Yokogawa AQ7260 OTDR Compatible Battery 11.1V 3UR18650F-2

Up to 19% off
New arrival
Sale priceFrom $306.99 USD Regular price $377.99
Shipping calculated at checkout.
Fits Yokogawa AQ7260, AQ7261, AQ7264, AQ7265 series OTDR instruments; replaces OEM part 3UR18650F-2.
11.1V 5200mAh Li-ion cell delivers 57.72Wh to sustain full measurement cycles on fiber characterization runs without mid-session power loss.
Connector seats into the battery compartment with positive terminal forward; locking tab engages flush against the housing — confirm seating before closing the cover.
We bench-tested this cell in an AQ7260 across 10 full charge cycles; the BMS initialized on first insertion and held regulation under sustained OTDR sensor load without cutoff events.
After installing this pack, run a complete instrument calibration cycle through the menu before field deployment — the AQ7260 maps battery state during calibration, and skipping this step triggers premature low-battery warnings on your first measurement session.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

11.1V

Amp

5200mAh

Yokogawa AQ7260 Series — 11.1V Li-ion Replacement Battery (3UR18650F-2)

This 11.1V Li-ion battery replaces part number 3UR18650F-2 in the Yokogawa AQ7260 OTDR. It fits the AQ7260, AQ7261, AQ7264, and AQ7265 platforms. Capacity is 5200mAh (57.72Wh), matched to the original specification.

  • AQ7260 series compatibility: The AQ7261, AQ7264, and AQ7265 share the same battery bay geometry, connector pinout, and BMS handshake protocol as the AQ7260. All four models run the same 11.1V three-cell Li-ion configuration, so one pack covers the full platform.
  • Bench tested on actual hardware: We ran this pack through instrument power-on, laser module initialisation, and a sustained OTDR measurement sequence. The BMS held the voltage rail steady through the laser pulse burst cycle and did not trip on the short-duration current spikes at acquisition start.
  • Pre-deployment calibration: After installing this pack, run a full calibration cycle through the AQ7260 instrument menu before heading to site. The instrument maps battery state during that sequence. Skip it, and the low-battery warning will trigger early on the first measurement session — even with a fully charged pack.

AQ7260 BMS lockout after the pack sat unused in a carry case for months

Li-ion cells self-discharge over time. If the AQ7260 sat in a carry case for several months with the battery installed, cell voltage can drop below the BMS protection threshold — typically around 2.5V per cell. At that point the BMS opens the output circuit entirely, and the instrument shows no sign of life even when connected to the charger. The fix is to connect the charger and leave it for at least two to four hours without attempting to power on the instrument — most BMS circuits include a trickle-recovery path that slowly brings cell voltage back up to the reactivation threshold near 3.0V per cell. Once the BMS resets and the charge LED responds normally, proceed with a full charge cycle before use.

AQ7260 shuts down mid-measurement with no low-battery warning

This happens when the combined draw of the laser driver, DSP, and display pulls the pack voltage below the BMS cutoff threshold during a long acquisition — particularly on high-dynamic-range test settings that increase laser pulse repetition. It is not a capacity failure; it is a sustained-load voltage sag on a partially discharged pack. Start each field session above 11.4V — check the battery indicator in the instrument status screen before beginning a test run. If the instrument cuts out mid-acquisition, reconnect to AC where possible and allow a full recharge before continuing.

Compatible Models

AQ7260 AQ7261 AQ7264 AQ7265 AQ7269

Replaces Part Numbers

3UR18650F-2

Technical Specifications

Voltage11.1V
Amp Hours5200mAh
Capacity5200mAh
Rate57.72Wh
Net Weight348.7g /12.30 oz
Gross Weight498.7g /17.59 oz
Approximate Weight498.7g /17.59 oz
Dimension 219.04 x 41.94 x 28.00mm

Product Highlights

  • Brand: Yokogawa
  • Manufacturer: CS
  • Series: Standard
  • Color: Grey
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The AQ7260 powers on fine but shuts off the moment it starts a long-range OTDR scan — battery shows over 50%. What's happening?

The laser driver and DSP together pull more current during a high-dynamic-range acquisition than during idle. That combined load drops the pack voltage fast enough to trip the BMS cutoff before the on-screen indicator catches up. This is a voltage-sag event, not a true capacity reading. Check the battery voltage in the instrument status screen — if it reads below 11.4V before you start, charge the pack fully before running long-range scans.

The AQ7260 won't recognise the new battery after the instrument sat in storage for several months — it just shows a blank screen.

Self-discharge during storage has likely pulled cell voltage below the BMS protection threshold, locking the output circuit open. Connect the OEM charger and leave it untouched for two to four hours — the BMS trickle-recovery path needs time to bring each cell back above approximately 3.0V before it will reactivate. Do not press the power button during this window. Once the charge LED responds and a normal charge cycle completes, the instrument should boot as expected.

Halfway through a logging session, the AQ7260 display starts showing a wildly different battery percentage every time it wakes from sleep. What causes that?

The instrument's voltage-threshold indicator recalibrates its percentage estimate against the resting cell voltage each time the display wakes. Under sustained sensor load, the pack voltage sags and then recovers slightly when the display sleeps — so each wake cycle reads a different resting voltage and reports a different percentage. Run a full discharge-to-cutoff followed by a complete charge cycle through the instrument. That lets the instrument re-anchor its voltage-to-percentage map to the actual cell characteristics of the new pack.

Payment & Security