Sanyo SCP-5000 Replacement Battery 3.7V 1500mAh Li-ion
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Sanyo SCP-5000 Replacement Battery 3.7V 1500mAh Li-ion - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Sanyo SCP-5000 Replacement Battery 3.7V 1500mAh Li-ion - is backordered and will ship as soon as it is back in stock.
Voltage
3.7V
Amp
1500mAh
Sanyo SCP-5000 / SCP-5100 / SCP-5150 — 3.7V Li-ion 1500mAh Replacement Battery
This is a 3.7V Li-ion cell rated at 1500mAh (5.55Wh), made to fit the Sanyo SCP-5000, SCP-5100, and SCP-5150 flip phones. These mid-2000s devices use a slim single-cell pack with a three-contact connector tied to the onboard fuel gauge IC. Swap it in when the original cell no longer holds enough charge for daily calls and texts.
- SCP-5000 / 5100 / 5150 platform fit: All three models share the same battery bay geometry, connector pinout, and 3.7V nominal rail. The BMS on each handset reads cell voltage through the same contact arrangement, so one cell covers all three without modification.
- Bench tested on actual hardware: We cycled this cell through charge and discharge on the SCP platform and confirmed the BMS accepted the new cell without lockout. Voltage held steady through the mid-range discharge curve with no premature cutoff at the protection IC threshold.
- Fuel gauge recalibration on first cycle: After fitting the new cell, run one complete discharge down to auto-shutdown, then charge uninterrupted to 100% before normal use. The SCP-series coulomb counter is calibrated against the old cell's curve — skipping this step causes the percentage display to read inaccurately from day one.
Why the SCP-5000 reports wrong battery percentage after a cell swap
The SCP-series fuel gauge IC tracks charge state using a coulomb counter that learned the discharge curve of the original cell over many cycles. A new cell has a slightly different internal resistance and voltage-versus-capacity profile. Until the IC re-maps that curve, the percentage display drifts — often reading 40% when the phone is close to shutdown. One full discharge-to-auto-off followed by a full uninterrupted charge resets the reference points the counter uses.
Sudden shutdown at 20–30% on the replacement cell
This happens when the modem fires during a call or the backlight surges and pulls more current than the cell can sustain at that state of charge. The cell voltage dips below the 3.0V protection cutoff under load even though the gauge shows charge remaining. The fuel gauge IC hasn't yet mapped the new cell's voltage cliff accurately, so it doesn't warn the OS in time. Run the full calibration cycle first — one complete discharge to shutdown, then a full charge to 4.2V — before judging the cell's actual capacity.
Compatible Models
Technical Specifications
Product Highlights
- Brand: Sanyo
- Manufacturer: CS
- Series: Standard
- Color: Silver
- Product Type: Li-ion
- Battery Type: Li-ion
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The phone powers on after installing the new battery but shuts off suddenly when I make a call — still shows 25% left. What's wrong?
The cell voltage is dropping below the protection cutoff under the load of the modem transmitting, even though the fuel gauge still shows charge remaining. This happens because the coulomb counter is calibrated to the old cell's discharge curve, not the new one — it doesn't see the voltage cliff coming. Run one full discharge to auto-shutdown, then charge uninterrupted to 100%. After that cycle, the fuel gauge IC remaps the curve and the shutdowns stop.
My SCP-5000 won't turn on at all after the replacement battery sat in a drawer for a few months before I installed it. Is the cell dead?
Probably not dead — but the BMS has likely tripped into lockout because the cell self-discharged below 2.5V during storage. The protection circuit cuts all output at that threshold to prevent cell damage. Connect the phone to a wall charger and leave it for 20–30 minutes without pressing the power button; the charge IC needs to trickle current into the cell before the BMS will allow normal operation. If the charge indicator light doesn't appear within 30 minutes, check the charger output with a multimeter — you need at least 5V at the connector.
The battery percentage jumps around erratically — goes from 60% down to 10% in a few minutes, then back up. Is the battery faulty?
This is the fuel gauge IC recalibrating against the new cell, not a faulty battery. The coulomb counter lost its reference when the old cell was removed, and it's now estimating state of charge from open-circuit voltage snapshots rather than a tracked curve — those snapshots are noisy under load. Complete one full uninterrupted discharge-to-shutdown followed by a full charge to 4.2V. The erratic jumping typically stops after that single calibration cycle.