Fits Trismed VITAPIA7000K (Type7012K) patient monitor, replacing OEM part 855183P.
7.4V, 3700mAh lithium-ion cell delivers full capacity for continuous vital signs monitoring in clinical settings.
Connector seats into the monitor's rear battery slot with positive terminal forward and locking tab engaged.
We bench-tested this cell against the OEM BMS profile — the device accepted the new pack on first insertion with no fault codes during charging.
After installation, allow the device to complete its power-on self-test cycle without interruption — medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

7.4V

Amp

3700mAh

Trismed VITAPIA7000K (Type7012K) — 7.4V Li-ion Replacement Battery (855183P)

This 7.4V, 3700mAh lithium-ion battery replaces part number 855183P in the Trismed VITAPIA7000K (Type7012K) patient monitor. It fits the portable vital signs monitoring platform used in clinical environments for continuous patient health tracking. Voltage, connector, and BMS communication match the original cell specification.

  • VITAPIA7000K platform fit: The Type7012K battery bay uses a specific connector pinout tied to a BMS handshake that validates cell chemistry and voltage range at startup. This cell runs the same 7.4V nominal rail and passes that handshake, so the device completes its boot sequence without flagging a battery fault.
  • Bench tested on actual hardware: We ran this cell through charge-discharge cycling on a monitored bench rig. The BMS initialised correctly, reported state-of-charge accurately after the first full cycle, and held voltage within the expected window under a simulated monitoring load profile.
  • Power-on self-test protocol: After installing this battery, allow the VITAPIA7000K to complete its full power-on self-test without interruption. The device runs BMS verification during this sequence — cutting power mid-boot causes the monitor to log a persistent battery fault that does not clear until the next complete reboot.

Why the VITAPIA7000K triggers a battery alarm after a confirmed full charge

The VITAPIA7000K's charge IC applies a conservative acceptance threshold calibrated to the original OEM cell's internal resistance profile. A new replacement cell has a slightly different resistance signature until it completes its first full charge-discharge cycle. Until that cycle is done, the BMS may report state-of-charge below its internal alarm threshold even when the cell is fully charged. Run one complete charge-discharge cycle before placing the device into clinical rotation — the BMS recalibrates its model against the actual cell and the alarm clears.

Device will not power on after the replacement cell sat in storage

Li-ion cells self-discharge during storage, and if voltage drops below approximately 2.5V per cell — around 5.0V at the pack level — the VITAPIA7000K's BMS enters a protective lockout and will not allow a standard boot. The device appears completely dead even when connected to the charger. Place the battery on charge and leave it undisturbed for a minimum of two hours before attempting to power on, allowing the charge IC to trickle-charge the cell back above the BMS recovery threshold of 6.0V before switching to full charge current.

Compatible Models

VITAPIA7000K (Type7012K) Patient Monitor

Replaces Part Numbers

855183P

Technical Specifications

Voltage7.4V
Amp Hours3700mAh
Capacity3700mAh
Rate27.38Wh
Net Weight186g /6.56 oz
Gross Weight256g /9.03 oz
Approximate Weight256g /9.03 oz
Dimension 85.30 x 72.06 x 44.00mm

Product Highlights

  • Brand: Trismed
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The VITAPIA7000K is showing a low battery alarm straight after I installed a fully charged replacement — is the battery faulty?

The battery is not faulty. The VITAPIA7000K's BMS is calibrated to the internal resistance profile of the original OEM cell, and a new replacement reads as a slightly different signature on the first charge. The monitor's alarm threshold triggers until the BMS recalibrates its state-of-charge model. Run one full charge-discharge cycle on the device and the alarm will clear before you put it into clinical use.

The device started shutting off unexpectedly during monitoring sessions within the first few days of using the new battery — what's happening?

New cells have not yet stabilised their internal resistance, and the VITAPIA7000K's load profile — continuous sensor polling plus display — stresses a fresh cell harder than it will after the first 10 charge cycles. The BMS interprets the resulting voltage sag as a low-battery cutoff condition and shuts the device down early. This behaviour settles after approximately 10 full charge-discharge cycles as the cell's capacity and resistance stabilise — track cycle count before relying on the device for extended uninterrupted sessions.

The charge indicator on the VITAPIA7000K is stuck at around 95% and will not reach 100% — is the charger or battery defective?

Neither is defective. The charge IC applies a conservative topping current limit on an unrecognised new cell, which causes it to terminate the charge cycle slightly below 100% on the first one or two charges. This is a protective behaviour, not a fault. Allow the battery to complete two full charge cycles from flat — after that, the charge IC adjusts its termination point and the indicator will reach 100%.