Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Van Lien 11190013V Emergency Light Replacement Battery 3.6V 4000mAh

Up to 20% off
New arrival
Sale priceFrom $46.99 USD Regular price $57.99
Shipping calculated at checkout.
Fits Van Lien 11190013V emergency lighting units; replaces OEM part 11190013V.
3.6V, 4000mAh Ni-CD chemistry delivers sustained output during mains failure without voltage sag.
Connector slides into the standard Van Lien fitting with positive terminal forward and locking tab seated.
We bench-tested the cell under continuous discharge load; BMS accepted the charge cycle without controller fault codes.
On first installation, run a full manual test cycle within 24 hours by holding the test button to rated duration — this confirms the new cell reaches capacity before your next scheduled compliance test.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3.6V

Amp

4000mAh

Van Lien 11190013V — 3.6V Ni-CD Replacement Battery (11190013V)

This is a 3.6V, 4000mAh Ni-CD cell for Van Lien emergency lighting units. It fits models 11190013V, 3SAVTD113LF, and SET A 3 ST D 4.0/HT LB. When the original cell can no longer hold charge, this replacement restores the fitting's ability to sustain illumination during a mains failure event.

  • Fits 11190013V, 3SAVTD113LF, and SET A 3 ST D 4.0/HT LB: These fittings share the same 3.6V charge rail, cell footprint, and trickle-charge acceptance window — which is why one cell covers all three variants without modification.
  • Bench tested on actual hardware: We ran this cell through a full charge cycle and a simulated mains-fail discharge. The BMS accepted the cell within its float voltage window and the fitting's charge indicator moved to green without manual intervention.
  • First test cycle after installation: Within 24 hours of fitting the new cell, hold the test button for the full rated duration. This lets the charge controller register the new cell's capacity and confirm load acceptance before your next compliance inspection — skipping this step is the most common reason a new battery fails its first duration test.

Charge indicator staying red after new battery installation

Ni-CD cells shipped in storage state typically sit at 3.0–3.2V — below the float acceptance threshold many Van Lien charge controllers expect on first contact. The controller reads that voltage as a fault condition rather than a dischargeable cell, so the indicator stays red. Leaving the fitting connected to mains for 12–24 hours allows the trickle circuit to bring the cell up past the acceptance threshold, usually around 3.6V nominal. If the indicator has not moved to green after 24 hours, disconnect and reconnect mains power to trigger a fresh controller poll.

Emergency light dims partway through a duration test after replacement

A freshly installed Ni-CD cell has not yet gone through a full charge-discharge conditioning cycle, so its usable capacity at the start is below the rated 4000mAh. Under sustained load during a duration test, voltage sags earlier than it will after conditioning. This is not a faulty cell — it is a cell that has not yet reached rated capacity. Run one complete manual test cycle immediately after installation: hold the test button until the light cuts out, then allow a full 24-hour recharge before the compliance test. Capacity reaches its rated level within the first two full cycles.

Compatible Models

11190013V 3SAVTD113LF SET A 3 ST D 4.0/HT LB

Replaces Part Numbers

11190013V

Technical Specifications

Voltage3.6V
Amp Hours4000mAh
Capacity4000mAh
Rate14.4Wh
Net Weight339.2g /11.96 oz
Gross Weight409.2g /14.43 oz
Approximate Weight409.2g /14.43 oz
Dimension 96.90 x 60.40 x 33.40mm

Product Highlights

  • Brand: Van Lien
  • Manufacturer: CS
  • Series: Standard
  • Color: White
  • Product Type: Ni-CD
  • Battery Type: Ni-CD
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My Van Lien emergency light passed installation fine but failed its three-hour duration test — is the new battery faulty?

Almost certainly not. A Ni-CD cell straight from storage has not completed a conditioning cycle, so its usable capacity on the first discharge is below the rated 4000mAh. Run one full manual test cycle — hold the test button until the lamp cuts out — then allow 24 hours on mains charge before repeating the duration test. Capacity normalises to rated output within the first two full cycles.

The fitting's fault LED is still on after I've confirmed the new cell is seated correctly — what's causing it?

Several Van Lien fittings latch the fault LED in hardware and do not clear it automatically when a new cell is detected. The charge controller needs a manual reset: disconnect the fitting from mains, wait 30 seconds, then reconnect. If the LED still does not clear after a full 24-hour charge, check that cell voltage has risen to at least 3.6V with a multimeter — a cell still below that threshold will keep the fault active.

The original battery in my Van Lien fitting looks swollen — what caused it and do I need to check anything before fitting the replacement?

Swelling in Ni-CD emergency lighting cells is caused by years of continuous trickle charge at elevated ambient temperature inside the fitting. Before installing the replacement, check the charge board for visible heat damage or discolouration around the charge resistor — a damaged charge circuit will overcharge the new cell in the same way. If the board looks clean, fit the new 3.6V cell, reconnect mains, and monitor the indicator over the first 24 hours to confirm the charge current is dropping to float level rather than staying at full charge rate.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.