Fits Topcon GTS-600, GTS-602, GTS-601, GTS-605 total stations; replaces OEM battery BT-50Q.
7.2V, 2700mAh Ni-MH pack delivers stable voltage under sustained field measurement loads without mid-session dropout.
Connector slots vertically into battery door on instrument rear; locking tab seats flush when fully inserted.
We bench-tested this cell through full discharge cycles on GTS-602 hardware; BMS discharged evenly without cutoff anomalies.
After installing, run a full calibration cycle through the instrument menu before field deployment — the GTS platform maps battery state during calibration, and skipping this step causes premature low-battery warnings on the first measurement session.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

7.2V

Amp

2700mAh

Topcon GTS-600 Series — 7.2V Ni-MH Replacement Battery (BT-50Q)

This is a 7.2V, 2700mAh Ni-MH replacement for the Topcon BT-50Q battery pack. It fits the GTS-600, GTS-601, GTS-602, and GTS-605 total stations — the series used across construction layout, civil engineering, and land surveying. Capacity is 19.44Wh, matching the original specification.

  • GTS-600 series compatibility: The GTS-600, GTS-601, GTS-602, and GTS-605 share the same battery bay geometry, voltage rail, and connector pinout. All four models draw from the same 7.2V bus to power the EDM, angle encoders, and display simultaneously. One pack fits all four without modification.
  • Bench tested on actual hardware: We cycled this pack through full charge and discharge on a GTS-series unit and monitored the BMS response during EDM activation — the highest instantaneous draw event. The pack held voltage above the cutoff threshold through repeated measurement bursts without triggering a protection event.
  • First-use calibration on the GTS-600: After installing this pack, run a full calibration cycle through the instrument menu before heading to site. The GTS-600 maps battery state during calibration — skip this step and the low-battery warning will fire early on your first measurement session, even with a full charge.

EDM pulse triggering BMS cutoff on the GTS-600

The electronic distance measurement module on the GTS-600 draws a sharp current spike every time it fires a pulse toward a prism. On a degraded or deeply discharged Ni-MH pack, this spike can push the cell voltage below the BMS protection threshold for a fraction of a second — enough to trigger a shutdown. A new pack with full cell capacity absorbs this spike without the voltage rail collapsing. If the instrument is shutting off during distance measurements but not during angle-only readings, the battery is the first thing to replace.

GTS-600 not recognising a new pack after it sat unused for months

Ni-MH cells self-discharge over storage. If this pack sat in a warehouse or a carry case for an extended period, cell voltage may have dropped low enough for the BMS to enter sleep mode. The instrument then sees no response on the battery communication line and will not power on. Put the pack on a dedicated Ni-MH charger — not the instrument's internal charger — and let it run a full charge cycle. Once cell voltage recovers above approximately 6.0V, the BMS wakes and the instrument will recognise the pack normally.

Compatible Models

GTS-600 GTS-602 GTS-601 GTS-605

Replaces Part Numbers

BT-50Q

Technical Specifications

Voltage7.2V
Amp Hours2700mAh
Capacity2700mAh
Rate19.44Wh
Net Weight297.2g /10.48 oz
Gross Weight367.2g /12.95 oz
Approximate Weight367.2g /12.95 oz
Dimension 93.60 x 69.20 x 55.10mm

Product Highlights

  • Brand: Topcon
  • Manufacturer: CS
  • Series: Standard
  • Color: Yellow
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My GTS-600 shuts off the moment I fire a distance measurement, but it stays on fine during angle readings — what's happening?

The EDM pulse draws a sharp current spike that a weak or partially discharged pack cannot sustain without the voltage rail dropping below the BMS cutoff. Angle readings use far less current, so the instrument stays on — but the EDM fires it straight into a protection event. Charge the pack fully before the next session and run the instrument's calibration cycle so it can map battery state accurately. If the shutdown persists on a fully charged pack, the cells have degraded past recovery and the pack needs replacing.

The GTS-600 displays an inconsistent battery percentage — it shows 80% at startup, then jumps to 20% after two setups. What causes that?

The GTS-600 estimates charge state by reading the battery voltage at startup and comparing it against a stored threshold table. A new Ni-MH pack has a slightly different voltage curve than the original cells, so the first few readings will be off until the instrument recalibrates its reference. Run two full charge-discharge cycles and put the instrument through its calibration menu each time. After that, the percentage readout stabilises against the new pack's actual voltage curve.

This replacement pack charged overnight but still won't power the GTS-600 on — is the pack dead or is something else wrong?

If the pack sat in storage for months before use, the cells may have self-discharged below the BMS recovery threshold, and the instrument's internal charger may not push enough voltage to wake the BMS from sleep. Pull the pack and charge it on a standalone Ni-MH charger capable of delivering a recovery charge. Once cell voltage climbs back above approximately 6.0V, the BMS exits sleep mode and the instrument will power on normally.