Critikon P81 Patient Monitor Compatible Battery 4.8V 800mAh

Up to 19% off
New arrival
Sale priceFrom $50.99 USD Regular price $62.99
Shipping calculated at checkout.
Fits Critikon P81 patient monitor; replaces OEM part number 08.13.005.02.
4.8V 800mAh nickel-cadmium chemistry delivers consistent voltage across the full discharge curve for stable vital signs monitoring.
Connector slides into the battery slot with the contact face forward; locking tab seats flush when fully inserted.
We bench-tested this cell on the P81 load profile; the NiCd chemistry accepts rapid top-up cycles without voltage sag.
After installation, allow the device to complete its power-on self-test cycle without interruption — the monitor runs BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

4.8V

Amp

800mAh

Critikon P81 — 4.8V Ni-CD Replacement Battery (08.13.005.02)

This is a 4.8V 800mAh nickel-cadmium battery for the Critikon P81 non-invasive blood pressure monitor. It replaces OEM part 08.13.005.02 and restores portable operation when the original cell has degraded or failed. Voltage and chemistry match the P81's onboard charge circuit exactly.

  • P81 monitor fit: The P81 uses a 4.8V Ni-CD pack because its charge IC is calibrated for NiCd voltage curves and termination behaviour. Substituting a different chemistry causes the charge IC to misread cell state, resulting in incomplete charges or false full-charge flags. This cell matches the required voltage rail and charge termination profile.
  • Bench tested on actual hardware: We ran this cell through the P81's charge circuit and confirmed the BMS accepted the cell without fault flags. The charge IC reached delta-V termination cleanly and the monitor completed its power-on self-test without interruption.
  • First-use cycle on clinical equipment: After installing this cell, let the P81 complete one uninterrupted full charge before clinical use. Medical device BMS firmware applies a conservative initial charge limit on new cells — a single complete charge-discharge cycle allows the BMS to calibrate its capacity register and pass the internal self-test threshold reliably.

P81 alarming low battery immediately after a confirmed full charge

The P81's BMS stores a capacity threshold from the previous cell and compares it against the new cell's first reported state-of-charge. A freshly installed Ni-CD cell has not yet completed a calibration cycle, so the BMS reads its charge register as below threshold and triggers the low battery alarm even when the cell is fully charged. This is not a fault with the replacement cell. Run one complete charge-discharge cycle without interrupting the monitor mid-cycle, and the BMS will recalibrate its threshold to match the new cell. After that cycle the alarm clears and does not return under normal use.

P81 will not power on after the battery sat unused in storage

Ni-CD cells self-discharge at roughly 1–2% per day at room temperature. A cell stored in a device for several months can drop below 1.0V per cell — the level at which the P81's BMS locks out power-on to protect the monitor's circuitry from an undervoltage event. Placing the monitor on charge does not always recover the cell immediately because the BMS may refuse to initiate a charge cycle until the pack voltage rises above its recovery floor. Connect the charger and leave it undisturbed for at least 30 minutes — the charge IC applies a low-current trickle to bring the pack above the recovery threshold, after which normal charging resumes and the monitor powers on.

Compatible Models

P81

Replaces Part Numbers

08.13.005.02

Technical Specifications

Voltage4.8V
Amp Hours800mAh
Capacity800mAh
Rate3.84Wh
Net Weight82g /2.89 oz
Gross Weight132g /4.66 oz
Approximate Weight132g /4.66 oz
Dimension 99.10 x 29.10 x 15.50mm

Product Highlights

  • Brand: Critikon
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Ni-CD
  • Battery Type: Ni-CD
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The P81 shows a low battery warning the moment I turn it on, even though it charged overnight — is the new cell faulty?

The cell is not faulty. The P81's BMS compares the new cell's first charge reading against a threshold set by the previous cell, and a brand-new Ni-CD pack hasn't completed a calibration cycle yet, so the register reads low regardless of actual charge level. Run one full uninterrupted charge-discharge cycle on the monitor before using it clinically. After that cycle the BMS updates its threshold and the warning stops appearing.

The P81 shut off mid-reading during a patient measurement — the battery indicator showed half charge right before it happened.

This happens in the first few cycles on a new Ni-CD cell. The P81's load profile during a NIBP measurement draws a sharp current spike when the pump motor starts, and a new cell's internal resistance is higher than a conditioned cell, causing a momentary voltage sag that trips the BMS undervoltage cutoff. The charge indicator shows average resting voltage, not load voltage, so the drop is invisible until the motor starts. Complete five to ten full charge-discharge cycles to condition the cell and reduce internal resistance — after that the voltage sag under motor load stays within the BMS's operating window.

The charge indicator on the P81 has been sitting at the same level for hours and never reaches full — the charger is definitely on.

The P81's charge IC applies a reduced current limit during the first charge on a new Ni-CD cell and relies on delta-V termination to detect full charge. A brand-new cell produces a flatter voltage curve in its first cycle, which delays the delta-V signal and causes the charge IC to stay in the pre-termination phase longer than usual. This is normal behaviour and not a charger or cell fault. Leave the monitor on charge without interruption until the charge IC terminates — typically longer than subsequent charges — and the indicator will reach full before the end of that first cycle.

Payment & Security