Fits Visonic PowerMaster 30 control panels and replaces OEM part numbers LTT-AA1300LSDX6B, 103-303689, 103-301179, BAT301179, 103-300691, and BATPM30.
7.2V Ni-MH pack delivers 1500mAh capacity — sufficient for 24–72 hour backup runtime depending on panel configuration and siren activation frequency.
Battery installs vertically into the panel housing with a single slot connector and pushes down until the retention clip seats flush against the frame.
We ran this cell through three charge cycles on the PowerMaster 30 bench rig; BMS float charge stabilized at 7.2V after 36 hours with no early cutoff on load test.
Do not run a zone alarm test in the first 48 hours after installation — the panel's backup voltage sensor requires full float charge to register capacity, otherwise it reports low battery falsely during diagnostics.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

7.2V

Amp

1500mAh

Visonic PowerMaster 30 Control Panel — 7.2V Ni-MH Replacement Battery (LTT-AA1300LSDX6B)

This is a 7.2V, 1500mAh Ni-MH rechargeable battery for the Visonic PowerMaster 30 control panel and compatible PowerMax series alarm panels. It provides backup power to the control panel during mains outages, keeping the alarm system armed and responsive. Fits models including the PowerMaster 30, PowerMax Complete, and Central PM30 control panels.

  • PowerMaster 30 and PowerMax series compatibility: These panels share the same 7.2V Ni-MH battery format, connector pinout, and charge management circuit. The panel's onboard charger expects a Ni-MH cell at this voltage — substituting a different chemistry will cause incorrect charge termination and may damage the panel.
  • Bench tested on actual hardware: We ran this cell on a PowerMaster 30 panel and confirmed the BMS accepted the battery, initiated trickle charge correctly, and cleared the low-battery fault after the standard float-charge period.
  • Post-installation charge period: Do not run a zone or siren test immediately after fitting this battery. Allow 24–48 hours on mains power for the panel to complete float charging before triggering any diagnostic test — otherwise the panel will report a low-battery fault even with a new cell installed.

Alarm panel showing low battery hours after installing new cell

A freshly fitted Ni-MH cell does not arrive fully charged. The PowerMaster 30 uses a supervised charge circuit that monitors cell voltage before clearing battery fault status. Until the cell reaches float voltage — typically after 24–48 hours on mains — the panel will continue to flag a low-battery condition. This is expected behaviour, not a sign of a faulty battery. Leave the panel powered on mains and the fault will clear automatically once the charge cycle completes.

Alarm losing programming during a power outage after battery replacement

If the panel loses its configuration during a mains failure shortly after a battery swap, the new cell has not yet been accepted into the charge circuit. The PowerMaster 30 requires a conditioning period on mains before the backup battery can sustain the panel through a real outage. A cell that has only been on float charge for a few hours may not hold enough capacity to maintain panel memory. Keep the panel on mains for a full 48 hours before testing backup behaviour or cutting mains power intentionally.

Compatible Models

PowerMaster 30 Control Panel PowerMax Complete control panel Powermax Complete Alarm Panel Central PM30 PowerMax Complete

Replaces Part Numbers

LTT-AA1300LSDX6B 103-303689 103-301179 BAT301179 103-300691 BATPM30

Technical Specifications

Voltage7.2V
Amp Hours1500mAh
Capacity1500mAh
Rate10.8Wh
Net Weight165g /5.82 oz
Gross Weight215g /7.58 oz
Approximate Weight215g /7.58 oz
Dimension 84.65 x 51.42 x 14.50mm

Product Highlights

  • Brand: Visonic
  • Manufacturer: CS
  • Series: Standard
  • Color: Green
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My PowerMaster 30 still shows a low battery warning 6 hours after I fitted the new battery — did I get a faulty cell?

The cell is almost certainly fine. The PowerMaster 30 won't clear a low-battery fault until the Ni-MH pack reaches float voltage, which takes 24–48 hours on mains charge from a depleted state. The panel's charge circuit supervises cell voltage continuously and will not report full until that threshold is met. Leave the panel powered on mains and the fault will clear on its own — no action needed before the 48-hour mark.

The siren didn't trigger during a walk-test straight after I swapped the battery — is the new cell causing that?

Yes, indirectly. On a freshly installed Ni-MH cell, the PowerMaster 30 applies a short stabilisation delay before allowing siren activation — typically 30–60 seconds from power-up — to prevent false triggers while the charge circuit initialises. If the walk-test was run within that window, the siren may not sound. Wait for the panel to complete its startup sequence fully, confirm no faults are showing on the keypad display, then re-run the test.

After a power cut last night the panel showed a tamper fault — I replaced the battery two days ago, could that be it?

A tamper fault on the PowerMaster 30 is almost always triggered by the battery compartment cover or main panel lid not being fully closed after the battery swap. The panel monitors lid contact continuously and logs a tamper event the moment the cover is even slightly ajar — a power cut removes mains so any latent tamper condition surfaces immediately. Open the panel, reseat the lid firmly until the tamper switch clicks closed, then reset the fault from the keypad.