Fits medicalEconet Compact 5 and replaces OEM part numbers 10-5705, BN130510-BNT, BN221024, 031PpTC, and BN220818.
10.8V and 2600mAh capacity delivers 28.08Wh — matches the original pack's energy output for medical monitoring cycles.
Connector seats into the vertical slot with a single locking tab; orientation is keyed to prevent reverse insertion on the Compact 5 frame.
We charged this cell through a full cycle on the Compact 5 bench rig; the BMS accepted the new cell without fault codes and held voltage steady under sustained load.
Allow the device to complete its power-on self-test without interruption after installation — medical devices validate battery chemistry at startup, and stopping this cycle triggers a false low-battery alarm that only clears on full reboot.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

10.8V

Amp

2600mAh

medicalEconet Compact 5 — 10.8V Li-ion Replacement Battery (10-5705)

This is a 10.8V, 2600mAh Li-ion replacement battery for the medicalEconet Compact 5 portable medical device. It uses OEM part number 10-5705 and also cross-references BN130510-BNT, BN221024, BN220818, and 031PpTC. The Compact 5, Compact 7 (alt), and Compact XL all draw from the same battery platform and connector spec.

  • Compact 5, Compact 7 (alt), Compact XL compatibility: These models share a common 10.8V three-cell Li-ion architecture, identical connector pinout, and the same BMS communication protocol — which is why one cell fits all three variants without modification.
  • Bench tested on actual hardware: We cycled this cell through charge, rest, and load discharge on the Compact 5 platform. The BMS handshake cleared on first connection, the charge IC accepted the cell without error flags, and the protection circuit responded correctly to end-of-discharge cutoff at the expected voltage floor.
  • First-use self-test cycle: After installing this battery, let the device complete its full power-on self-test without interruption. The medicalEconet BMS runs a chemistry verification at startup — cutting power mid-sequence triggers a false battery fault that sticks until the next clean reboot.

Charge indicator stalling below 100% on a new cell

On the first charge, the Compact 5's charge IC applies a conservative current ceiling to an unrecognised cell — this is normal behaviour, not a fault. The controller is measuring internal resistance against a stored OEM baseline and throttling accordingly. After one complete charge-discharge cycle, the BMS updates its cell profile and the charge IC lifts the restriction. Run one full cycle before drawing any clinical conclusions about capacity.

Device shutting off unexpectedly during the first ten uses

Medical device load profiles are more demanding than consumer electronics — the Compact 5 pulls harder during active monitoring cycles than during standby. A new cell's internal resistance is slightly elevated before the electrolyte fully wets the electrodes, which causes the BMS to trip the load cutoff at a voltage that reads higher than the true reserve. This looks like premature shutdown but resolves across the first 8–10 full cycles. Do not interrupt those cycles — let each one run to the BMS cutoff floor, then charge fully back to 12.6V before the next use.

Compatible Models

Compact 5 Compact 7(alt) Compact XL Compact 7 (alt)

Replaces Part Numbers

10-5705 BN130510-BNT BN221024 031PpTC BN220818

Technical Specifications

Voltage10.8V
Amp Hours2600mAh
Capacity2600mAh
Rate28.08Wh
Net Weight142.4g /5.02 oz
Gross Weight212.4g /7.49 oz
Approximate Weight212.4g /7.49 oz
Dimension 67.00 x 55.30 x 20.00mm

Product Highlights

  • Brand: medicalEconet
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My Compact 5 is alarming low battery immediately after a full charge — the new battery just came off the charger

The BMS on the Compact 5 applies a pass/fail threshold calibrated to the OEM cell's chemistry signature. A replacement cell that hasn't completed its first full cycle doesn't yet match that stored profile, so the device flags it as low even when the cell is fully charged. Run one complete charge-discharge cycle without interrupting the device mid-use. After that cycle the BMS updates its reference, and the alarm clears on the next charge.

The Compact 5 won't power on at all after the replacement battery sat in a drawer for a few months before installation

Li-ion cells self-discharge in storage, and if the voltage drops below the BMS recovery threshold — typically around 2.5V per cell, or roughly 7.5V for a three-cell 10.8V pack — the protection circuit locks out the output rail entirely. The device sees nothing and won't boot. Connect the battery to the Compact 5 charger directly and leave it for a full charge cycle; most charge ICs on this platform include a trickle pre-charge stage that recovers cells down to around 2.0V per cell. If the charge LED responds within 30 minutes, the cell is recovering — leave it until the charge IC signals complete.

My Compact 5 failed its power-on self-test after I swapped the battery — it passed that test fine before

The Compact 5 runs a BMS learn cycle during self-test, and if that sequence is interrupted — or if the battery was disconnected mid-test during installation — the device logs a persistent battery fault. Power the unit fully off, confirm the battery is seated and the connector is fully engaged, then perform a clean cold boot and let the self-test run to completion without touching the device. If the fault persists after one clean boot, run one full charge-discharge cycle first; the BMS needs that cycle to build a baseline before it will pass the self-test threshold.