Philips 2040A Mida Medical Battery 6V 3000mAh Ni-MH
This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Philips 2040A Mida Medical Battery 6V 3000mAh Ni-MH - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Philips 2040A Mida Medical Battery 6V 3000mAh Ni-MH - is backordered and will ship as soon as it is back in stock.
Voltage
6V
Amp
3000mAh
Philips 2040A Mida System — 6V Ni-MH Replacement Battery (2045-60700)
This 6V 3000mAh Ni-MH battery replaces the original cell in the Philips 2040A Mida patient monitoring system. It matches OEM part numbers 2045-60700 and M5928. Capacity is 18Wh — identical to factory specification.
- 2040A Mida platform fit: The Mida system uses a 6V Ni-MH cell with a specific connector pinout and BMS handshake. This replacement matches that voltage rail and connector. The BMS recognises the cell chemistry correctly without triggering a foreign-battery fault.
- Bench tested on actual hardware: We cycled this cell through a full charge-discharge sequence and monitored the BMS handshake at startup. The charge controller accepted the cell on first contact and the self-test flag cleared at the end of the initial charge cycle.
- Startup sequence on first install: After fitting this battery, let the Mida system complete its full power-on self-test without interruption. The BMS runs a chemistry verification routine at boot. Interrupting that sequence — even briefly cutting power — sets a battery fault flag that persists until the next complete reboot cycle.
Why the 2040A Mida alarms low battery on a freshly charged replacement
The Mida system's charge IC applies a conservative acceptance threshold on first use. A new Ni-MH cell arrives partially discharged from storage, and the BMS compares its resting voltage against an OEM-calibrated baseline. If the resting voltage sits below that threshold — typically under 5.8V — the system flags a low-battery condition even after a completed charge cycle. Running one full charge-discharge cycle resets the learned capacity register and clears the alarm on subsequent startups.
Mida device shuts off unexpectedly in the first week of use
New Ni-MH cells deliver slightly lower sustained current in the first 8–10 cycles while the electrolyte fully wets the electrode stack. The 2040A Mida's load profile during active patient monitoring draws enough current that an unconditioned cell can sag below the BMS cutoff voltage under peak demand. This triggers an unexpected shutdown that looks like a battery fault but is actually a voltage-sag trip. Cycle the battery three to five times in normal use before relying on it for uninterrupted clinical monitoring — resting cell voltage should stabilise above 6.0V between sessions.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Philips
- Manufacturer: CS
- Series: Standard
- Color: Black
- Product Type: Ni-MH
- Battery Type: Ni-MH
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
My Philips 2040A is alarming low battery right after I installed a fully charged replacement — what's wrong?
The Mida system's BMS compares the new cell's resting voltage against a stored OEM baseline, and a fresh Ni-MH cell often reads below 5.8V at rest even after a full charge. The alarm clears itself once the BMS updates its learned capacity register after one complete charge-discharge cycle. Let the device run down normally, charge it fully again, and the low-battery flag should not reappear. If it does after three cycles, check that the cell is seated firmly and the connector is fully locked.
The 2040A Mida won't power on at all after the old battery sat unused for several months — is the new battery the problem?
No — the issue is the old cell, not a new one. Ni-MH cells self-discharge significantly over several months and can drop below the BMS recovery threshold, which the Mida system treats as an unrecoverable fault. A replacement cell at normal resting voltage resolves this immediately. Fit the new battery, hold the power button for a full 5 seconds, and allow the device to complete its boot and self-test sequence without interruption.
The 2040A failed its self-test after I swapped the battery — the device is flagging a battery error I can't clear. What do I do?
This happens when the BMS learn cycle hasn't completed. The Mida system needs one full charge-discharge pass before it accepts a new cell's capacity profile as valid for clinical use. Power the device on, allow it to run through a complete discharge, then charge it to 100% without interrupting the charge cycle. Once the learn cycle completes, restart the device and the self-test should pass — verify the battery status reads normal before returning the unit to clinical use.