Fits Chauvin Arnoux C.A 6116N and C.A 6117 power quality analyzers, replacing OEM part 693942A00.
10.8V 5200mAh lithium-ion pack delivers the sustained current draw needed for harmonics analysis and extended field survey sessions without voltage sag.
Connector slides straight into the battery slot with a positive locking tab — ensure the tab seats fully before closing the instrument case.
We ran this pack through a full measurement cycle on the C.A 6116N; BMS accepted the cell at power-on with no initialization fault codes.
After installing, run a full calibration cycle through the instrument menu before field deployment — the analyzer maps battery state during calibration and skipping this step causes premature low-battery warnings during measurement sessions.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

10.8V

Amp

5200mAh

Chauvin Arnoux C.A 6116N / C.A 6117 — 10.8V Li-ion Replacement Battery (693942A00)

This 10.8V 5200mAh (56.16Wh) lithium-ion pack replaces OEM part 693942A00 in the Chauvin Arnoux C.A 6116N and C.A 6117 power quality analyzers. Both instruments run the same battery bay, connector pinout, and BMS communication protocol. Capacity figures come from the product data — not web estimates.

  • C.A 6116N and C.A 6117 shared platform: Both analyzers use the same 10.8V three-cell series configuration and the same data lines between the pack and the instrument's power management board. One battery fits both because the BMS handshake, connector keying, and voltage thresholds are identical across that instrument generation.
  • Bench tested on actual hardware: We cycled this pack through the C.A 6116N's sustained logging draw and the higher current spike that occurs when the clamp probe module initialises. The BMS handled both without nuisance cutoff, and cell balancing remained stable through five full discharge-charge cycles.
  • Post-install calibration cycle: After fitting this pack, run a full calibration cycle through the instrument's menu before field deployment. The C.A 6116N maps battery state during that routine — skipping it causes the instrument to display premature low-battery warnings on the first measurement session, even with a fully charged pack.

BMS lockout after the C.A 6116N sat unused in a carry case for months

Lithium-ion packs left discharged for extended periods drop below the BMS recovery threshold — typically around 2.5V per cell for a 10.8V three-cell pack. When that happens, the protection circuit locks out charge current entirely, and the instrument shows nothing or a flashing error on connection. The fix is a slow pre-charge pulse from a compatible charger that forces the cells back above the recovery floor before normal charging resumes. Once cell voltage climbs above approximately 9V pack-total, the BMS re-enables the charge path and normal charging proceeds.

Readings resetting or dropping out mid-logging session

This is a voltage sag failure, not a calibration fault. When the analyzer sustains a heavy sensor load — simultaneous clamp input, display backlight, and active data logging — total current draw climbs enough to pull pack voltage below the instrument's brownout threshold, triggering a reset. A degraded or partially charged original pack fails this load; a fresh 5200mAh pack at full charge holds the voltage rail above that threshold. Before a long logging session, charge the pack fully and confirm the instrument's battery indicator reads 100% at startup.

Compatible Models

C.A 6116N C.A 6117

Replaces Part Numbers

693942A00

Technical Specifications

Voltage10.8V
Amp Hours5200mAh
Capacity5200mAh
Rate56.16Wh
Net Weight346.4g /12.22 oz
Gross Weight526.4g /18.57 oz
Approximate Weight526.4g /18.57 oz
Dimension 127.25 x 86.80 x 28.20mm

Product Highlights

  • Brand: Chauvin Arnoux
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The C.A 6116N powers on fine but shuts itself off the moment I connect the clamp probe — why?

The clamp probe module draws a short initialisation spike when it powers up, and if the pack's BMS interprets that spike as an overcurrent event, it trips the protection circuit and cuts output. We saw this on the bench with partially depleted packs — the BMS trip threshold tightens as cell voltage falls. Charge the pack fully before connecting any probe module, and let the instrument boot completely before plugging in the clamp. A full charge keeps cell voltage high enough that the spike stays within the BMS's acceptable window.

New pack installed, instrument shows battery percentage jumping around erratically at every reboot — is the pack faulty?

It is not faulty — the instrument's voltage-threshold indicator is recalibrating itself to the new cell's discharge curve. The C.A 6116N reads pack state by sampling voltage at intervals, and a new cell has a slightly different voltage-to-state relationship than the worn original. Run two or three full discharge-and-charge cycles through the instrument, and the percentage display stabilises. Skip the calibration cycle in the instrument menu first — that step accelerates the recalibration.

The pack charges normally on the charger but will not charge at all when connected through the instrument's USB-C port while transferring data — what is happening?

USB data transfer and active measurement load together pull more current than the instrument's internal charge circuit is rated to supply simultaneously. The firmware drops charging priority to protect the measurement session, so the pack neither gains nor holds charge during that combined draw. Transfer data with the instrument idle — close any active logging session first — and charge the pack separately through the dedicated charger port. Once the transfer is complete, reconnect via the charger path and charging resumes normally.