VOCA V530 Compatible Battery 3.7V 1000mAh Li-ion

Up to 20% off
New arrival
Sale priceFrom $27.99 USD Regular price $34.99
Shipping calculated at checkout.
Fits VOCA V530 smartphone, replaces original 3.7V lithium-ion cell SKU CS-AUM700SL.
3.7V nominal, 1000mAh capacity delivers standard runtime for compact smartphone daily use cycles.
Connector type and orientation match OEM slot without modification; locking tab seats flush against frame.
Bench testing showed BMS accepted charge cycle and voltage regulation held steady under screen load.
On first use after installation, disable fast charging for one complete discharge-charge cycle so the fuel gauge IC recalibrates against the new cell curve before high-current charging resumes.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3.7V

Amp

1000mAh

VOCA V530 — 3.7V Li-ion Replacement Battery

This is a 3.7V, 1000mAh Li-ion cell for the VOCA V530 smartphone. It replaces the original battery when the phone no longer holds charge through a standard day. Dimensions are 46.89 × 44.00 × 5.37mm — confirm these against your existing cell before ordering.

  • V530 form factor: The V530 uses a compact removable cell at this exact voltage and footprint. The connector pinout and cell dimensions must match — a cell even 0.5mm thicker can prevent the back cover from seating correctly.
  • Bench tested on actual hardware: We cycled this cell through charge and discharge on a smartphone test rig. The BMS accepted charge handshake correctly and held voltage above the modem-load threshold through full discharge without tripping overcurrent protection.
  • Fuel gauge recalibration on first use: On first use after installation, disable fast charging for one complete discharge-charge cycle. This lets the fuel gauge IC map the new cell's discharge curve before high-current charging pushes current into an uncalibrated cell — preventing erratic percentage readings from the first day.

Sudden shutdown at 20–30% on the V530 after a cell swap

This happens because the fuel gauge IC is still running the discharge curve from the old, degraded cell. When screen brightness or the modem spikes current draw, the new cell's voltage briefly dips below the shutdown threshold — even though the reported percentage looks safe. The OS sees a voltage cliff, not a capacity reading. Run one full discharge to 0% and a full charge to 100% without interruption; the coulomb counter resets and the shutdowns stop.

Phone warm near the battery compartment on the first charge cycle

A new cell starts with higher internal impedance than a broken-in one. The charge IC pushes current into that resistance, and the extra energy dissipates as heat in the first one or two cycles. Surface warmth — not hot to the touch — during the first full charge is normal and reduces as the cell breaks in. If the phone becomes too hot to hold, disconnect immediately and check that the replacement cell dimensions match the originals — a misfit cell sitting against other components traps heat.

Compatible Models

V530

Technical Specifications

Voltage3.7V
Amp Hours1000mAh
Capacity1000mAh
Rate3.7Wh
Net Weight22.1g /0.78 oz
Gross Weight47g /1.66 oz
Approximate Weight47g /1.66 oz
Dimension 46.89 x 44.00 x 5.37mm

Product Highlights

  • Brand: VOCA
  • Manufacturer: CS
  • Series: X-Longer
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My VOCA V530 keeps shutting off at around 25% battery — why does this happen with a new cell?

The fuel gauge IC calibrated itself to your old cell's discharge curve, which degraded over time. When the new cell hits a current spike — from the modem or screen — its voltage briefly drops below the shutdown threshold even though the reported percentage looks fine. Run one uninterrupted full discharge to 0% followed by a full charge to 100%. That forces the coulomb counter to remap against the new cell, and the premature shutdowns stop.

The V530 won't power on at all after the replacement battery sat in a drawer for a few months — is it dead?

Most likely the cell discharged below 2.5V in storage and the BMS locked out to prevent damage. Plug the phone into a wall charger — not a PC port — and leave it for 20–30 minutes without pressing the power button. The charge IC on most compact smartphones trickle-charges a locked-out cell back above 2.8V before the BMS re-initialises and allows normal boot. If the phone still shows nothing after 45 minutes on charge, check the charger output with a different device to rule out the cable.

The battery percentage on my V530 jumps around erratically — it reads 60%, then drops to 40% in seconds without any use.

This is the fuel gauge IC recalibrating against a cell it has no history with. The IC uses a stored discharge model from the old cell; the new cell's voltage-to-capacity curve does not match, so percentage estimates swing wildly under load. Complete two full discharge-charge cycles without interrupting them mid-way. After the second full cycle the IC has enough data points to track the new cell accurately, and the percentage stabilises.