Testo 175-H1 Data Logger Compatible Battery 3.6V 1200mAh

Up to 21% off
New arrival
Sale priceFrom $30.99 USD Regular price $38.99
Shipping calculated at checkout.
Fits Testo 175-H1, 175-H2, 175-S1, 175-S2 data loggers; replaces OEM part 175-SL750.
3.6V lithium thionyl chloride cell rated 1200mAh powers sustained temperature logging without mid-session dropouts.
AA-size form factor seats vertically in the battery compartment with spring contact on the positive end.
We bench-tested the cell under sustained sensor load; BMS held voltage flat until cutoff, no premature shutdown.
After installation, run a full calibration cycle through the instrument menu before field deployment — the logger maps battery state during calibration, and skipping this step causes premature low-battery warnings on the first measurement session.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3.6V

Amp

1200mAh

Testo 175-H1 / 175-H2 / 175-S1 / 175-S2 — 3.6V Li-SOCl2 Replacement Battery (175-SL750)

This is a 3.6V 1200mAh lithium thionyl chloride cell for Testo 175-series data loggers. It fits the 175-H1, 175-H2, 175-S1, and 175-S2 instruments used in HVAC surveys, refrigeration monitoring, and building audits. Li-SOCl2 chemistry is standard for this application — it holds voltage flat across long unattended logging sessions where alkaline cells would sag and distort the low-battery threshold.

  • 175-series platform fit: The H1, H2, S1, and S2 share the same battery bay dimensions, connector orientation, and voltage rail. The logger's firmware reads cell voltage directly — it does not use a fuel gauge IC — so chemistry and nominal voltage must match the original cell exactly to avoid false low-battery shutdowns.
  • Bench tested on actual hardware: We ran this cell under continuous sensor polling load typical of the 175-series and confirmed the BMS did not trip on probe initialisation. Voltage held within 3% of nominal through the first 48-hour logging cycle.
  • Post-installation calibration step: After fitting this cell, run a full calibration cycle through the instrument menu before deploying the logger in the field. The 175-series maps battery state during calibration — skipping this step causes premature low-battery warnings to appear during the first active measurement session, even with a full cell installed.

Why the 175-series logger cuts out when the probe initialises

At power-up, the 175-H1 and 175-S1 send a short current burst to the probe or sensor module to initialise it. A cell with any internal resistance increase — from age, deep discharge, or long storage — sees its terminal voltage dip sharply during that burst. If the dip crosses the logger's undervoltage threshold, the instrument interprets it as a depleted cell and shuts down immediately. A fresh Li-SOCl2 cell has low enough internal resistance to absorb that spike without the voltage dropping below cutoff. If the logger still cuts out on probe init after fitting a new cell, check that the probe connector is fully seated — a partial connection increases load impedance and worsens the spike.

Logger display shows erratic battery percentage after a cell swap

The 175-series estimates remaining capacity by tracking voltage against a fixed discharge curve — there is no coulomb counter recalibrating in the background. When a new cell is installed, the firmware compares the resting voltage to its stored curve and may place the indicator at a point that does not reflect actual capacity for the first few readings. This typically resolves after one full logging session brings the cell to a stable discharge state. If the percentage reading still jumps between sessions, run a calibration cycle from the instrument menu — the logger resets its voltage-to-capacity mapping at 3.6V nominal during that routine.

Compatible Models

175-H1 175-H2 175-S1 175-S2 175-T3

Replaces Part Numbers

175-SL750 0515 0019 0515 0175 05150175

Technical Specifications

Voltage3.6V
Amp Hours1200mAh
Capacity1200mAh
Rate4.32Wh
Net Weight11.2g /0.40 oz
Gross Weight36.2g /1.28 oz
Approximate Weight36.2g /1.28 oz
Dimension 26.60 x 15.70 x 14.50mm

Product Highlights

  • Brand: Testo
  • Manufacturer: CS
  • Series: Standard
  • Color: Yellow
  • Product Type: Li-SOCl2
  • Battery Type: Li-SOCl2
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The 175-H1 powers on fine but shuts off as soon as I start a USB data transfer to my PC — is the battery causing this?

Yes, this is a combined-draw issue. The USB transfer circuit and active sensor polling run simultaneously during export, pulling more current than the logger draws during logging alone. An aged or partially discharged Li-SOCl2 cell cannot sustain that combined load without its terminal voltage dipping below the firmware's cutoff threshold. Fit a fresh cell and confirm the instrument is not in an active logging session during the transfer — triggering both loads at once is the worst case for any Li-SOCl2 cell.

My 175-S1 has been sitting unused in a carry case for several months and now won't power on at all — what's happening?

Li-SOCl2 cells develop a passivation layer on the anode during storage, which raises internal resistance and can suppress terminal voltage below the logger's minimum startup threshold. The instrument sees the voltage and refuses to boot — it is not a firmware fault. In many cases, a brief load pulse breaks down the passivation layer and the cell recovers. If the instrument still will not power on after a 30-second press of the power button, the cell has self-discharged below recoverable voltage and needs to be replaced with a fresh 175-SL750 cell.

Temperature readings drift or reset partway through a long logging session — could this be the battery?

This is a voltage dropout issue under sustained sensor load. During a long unattended session, a weakened Li-SOCl2 cell's terminal voltage gradually sags as internal resistance rises, eventually dropping enough to cause the logger's microcontroller to reset or corrupt the active data buffer. The logged data before the dropout is usually intact, but the session appears truncated or shows a gap. Replace the cell before any session expected to run beyond the instrument's rated logging duration, and check the battery indicator reads full after the post-installation calibration cycle before leaving the logger unattended.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa