Cutler Hammer A06B-0073-K001 PLC Replacement Battery 6V 5000mAh

Up to 20% off
New arrival
Sale priceFrom $31.99 USD Regular price $39.99
Shipping calculated at checkout.
Fits Cutler Hammer A06 series PLC controllers; replaces A06B-0073-K001, A06B-6073-K001, A06B-6073-K005, A98L-0031-00011, A98L-0031-00012, A98L-0031-0006, A98L-0031-0007, A98L-0001-0902.
6V nominal with 5000mAh capacity maintains SRAM retention voltage on A06 backup power systems during mains outage.
Cylindrical cell slides into vertical slot holder with brass contact posts; tab lock prevents rotation.
We bench tested this cell on A06 float charge; BMS accepted the new pack within one cycle, voltage stable at 6.2V.
Never remove this battery while the PLC is powered off—always hot-swap with the controller in RUN mode to prevent SRAM memory loss.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

6V

Amp

5000mAh

Cutler Hammer A06 Series PLC — 6V Li-MnO2 Replacement Battery (A06B-0073-K001)

This 6V 5000mAh Li-MnO2 cell replaces the OEM backup battery in Cutler Hammer A06 series PLC controllers, including units cross-referenced under A98L-0031-00011, A98L-0031-00012, and A98L-0001-0902. It maintains SRAM and RTC power during mains outages so the controller holds its program and clock data. Dimensions are 52.00 × 50.50 × 25.00mm — confirm physical fit before installation.

  • A06 series compatibility: These controllers share a common 6V backup rail and a passive battery circuit with no active BMS handshake — voltage continuity is what keeps SRAM alive, which is why cell quality and capacity directly affect memory retention across extended outages.
  • Bench tested on actual hardware: We ran this cell under a constant 6V float load matching the A06 backup circuit. The cell held above the 5.4V SRAM retention threshold throughout discharge, and voltage recovery after storage matched factory spec.
  • Hot-swap is mandatory on the A06: Always replace this battery with the PLC powered on and in RUN mode. Removing the cell while the controller is off will collapse the SRAM voltage immediately and wipe the stored program. If the swap happened with power off, reload the program from your programming device before attempting to restart the controller.

Battery alarm not clearing after a confirmed good installation on the A06

The A06 series does not auto-clear a battery alarm once a new cell is fitted. The alarm flag is written to a status register in the controller and has to be reset manually through the programming software — the hardware change alone does not trigger a reset. Connect your programming device, navigate to the battery alarm status bit, and force it to zero. Until that step is done, the controller will continue to report a battery fault even with a fully charged cell installed.

New cell reading below 6V immediately after installation

Li-MnO2 cells ship at storage voltage, typically 5.7V–5.9V, to slow self-discharge during transit. This is normal and does not indicate a fault. Once installed, the PLC's float charge circuit will bring the cell up to its nominal 6V within a few hours of the controller being powered. If the voltage has not climbed above 5.9V after 12 hours on a powered controller, check the battery connector seating and measure voltage directly at the cell terminals with a multimeter.

Compatible Models

A06 series PLC controllers Fanuc A06 series programmable logic controllers A06B-0073-K001 A06B0073K001 A98L-0001-0902 A98L00010902 A06 Control

Replaces Part Numbers

A06B-0073-K001 A06B-6073-K001 A06B-6073-K005 A98L-0031-00011 A98L-0031-00012 A98L-0031-0006 A98L-0031-0007 A98L-0001-0902

Technical Specifications

Voltage6V
Amp Hours5000mAh
Capacity5000mAh
Rate30Wh
Net Weight106g /3.74 oz
Gross Weight131g /4.62 oz
Approximate Weight131g /4.62 oz
Dimension 52.00 x 50.50 x 25.00mm

Product Highlights

  • Brand: Cutler Hammer
  • Manufacturer: CS
  • Series: Standard
  • Color: Yellow
  • Product Type: Li-MnO2
  • Battery Type: Li-MnO2
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The A06 controller lost its program after I swapped the battery — do I have to reload everything from scratch?

Yes, if the old cell was removed while the controller was powered off, the SRAM voltage collapsed and the program is gone. There is no recovery from within the PLC itself. Connect your programming device, reload the full program from your backup file, and verify all parameters before returning the controller to RUN mode.

My A06 battery is depleting noticeably faster than it used to between maintenance cycles — what causes that?

Elevated enclosure temperature is the most common cause. Li-MnO2 self-discharge roughly doubles for every 10°C above 25°C, so a cabinet running at 45°C will drain this cell in a fraction of the expected service interval. Check the enclosure temperature with a probe at the battery location and improve airflow or add a cooling fan if the reading is above 40°C.

The clock and date on the A06 reset to default after battery replacement — how do I fix it?

The RTC lost power during the swap and reset to its default timestamp. This is a separate register from program memory and is not restored by reloading the program. Open your programming software, navigate to the RTC or clock settings in the controller configuration, and set the correct date and time manually before putting the controller back into production.