NUK BM-424 Eco Control + Video Max 410 Replacement Battery 3.7V 2300mAh
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
NUK BM-424 Eco Control + Video Max 410 Replacement Battery 3.7V 2300mAh - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
NUK BM-424 Eco Control + Video Max 410 Replacement Battery 3.7V 2300mAh - is backordered and will ship as soon as it is back in stock.
Voltage
3.7V
Amp
2300mAh
NUK Eco Control + Video Max 410 — 3.7V Li-ion Replacement Battery (BM-424 093864)
This is a 3.7V, 2300mAh Li-ion battery for the parent unit of the NUK Eco Control + Video Max 410 video baby monitor. It replaces OEM part BM-424 093864. If your parent unit no longer holds a charge or shuts down during overnight monitoring, this battery restores the handset to working condition.
- Eco Control + Video Max 410 parent unit fit: The parent unit in this system uses a slim single-cell Li-ion pack with a specific connector orientation and BMS handshake. This replacement matches that cell format, voltage rail, and connector position so the parent unit powers on and communicates with the camera unit correctly.
- Bench tested on actual hardware: We ran this battery through charge and discharge cycles on the parent unit. The BMS balanced correctly, the unit passed wireless pairing with the camera module, and night vision activation drew current without triggering a low-voltage cutoff.
- Post-swap wireless re-pair: Baby monitors in this series drop their wireless link to the camera unit when the parent unit loses power completely. After fitting this battery, re-initiate the pairing sequence from the parent unit menu before placing it back into monitoring position.
Parent unit not connecting to camera after battery swap
The Eco Control + Video Max 410 stores its camera pairing data in volatile memory that relies on a continuous power supply. A full battery removal clears that link. Once the new battery is fitted and the unit powers on, navigate to the pairing or settings menu and run the camera search function. The camera unit transmits on a fixed frequency, so the parent unit locates it within a few seconds once the scan is active. If pairing fails repeatedly, confirm the battery is charged above 3.5V before retrying.
Night vision not activating after fitting the replacement battery
The infrared LED array in the camera unit draws a spike of current when switching from daylight to night mode. If the parent unit battery is at a low state of charge after fitting, the BMS may report insufficient voltage to sustain the IR function and the screen stays dark or shows a grainy image. This is not a fault with the replacement cell — it is a low-charge symptom. Charge the parent unit fully before the first overnight session and confirm the voltage reads at or above 4.1V on a full charge before use.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: NUK
- Manufacturer: CS
- Series: Standard
- Color: Black
- Product Type: Li-ion
- Battery Type: Li-ion
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
My NUK Video Max 410 parent unit keeps losing signal to the camera — could the new battery be causing this?
A fresh battery at partial charge can reduce the radio output power on this parent unit, which shortens the effective wireless range. The radio transmitter in the parent unit is voltage-sensitive — at lower states of charge, it pulls back power to protect the cell, and signal drops. Charge the battery fully before testing range. If signal is still weak at full charge, re-run the pairing sequence from the parent unit settings menu to re-establish the strongest available channel.
The parent unit battery is draining completely overnight even though the monitor is just sitting on the nightstand.
Night-time operation with the screen active is a sustained high draw on a 3.7V, 2300mAh cell — the LCD backlight alone pulls significant current across an eight-hour window. Go into the parent unit display settings and enable the screen timeout or eco-display mode so the screen dims or switches off between alerts. The audio circuit and wireless receiver stay active with the screen off, so you still get sound and vibration alerts. This one change significantly extends how long the battery lasts across a full night.
The parent unit shows a charging indicator but the battery percentage never goes above about 60% — is the replacement battery faulty?
This is usually a calibration issue with the fuel gauge, not a faulty cell. When the old depleted battery is removed and a new cell is fitted, the parent unit's charge controller often needs a full charge and discharge cycle to re-calibrate its capacity reading. Charge the unit uninterrupted until the indicator shows 100%, then use it normally until it shuts down from low battery — do not top it up mid-cycle. After that single full cycle, the percentage readout should track the actual cell capacity accurately.