Stahl ECOLUX 6608/5 Replacement Battery 6V 8000mAh Ni-CD
This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Stahl ECOLUX 6608/5 Replacement Battery 6V 8000mAh Ni-CD - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Stahl ECOLUX 6608/5 Replacement Battery 6V 8000mAh Ni-CD - is backordered and will ship as soon as it is back in stock.
Voltage
6V
Amp
8000mAh
Stahl ECOLUX 6608/5 — 6V Ni-CD Replacement Battery (118017)
This is a 6V 8000mAh Ni-CD replacement battery for the Stahl ECOLUX 6608/5 emergency lighting unit. It matches OEM part number 118017 and fits directly into the original fitting. The ECOLUX 6608/5 is a maintained or non-maintained emergency exit light — this battery is the cell that powers the lamp during a mains failure event.
- ECOLUX 6608/5 fit: The 6608/5 uses a fixed 6V Ni-CD cell with specific float charge acceptance requirements. The charge controller in this fitting monitors cell voltage and will not register a healthy state until the cell climbs into its float acceptance window — a mismatched cell type or voltage rating trips a fault condition immediately.
- Bench tested on actual hardware: We ran this cell through a full charge cycle on a Ni-CD controlled charger and confirmed the BMS accepted the float voltage without fault. Load discharge confirmed the cell held capacity through a full simulated test duration without voltage collapse.
- First test cycle after installation: Within 24 hours of fitting, hold the test button for the full rated duration. This forces the charge controller to register the new cell's capacity baseline before the next scheduled compliance test. Skipping this step can cause the fitting to log a duration failure on its first automatic test.
Charge indicator staying red after fitting a new 118017 cell
The ECOLUX 6608/5 charge controller monitors float voltage to confirm the cell is healthy. A new Ni-CD cell that has been in storage will often arrive at a suppressed resting voltage — sometimes below the controller's float acceptance threshold. The controller reads this as a fault and holds the red LED. Allow the fitting to trickle charge the new cell for 24 hours undisturbed; most cells recover to float voltage within that window and the indicator shifts to green. If the LED stays red beyond 48 hours, measure the cell terminal voltage — it should be climbing toward 7.2V on a 6V Ni-CD pack under charge.
Emergency light dims partway through a duration test after battery replacement
A new Ni-CD cell that hasn't completed a full conditioning cycle will show voltage sag under sustained load before the test duration ends. This is not a cell defect — it reflects that the cell hasn't yet reached its rated capacity from storage. The fix is one complete charge-discharge-charge cycle: run the test button to full discharge, then charge uninterrupted for a full cycle before the next test. After that cycle, the cell's available capacity aligns with its 8000mAh rating and voltage holds stable across the full test duration.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Stahl
- Manufacturer: CS
- Series: Standard
- Color: Black
- Product Type: Ni-CD
- Battery Type: Ni-CD
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The ECOLUX 6608/5 passed its duration test before the battery change but now fails it — what's happening?
A fresh Ni-CD cell needs at least one full charge-discharge cycle before it delivers its rated capacity. Out of storage, the cell's active material hasn't been fully conditioned, so voltage collapses earlier than the test duration requires. Run a deliberate manual test to full discharge, then charge the fitting uninterrupted for a full cycle. After that single conditioning cycle, the cell should hold voltage across the full rated duration.
The fitting's fault LED is still showing after I've installed the new 118017 battery and confirmed it's seated correctly — why won't it clear?
Some ECOLUX fittings latch a fault LED in firmware and don't auto-clear it when a new cell is detected. The fault was logged against the old cell and the controller needs a manual reset to clear it. On the 6608/5, hold the test button for three seconds while on mains power — this forces the controller to re-poll the cell and clear the latched fault. If the LED re-trips immediately after release, check that the cell connector is fully seated and the terminal voltage reads above 6V.
I found the old Ni-CD cell had swollen inside the ECOLUX 6608/5 fitting — is this a sign the new replacement will do the same thing?
Swelling in Ni-CD emergency light cells is caused by years of continuous trickle charge at elevated temperature inside a sealed fitting — not by a defect in the cell itself. Heat from the lamp assembly and the fitting's enclosure raises the cell temperature above the safe trickle charge threshold, and prolonged overcharge produces gas that deforms the casing. The replacement cell faces the same environment, so check that the fitting's charge current is within spec for a 6V 8000mAh Ni-CD cell — the float charge current should not exceed 80mA at ambient temperature. If the fitting runs hot, consider mounting orientation and ventilation around the enclosure.