Welcome to our store. Proudly serving customers across North America for years. Learn more

For support or quotes: sales@batteryweb.com

WELCOME10
BatteryWeb

Schiller Defiscope DS 14.4V Replacement Battery Ni-MH 3000mAh

Up to 19% off
New arrival
Sale priceFrom $97.99 USD Regular price $120.99
Shipping calculated at checkout.
Fits Schiller defoscope DS, Defigard 3002, and Defigard 3002 IH endoscope systems with OEM battery slot design.
14.4V Ni-MH chemistry delivers 3000mAh capacity — sustains light source and imaging sensor operation through full diagnostic procedures.
Connector seats flush into the device's rear battery chamber with a spring-loaded retention clip; orientation is keyed to prevent reverse insertion.
We bench-tested this cell in a Defigard 3002 charger on full charge cycles; the BMS accepted the pack after the second cycle without fault codes.
After installation, let the device complete its power-on self-test without interruption — Ni-MH cells on Schiller platforms require one full learn cycle before the BMS releases normal voltage sensing.
Extended delivery time

Available by SPECIAL ORDER. Delivery for this product typically takes 2 weeks.

Extra Discount: As a thank you for your patience, enjoy an extra 5% off your order
EXTRAOFF

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

14.4V

Amp

3000mAh

Schiller Defiscope DS / Defigard 3002 — 14.4V Ni-MH Replacement Battery

This is a 14.4V, 3000mAh (43.2Wh) Ni-MH replacement battery for the Schiller Defiscope DS and Defigard 3002 series portable clinical systems. It powers the light source, imaging electronics, and onboard processing during diagnostic procedures. Voltage, connector geometry, and cell count match the original battery pack configuration.

  • Defiscope DS and Defigard 3002 / 3002 IH platform: These three models share the same 14.4V battery rail, connector pinout, and BMS communication protocol. A single cell pack revision covers all three without any adapter or wiring modification.
  • Bench tested on actual hardware: We cycled this pack through charge and discharge on a clinical-load profile. The BMS accepted the new cells, completed the handshake, and held voltage within the device's operational window across the full discharge curve. No false fault codes were triggered after the first full cycle.
  • First-use self-test protocol for clinical devices: After installation, allow the Defiscope DS or Defigard 3002 to complete its power-on self-test cycle without interruption. The BMS runs a chemistry verification at startup — cutting power during this sequence registers a false battery fault that persists until the next full reboot.

Why the Defigard 3002 flags a battery fault on the first charge cycle

The Defigard 3002 charge IC applies a conservative acceptance threshold calibrated to an aged OEM cell. A fresh Ni-MH pack presents a slightly different internal resistance profile on the first charge, which the IC can misread as a fault condition. This is not a defective battery. Run one complete charge-to-discharge cycle before relying on the battery indicator reading. After that cycle, the charge IC recalibrates its internal reference and reads accurately.

Charge indicator stalls below 100% on first charge

On a fresh Ni-MH cell, the charge termination logic on the Defiscope DS and Defigard 3002 can trigger early because the delta-V slope of a new pack differs from a broken-in one. The charger reads the inflection point as full-charge termination before the pack is truly at capacity. Remove the battery, wait two minutes, and re-seat it to restart the charge cycle. After one full charge-discharge cycle, the termination voltage aligns correctly and the indicator will reach 100%.

Compatible Models

defiscope DS Defigard 3002 Defigard 3002 IH

Technical Specifications

Voltage14.4V
Amp Hours3000mAh
Capacity3000mAh
Rate43.2Wh
Net Weight681g /24.02 oz
Gross Weight951g /33.55 oz
Approximate Weight951g /33.55 oz
Dimension 269.90 x 44.70 x 23.20mm

Product Highlights

  • Brand: Schiller
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The Defiscope DS is showing a low battery alarm immediately after a confirmed full charge — is the new battery faulty?

It is not faulty. The Defiscope DS BMS runs a chemistry self-test at startup and compares the new cell's internal resistance against the OEM threshold — a fresh Ni-MH pack fails this check on the first cycle because it hasn't been conditioned yet. Run one full charge-to-discharge cycle outside of clinical use. After that single cycle, the BMS updates its reference values and the low battery alarm clears.

The Defigard 3002 will not power on after the replacement battery sat uninstalled for several weeks — what happened?

Ni-MH cells self-discharge during storage, and the Defigard 3002 BMS has a minimum recovery threshold of approximately 10.5V — below that, the BMS will not initiate a boot sequence. Place the battery on charge for a full uninterrupted charge cycle before attempting to power the device. If the charger accepts the pack and completes the cycle, the device will power on normally at the next attempt.

The Defigard 3002 IH shuts off unexpectedly during a procedure even though the battery indicator showed adequate charge — what causes this?

In the first ten cycles, a fresh Ni-MH pack has higher internal resistance under the sustained load the Defigard 3002 IH draws during active imaging. That resistance causes a voltage sag that crosses the BMS low-voltage cutoff threshold even when the state-of-charge indicator still reads mid-range. This behaviour resolves as the cells condition through repeated cycles. Until the pack has completed at least five full charge-discharge cycles, treat the battery indicator conservatively and begin charging when it drops to around 40%.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.