than the idle display state, which pulls cell voltage down under load even when resting voltage looks healthy. If the loaded voltage dips below the BMS cutoff, the instrument resets. This is distinct from a fully depleted pack — the indicator can still show partial charge because it reads resting voltage, not loaded voltage. Charge the pack to 100% before a long logging session and confirm the charger indicator shows a full charge, not just a top-up from 80%.

This replacement pack will not charge at all after arriving — the AT278 charger light stays off. What do I do?

Li-Polymer packs can drop below the charger's minimum detection voltage during shipping if stored for an extended period. The AT278 charger will not initiate a charge cycle if it cannot detect a pack voltage above roughly 2.5V. Use a standalone Li-Po charger with a recovery or boost mode to pre-charge the cell at 100mA or less until the terminal voltage reaches 3.0V. Once the pack reads above that threshold, place it back in the AT278 charger and the charge cycle will start normally.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.