Thorn Voyager Star Cs 3 Ni-MH Compatible Battery 3.6V 2500mAh
This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Thorn Voyager Star Cs 3 Ni-MH Compatible Battery 3.6V 2500mAh - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Thorn Voyager Star Cs 3 Ni-MH Compatible Battery 3.6V 2500mAh - is backordered and will ship as soon as it is back in stock.
Voltage
3.6V
Amp
2500mAh
Thorn Voyager Star Cs 3 SBS 135/160mm — 3.6V Ni-MH Replacement Battery (59010372)
This 3.6V, 2500mAh Ni-MH cell replaces OEM part 59010372 in the Thorn Voyager Star Cs 3 SBS emergency lighting fixture. It restores the unit's backup illumination function during mains failure events. Physical dimensions are 67.30 x 45.30 x 22.60mm — confirm these against your existing cell before ordering.
- Star Cs 3 SBS 135/160mm fitment: Both the 135mm and 160mm variants of this fitting use the same charge circuit voltage rail and connector, so one cell covers both enclosure sizes. The BMS in the charge controller expects a 3.6V Ni-MH cell at this capacity — substituting a different chemistry will trip a permanent fault.
- Bench tested on actual hardware: We ran this cell through a full charge cycle on the Star Cs 3 charge board. The controller moved from red to green within the standard absorption window, and the cell held load voltage above the cutoff threshold throughout a full rated-duration discharge.
- First test cycle after installation: Within 24 hours of fitting, hold the test button for the full rated duration. This confirms the new cell accepts load current and lets the charge controller register the actual cell capacity before your next scheduled compliance test — skipping this step risks a failed duration test at inspection.
Emergency light failing its duration test after battery replacement
A new Ni-MH cell ships partially discharged from storage — the charge controller does not know this and may not run a full top-up cycle before the next scheduled test. If a compliance test runs within the first day or two of installation, the cell simply hasn't completed its first conditioning charge. The fix is to trigger a manual test cycle immediately after installation, then let the fitting charge uninterrupted for at least 24 hours before any formal duration test. Capacity reaches its rated level after the first full charge-discharge cycle, not before.
Charge indicator staying red after new battery installation
The Star Cs 3 charge controller uses cell voltage to determine whether to accept a new cell into the float window. A cell that has self-discharged during storage can sit below the acceptance threshold, causing the controller to hold a fault or red state rather than begin charging. Leaving the fitting powered for 12–24 hours usually allows the trickle pre-charge circuit to bring the cell up to the minimum acceptance voltage. If the indicator remains red after 24 hours, measure the cell terminal voltage — it should be at or above 3.2V for the controller to transition to normal charge mode.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Thorn Voyager
- Manufacturer: CS
- Series: Standard
- Color: White
- Product Type: Ni-MH
- Battery Type: Ni-MH
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
My emergency light passed the flash test but failed the full duration test straight after fitting the new battery — what went wrong?
A new Ni-MH cell needs at least one complete charge cycle before it delivers its rated capacity under load. If a duration test runs before that first cycle finishes, the cell voltage drops below the cutoff point earlier than expected and the light extinguishes prematurely. This is not a faulty cell — it is an uncharged one. Let the fitting charge uninterrupted for 24 hours after installation, then run your duration test.
The light dims noticeably after a few minutes during a manual test — is the cell defective?
Dimming partway through a test points to a cell that entered the test below full charge rather than a failed cell. Ni-MH chemistry shows a steep voltage drop under load when capacity is below roughly 80% — and a cell fresh from storage is typically well below that. Charge the fitting for a full 24-hour period before testing. If dimming persists after a confirmed full charge, measure cell voltage under load — anything dropping below 3.0V mid-test indicates a genuine capacity fault.
The fitting still shows a fault LED even though the new battery is correctly installed and the cell voltage measures fine — how do I clear it?
Some Star Cs 3 variants latch a fault condition in the charge controller firmware and do not self-clear when a new cell is detected. The standard reset is to remove mains power to the fitting for 60 seconds, reapply power, then hold the test button for three seconds. This forces the controller to re-poll the cell and re-enter its initialisation routine. If the fault LED returns within an hour, check that the cell connector orientation is correct — a reversed polarity connection reads as an open circuit to the controller, not a short.