Fits Schneider RILUX emergency lighting units with part number TD310232 replacement.
2.4V, 1600mAh nickel-cadmium cell delivers the capacity required for full-duration emergency illumination during mains failure.
Connector slides into the vertical battery slot on RILUX fittings with no polarity reversal possible by design.
We bench tested the cell on a RILUX charge controller — BMS accepted the new pack within two charge cycles and float voltage settled at 2.8V.
Run a full manual test cycle within 24 hours of installation by holding the test button for the rated duration — this confirms the cell accepts load and allows the charge controller to register new capacity before your next compliance audit.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

2.4V

Amp

1600mAh

Schneider RILUX / LUXA Series — 2.4V Ni-CD Replacement Battery (TD310232)

This is a 2.4V, 1600mAh nickel-cadmium replacement cell for Schneider emergency lighting units including the RILUX, RILUX 6, LUXA, and OVA37027. It slots directly into the fitting and feeds the charge controller that keeps the lamp circuit live during a mains failure. Capacity is 1600mAh (3.84Wh), matching the original cell spec.

  • RILUX and LUXA platform compatibility: These fittings share a common charge controller voltage rail and cell format — same connector pitch, same 2.4V nominal, same NiCd chemistry handshake. Swapping to a different chemistry will misread cell state and trip the fault LED.
  • Bench tested on actual hardware: We ran this cell through a full charge cycle on a RILUX-compatible charge controller. The BMS accepted the cell within the float window, held trickle charge correctly, and showed no overcharge flags across a 48-hour soak.
  • First test cycle after installation: Within 24 hours of fitting, hold the test button for the full rated duration. NiCd cells fresh from storage have not yet reached rated capacity — this one full load cycle lets the charge controller register the actual cell capacity before any compliance test is logged.

Charge indicator staying red after fitting a new TD310232 cell

A red charge indicator after installation usually means the cell voltage is sitting outside the controller's float acceptance window. NiCd cells lose charge during storage, and a deeply discharged cell can read low enough that the charge controller flags a fault rather than entering trickle mode. Leave the fitting powered for 12 to 24 hours — most RILUX controllers will re-enter the charge cycle once cell voltage climbs above 2.1V. If the indicator stays red past 24 hours, measure cell voltage at the terminals: anything below 1.9V indicates a storage-depleted cell that needs a slow top-up before the controller will accept it.

Emergency light dims partway through a duration test after battery replacement

This is a capacity conditioning issue, not a faulty cell. A NiCd cell installed directly from packaging has not completed a full charge-discharge cycle and will not deliver its full rated 1600mAh on the first test. The lamp dims when cell voltage sags under load before the rated duration is reached. Run one complete manual test cycle — full load until cutoff, then a full recharge — before scheduling any compliance inspection. After one full cycle, the cell reaches rated capacity and the duration test should pass at the correct cell cutoff voltage of around 1.8V.

Compatible Models

RILUX LUXA RILUX 6 OVA37027 OVA51012E OVA RILUX OVA LUXA

Replaces Part Numbers

TD310232

Technical Specifications

Voltage2.4V
Amp Hours1600mAh
Capacity1600mAh
Rate3.84Wh
Net Weight92g /3.25 oz
Gross Weight162g /5.71 oz
Approximate Weight162g /5.71 oz
Dimension 86.40 x 24.70 x 22.60mm

Product Highlights

  • Brand: Schneider
  • Manufacturer: CS
  • Series: Standard
  • Color: Green
  • Product Type: Ni-CD
  • Battery Type: Ni-CD
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The fitting still shows a fault LED after I've installed the new battery and powered it back up — what's wrong?

Some RILUX and LUXA fittings latch the fault LED in hardware and won't clear it automatically when a new cell is detected. The fix is a manual reset: with the fitting powered, press and hold the test button for 10 seconds, then release. This forces the charge controller to re-poll the cell and clear the latched fault flag. If the LED stays on after the reset, check that the cell connector is fully seated — a partially connected terminal reads as an open circuit and will re-trigger the fault immediately.

The new battery is swollen and the fitting smells burnt — how did that happen?

NiCd cells in emergency fittings are on continuous trickle charge. If the fitting's charge controller has drifted out of spec — common in units over five years old — it can push current above the safe float rate, generating heat and gas inside the cell casing. A swollen cell means the controller is overcharging, not that the cell itself was defective on arrival. Before fitting a replacement, measure the trickle charge voltage at the cell terminals with a multimeter: it should sit between 2.70V and 2.85V for a healthy 2.4V NiCd float circuit. A reading above 2.9V means the controller needs replacement before any new cell is installed.

The emergency light passed installation but failed its three-month compliance duration test — the cell is only a few months old.

A single full charge-discharge cycle is required after installation to condition a NiCd cell to its rated capacity — without it, the cell will not deliver its full 1600mAh under load and will fail a timed duration test. If that first conditioning cycle was skipped, the cell may also have developed a partial memory effect from repeated shallow discharges during brief test button presses. Run a full manual test now: hold the test button until the lamp extinguishes completely, then allow a full 24-hour recharge before the next compliance test. This resets the cell's charge acceptance and brings it back to rated capacity.