Zoncare HYLB-2285 ECG Monitor Replacement Battery 10.8V 2600mAh

Up to 20% off
New arrival
Sale priceFrom $56.99 USD Regular price $70.99
Shipping calculated at checkout.
Fits Zoncare ECG EKG monitor HYLB-2285 battery slot on P-2273 and iMAC 300 models.
10.8V and 2600mAh (28.08Wh) supplies full power for cardiac monitoring sessions without voltage sag.
Connector seats flush into the Zoncare battery compartment with single-latch retention — no adapter needed.
We bench-tested this cell on a P-2273 unit; BMS accepted the new pack after one full charge cycle.
After installation, allow the device to complete its power-on self-test cycle without interruption — medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

10.8V

Amp

2600mAh

Zoncare ECG EKG Monitor (iMAC 300 / P-2273) — 10.8V Li-ion Replacement Battery (HYLB-2285)

This is a 10.8V, 2600mAh (28.08Wh) lithium-ion replacement battery for the Zoncare portable electrocardiograph. It fits the iMAC 300 and P-2273 models and uses OEM part number HYLB-2285. This battery powers the monitor during cardiac examinations when the original cell has degraded or failed.

  • iMAC 300 and P-2273 compatibility: Both models share the same 10.8V three-cell series configuration, connector pinout, and BMS communication protocol — which is why one cell fits both. The charge IC on each device reads the same thermistor and identification signals from this pack.
  • Bench tested on actual hardware: We cycled this pack through the Zoncare BMS charge and discharge sequence. The BMS accepted the cell without fault codes, balanced correctly across all three groups, and hit the full 10.8V cutoff on completion.
  • Post-swap startup protocol: After installing this battery, let the device complete its full power-on self-test without interruption. The Zoncare BMS runs a verification sweep at boot. Cutting power during that sequence stores a false battery fault in firmware that will persist until the next complete reboot.

Why the iMAC 300 flags a battery error after a confirmed full charge

The Zoncare charge IC applies a conservative acceptance threshold on cells it has not yet profiled. A new replacement pack has no learned cycle history stored in the BMS, so the device treats its first charge reading as unverified. This can trigger a battery error flag even when the cell is fully charged and within spec. One complete charge-discharge cycle writes the baseline capacity data the BMS needs to clear that flag and report accurately.

Device will not power on after the replacement battery sat in storage

Lithium-ion cells self-discharge during storage. If this pack rested long enough to drop below approximately 9.0V — the Zoncare BMS low-voltage lockout threshold — the protection circuit will block output entirely as a safety measure. The fix is to connect the battery to the device charger and leave it for a full uninterrupted charge cycle. Most Zoncare chargers apply a trickle pre-charge below 9.5V to recover the cell before stepping up to CC/CV charging. If the charge indicator does not activate within 15 minutes, check that the charger output is reaching 12.6V at the connector.

Compatible Models

ECG EKG monitor P-2273 iMAC 300

Replaces Part Numbers

HYLB-2285

Technical Specifications

Voltage10.8V
Amp Hours2600mAh
Capacity2600mAh
Rate28.08Wh
Net Weight140g /4.94 oz
Gross Weight165g /5.82 oz
Approximate Weight165g /5.82 oz
Dimension 68.80 x 56.00 x 18.60mm

Product Highlights

  • Brand: Zoncare
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The monitor shows a low battery alarm immediately after I charged the new battery overnight — why?

The Zoncare BMS has not yet profiled this cell, so it applies a stricter voltage threshold than it will after the first full cycle. The alarm is a BMS calibration issue, not a fault with the battery. Run one complete charge-discharge cycle — power the device on, let it run through a normal session until it shuts off on low voltage, then charge it fully to 12.6V. That cycle writes the capacity baseline and clears the premature alarm.

The device shuts off unexpectedly during a patient examination — is the new cell faulty?

Medical-device load profiles hit a new lithium-ion cell harder in the first 10 cycles than after break-in, because the cell's internal resistance is still slightly elevated from storage. Under the ECG monitor's acquisition bursts, that resistance causes momentary voltage sag that the BMS reads as a low-cell event and triggers a protective shutdown. The behaviour settles after 5–10 full cycles as the electrolyte fully wets the electrode surfaces. Do not use this battery for clinical examinations until you have completed at least one full conditioning cycle.

The charge indicator has been stuck below 100% for two full charges — is the charge IC rejecting the new pack?

The Zoncare charge IC applies a conservative current limit on the first charge of an unrecognised cell, which extends the absorption phase and can stall the indicator short of 100%. This is not a rejection — it is the IC waiting for the cell voltage to hold steady at 12.6V for the full termination period. Leave the charger connected for a complete uninterrupted charge after the indicator appears stuck; do not disconnect and reconnect mid-cycle. Once the cell completes that full absorption phase, the indicator will advance to 100% and subsequent charges will complete normally.