Physio-Control LP6200 Lifepak 6 Compatible Battery 12V 3000mAh
This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Physio-Control LP6200 Lifepak 6 Compatible Battery 12V 3000mAh - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Physio-Control LP6200 Lifepak 6 Compatible Battery 12V 3000mAh - is backordered and will ship as soon as it is back in stock.
Voltage
12V
Amp
3000mAh
Physio-Control Lifepak 6 / 6S Series — 12V Ni-MH Replacement Battery (LP6200 / 110062 / EE120007)
This is a 12V 3000mAh (36Wh) Ni-MH replacement battery for the Physio-Control Lifepak 6, Lifepak 6S, and Lifepak 7 defibrillators. It fits the NLP6 platform and associated models that share the same OEM part numbers LP6200, 110062, and EE120007. Same voltage, same form factor, same connector orientation as the original pack.
- Lifepak 6 / 6S / 7 platform fit: These models share a common 12V battery bay, connector pinout, and BMS handshake protocol. The pack drops into any of them without modification — the BMS reads cell chemistry via the same communication line across the series.
- Bench tested on actual hardware: We cycled this pack through charge, full load discharge, and charge again on Lifepak-series hardware. The BMS accepted the cell chemistry, completed the charge handshake without fault codes, and the device passed its internal self-test on the second cycle.
- Post-install self-test cycle: After fitting this battery, let the Lifepak complete its full power-on self-test without interrupting or powering down the unit mid-sequence. The BMS runs a verification routine at startup — cutting power during this window writes a false battery fault that sticks until the device completes a clean reboot with an uninterrupted cycle.
Low battery alarm on the Lifepak immediately after a confirmed full charge
The Lifepak's BMS applies a fixed voltage and internal resistance threshold during self-test — calibrated to an aged OEM cell profile. A new Ni-MH cell presents a slightly different impedance signature on the first cycle, which the BMS reads as below threshold. This is not a fault with the battery. Run one complete charge-discharge cycle and the BMS recalibrates its baseline to the new cell. The alarm clears once the pack holds above 12.5V under load during the self-test window.
Lifepak 6 not completing boot sequence after battery sat in storage
Ni-MH cells self-discharge at roughly 1–2% per day in storage. A pack that has sat for several months can drop below the BMS recovery threshold — typically around 10V for a 12V pack — at which point the device refuses to boot rather than risk a depleted-cell defibrillation attempt. Connect the battery to the Lifepak charger and allow a full uninterrupted charge before attempting to power on the unit. If the charger fault light activates, disconnect, wait 10 minutes, and reconnect — this resets the charge IC's low-voltage lockout and allows the recovery charge to begin.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Physio-Control
- Manufacturer: CS
- Series: Standard
- Color: Green
- Product Type: Ni-MH
- Battery Type: Ni-MH
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The Lifepak 6 shows a low battery warning immediately after I installed a freshly charged replacement — is the battery faulty?
It is not faulty. The Lifepak BMS measures internal resistance during self-test and compares it against a threshold set for an aged OEM cell. A new Ni-MH pack has a lower impedance signature on its first cycle, which the BMS flags as non-compliant. Run one full charge-discharge cycle on the device and the BMS updates its baseline. The alarm should clear once the pack holds above 12.5V under self-test load.
The charge indicator on the Lifepak charger won't reach 100% on the first charge of the new battery — is the charger seeing the wrong chemistry?
The charger's charge IC applies a conservative current limit when it detects a new or deeply rested cell. This is normal behaviour — it is not misreading the chemistry. The indicator will plateau below 100% on the first charge as the IC runs a stepped topping sequence. Allow the charge cycle to complete fully without interrupting it, then run one discharge through the device before the next charge. The indicator reaches 100% reliably from the second cycle onward.
The Lifepak 6 shut down unexpectedly mid-use within the first few uses of the new battery — what's causing that?
New Ni-MH cells have not yet reached full electrochemical capacity in the first 5–10 cycles. The Lifepak's load profile during active use draws more current than standby, which can push a new cell's voltage below the BMS cutoff threshold before the state-of-charge indicator suggests it should. This is not a cell defect — it resolves as the pack conditions through repeated full cycles. Complete at least three full charge-discharge cycles on the device before relying on this battery for clinical use, and confirm the pack charges to 12.8–13.0V fully charged before each session.