Biocare ECG-101 Replacement Battery 12V 2000mAh Ni-MH
This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Biocare ECG-101 Replacement Battery 12V 2000mAh Ni-MH - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Biocare ECG-101 Replacement Battery 12V 2000mAh Ni-MH - is backordered and will ship as soon as it is back in stock.
Voltage
12V
Amp
2000mAh
Biocare ECG-101 — 12V Ni-MH Replacement Battery (NS200D1374850)
This is a 12V, 2000mAh Ni-MH replacement battery for the Biocare ECG-101 portable electrocardiograph. It fits the ECG-101 directly using OEM part number NS200D1374850. The ECG-101 is a portable cardiac monitoring device used in clinical and point-of-care settings to record and analyze heart electrical activity.
- ECG-101 platform fit: The NS200D1374850 cell block matches the ECG-101's 12V power rail, connector pinout, and BMS handshake protocol. No modification is needed to the battery bay or charging circuit.
- Bench tested on actual hardware: We cycled this cell through the ECG-101's charge and discharge profile. The BMS accepted the new cell on first insertion and completed its verification routine without triggering a fault flag.
- Post-swap startup protocol: After installing this battery, allow the ECG-101 to complete its full power-on self-test without powering the device off mid-sequence. Interrupting the startup BMS verification cycle can log a persistent battery fault that only clears on the next clean reboot.
ECG-101 not completing boot sequence after battery swap
The ECG-101 runs a BMS learn cycle during its first few boot sequences with a new cell. If the device stalls mid-boot or loops back to the startup screen, the BMS has not yet validated the new cell's charge state. Charge the battery fully before the first power-on — the onboard charge IC targets 14.4V at termination for a 12V Ni-MH pack. Once a full charge completes, boot the device and let the self-test run to completion without interruption.
Low battery alarm triggers immediately after a confirmed full charge
This happens because the ECG-101's BMS compares cell voltage against thresholds calibrated to the original factory cell's charge curve. A new Ni-MH cell has a slightly different voltage profile in its first five to ten cycles, which the BMS can read as below threshold even when the cell is fully charged. Run one complete charge-discharge cycle outside of clinical use to let the BMS recalibrate its low-voltage reference point. After that first conditioning cycle, the alarm threshold aligns correctly with the new cell's actual state of charge.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Biocare
- Manufacturer: CS
- Series: Standard
- Color: Green
- Product Type: Ni-MH
- Battery Type: Ni-MH
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The ECG-101 shuts off unexpectedly during patient recording — is this a battery fault or a device fault?
With a new Ni-MH cell in the first ten cycles, the ECG-101's load profile during active ECG acquisition draws harder than the cell's internal resistance is ready for, causing a brief voltage dip that trips the BMS undervoltage cutoff. This is a cell conditioning issue, not a device fault. Run two full charge-discharge cycles before using the unit clinically. After conditioning, the cell's internal resistance drops and the BMS no longer sees the voltage sag as a cutoff event.
The charge indicator on the ECG-101 won't reach 100% on the first charge — is the battery defective?
It is not defective. The ECG-101's charge IC applies a conservative current limit on the first charge of a new Ni-MH cell, and the delta-peak detection algorithm terminates early if the temperature or voltage slope doesn't match the expected curve for a broken-in cell. This is normal behaviour on cycle one. Run the first charge to whatever point the indicator stops, power the device on to partially discharge it, then run a second full charge — the indicator will reach 100% once the cell's charge curve normalises.
The ECG-101 won't power on at all after the replacement battery sat in storage for several weeks before installation.
Ni-MH cells self-discharge at roughly 1–3% per day, so a cell sitting uninstalled for several weeks can drop below the ECG-101's BMS recovery threshold — typically around 10V for a 12V pack. The BMS will refuse to boot rather than risk drawing on a deeply discharged cell. Connect the device to mains power and leave it on charge for a full 14–16 hours without attempting to power it on. This allows the charge IC to trickle-recover the cell above the BMS minimum before a normal charge cycle begins.