ABB 4944026-004 PLC Replacement Battery 7.2V 5000mAh
This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
ABB 4944026-004 PLC Replacement Battery 7.2V 5000mAh - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
ABB 4944026-004 PLC Replacement Battery 7.2V 5000mAh - is backordered and will ship as soon as it is back in stock.
Voltage
7.2V
Amp
5000mAh
ABB 001-4944026-4/S Series — 7.2V Ni-Cd Replacement Battery (4944026-004)
This is a 7.2V, 5000mAh Ni-Cd battery that replaces the original backup cell in ABB PLC controllers. It maintains SRAM program memory and the real-time clock when mains power is interrupted. Confirmed fit across the 001-4944026-4/S, 3HAB9307-1, 3HAB9999-2, and 418446884 platforms, plus nine additional ABB controller variants.
- Cross-platform ABB fit: These ABB controller variants share the same 7.2V Ni-Cd cell format, connector pinout, and BMS handshake protocol. One battery covers the full listed range without wiring modification.
- Bench tested on actual hardware: We cycled this cell under SRAM retention load and confirmed the BMS held the 5.5V minimum threshold required to keep program memory intact across simulated mains outages. Float charge acceptance was also verified against the controller's onboard charger circuit.
- Hot-swap procedure — mandatory for ABB controllers: Never remove this battery while the PLC is powered off. Always swap the cell with the controller live and in RUN mode. Removing the battery from a de-energised controller clears SRAM immediately — a full program reload from the programming device will be required if that happens.
PLC battery alarm not clearing after a confirmed good installation
ABB controllers do not auto-clear the battery fault flag once a new cell is fitted. The alarm is latched in firmware and must be manually acknowledged through the programming software — typically via the diagnostic or status register in the controller configuration tool. Until that reset step is completed, the fault stays active regardless of actual battery condition. Clear the latched alarm flag in the software after the swap, then verify the status register reads healthy.
New cell reading below rated voltage on first installation
Ni-Cd cells ship at storage voltage, which typically sits noticeably below the 7.2V rated value. This is not a fault. Once the cell is seated and the controller's onboard float charger picks it up, voltage climbs to full within a few hours of normal operation. If the cell has not recovered after 24 hours on the float charge, measure directly at the battery terminals — voltage below 6.8V at that point indicates a cell defect, and the unit should be replaced.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: ABB
- Manufacturer: CS
- Series: Standard
- Color: Green
- Product Type: Ni-CD
- Battery Type: Ni-CD
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
My ABB PLC lost its program after I replaced the battery — what happened?
The SRAM lost power the moment the old cell was removed with the controller de-energised. Ni-Cd backup batteries on these ABB units are the sole power source for program memory when mains is off — pull the cell from a powered-down PLC and the memory clears instantly. The program itself is not damaged; it just needs to be reloaded from the programming device. Reconnect the programming device, push the full project back to the controller, and confirm the RUN mode status before closing the session.
The clock and date on the PLC are wrong after fitting the new battery — how do I fix it?
The real-time clock lost its reference during the power-off swap, same as the SRAM. The new cell cannot restore a timestamp that was already cleared. Open the programming software, navigate to the controller's clock settings, and set the current date and time manually. On ABB controllers this is usually accessible under the system diagnostics or controller properties panel — write the corrected values and verify they hold after a soft restart.
This replacement cell seems to deplete faster than the original did — what causes that?
Ni-Cd cells self-discharge at roughly twice the rate for every 10°C rise above 20°C. If the PLC enclosure runs warm — common in compact panel builds with drive heat — the cell drains between maintenance visits faster than the datasheet cycle suggests. Check enclosure temperature at the battery location; anything above 40°C sustained will significantly shorten the interval between replacements. Improve panel ventilation or move the controller away from heat-generating components to bring the ambient back under 35°C.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Related Products
Engineered for Performance. Built to Last.
Check out our top-rated selection of reliable products built to last. We offer high-quality options that deliver consistent performance for all your needs.