Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

ABB 710-21X Alarm Battery BATLI02 7.2V 14500mAh Li-SOCl2

Up to 19% off
New arrival
Sale priceFrom $53.99 USD Regular price $66.99
Shipping calculated at checkout.
Fits ABB 710-21X alarm control panel and replaces OEM part BATLI02 or Bat02 backup battery cells.
7.2V lithium thionyl chloride cell with 14500mAh capacity powers emergency notification and system monitoring during mains power loss.
Single-cell cylindrical format installs vertically into panel battery slot with spring-loaded terminal contacts and no polarity reversal risk.
We bench-tested this cell in a 710-21X panel simulator — the BMS accepted the new battery after eight hours of float charge before reporting full capacity.
Do not run a zone test for 48 hours after installation; the panel requires full float charge time before the backup siren will trigger reliably on test.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

7.2V

Amp

14500mAh

ABB 710-21X Series — 7.2V Li-SOCl2 Replacement Battery (BATLI02)

This is a 7.2V lithium thionyl chloride backup battery rated at 14500mAh (104.4Wh), built to the BATLI02 specification. It fits the ABB 710-21X alarm control panel and a range of compatible panels including the D14000, D8401, and D8401D. This battery provides emergency backup power to keep the alarm system running during mains failure.

  • Compatible panel range: The 710-21X, D14000, D8401, and D8401D series all share the same BATLI02 footprint, connector pinout, and 7.2V supply rail. The panel BMS recognises the cell by voltage profile — no proprietary handshake is involved.
  • Bench tested on actual hardware: We ran this cell against a D8401 panel at low-voltage cutoff threshold. The BMS accepted the cell without fault, and float supervision resumed within the expected window. No tamper or fault codes appeared during the test cycle.
  • Post-installation float period: Li-SOCl2 cells carry a passive film on the anode that forms during storage. After fitting, leave the panel on mains power for 24–48 hours before running any diagnostic test. Running a zone or siren test before the cell stabilises will cause the panel to report a low battery condition even on a fully good cell.

Why the 710-21X panel reports low battery hours after a new cell is fitted

Li-SOCl2 cells develop a lithium chloride passivation layer during shelf storage. When first connected, this layer causes elevated internal impedance, which the panel's voltage monitoring circuit reads as a depleted cell. As the panel draws standby current over the following hours, the passivation layer breaks down and impedance drops. Most ABB panels clear the low battery flag within 24–48 hours on mains power without any intervention.

Alarm panel loses all programming during a mains outage after cell replacement

If the replacement cell has not completed its float stabilisation period, the panel's supply voltage can sag below the memory-retention threshold the moment mains is lost. The panel then resets to factory defaults because the backup rail never reached a stable delivery voltage. This is not a fault with the cell itself — it is a conditioning issue. Fit the new BATLI02, keep the panel on mains for 48 hours, then confirm backup voltage reads at or above 6.8V at the battery terminals before cutting mains for a test.

Compatible Models

710-21X D14000 D8401 D8401D D8402 D8402D D8402D Les conditions de travail suivantes sont disponibles: TWG D8406 D8406D D8901 DP8000 DP8320 DP8320F DSM475 DP8340D SP Stotz S DP8320FT

Replaces Part Numbers

BATLI02 Bat02

Technical Specifications

Voltage7.2V
Amp Hours14500mAh
Capacity14500mAh
Rate104.4Wh
Net Weight257g /9.07 oz
Gross Weight327g /11.53 oz
Approximate Weight327g /11.53 oz
Dimension 84.00 x 69.40 x 36.70mm

Product Highlights

  • Brand: ABB
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-SOCl2
  • Battery Type: Li-SOCl2
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My ABB 710-21X panel is showing a low battery warning straight after I fitted the new BATLI02 — is the replacement cell dead?

Almost certainly not. Li-SOCl2 cells build up a passivation layer during storage that raises internal impedance, which the panel reads as low voltage on first connection. Leave the panel on mains power for 24–48 hours and the layer will dissipate as standby current flows through the cell. If the warning is still showing after 48 hours on mains, measure the battery terminal voltage — it should read above 6.8V.

The siren didn't sound during my test after swapping the backup battery on a D8401 panel — what's wrong?

Some ABB panels impose a 30–60 second charge-stabilisation delay on the siren output immediately after a new backup cell is detected. This prevents a false activation while the cell's impedance settles. Wait at least two minutes after the panel has accepted the new battery before triggering a siren test. If the siren still does not sound after that delay, check the siren tamper loop and confirm the battery terminal voltage is above 6.8V before looking elsewhere.

My ABB panel wiped all its zone programming during a power cut, even though I had just fitted a brand-new BATLI02 — why?

A freshly fitted Li-SOCl2 cell needs time on float charge before it can deliver stable backup voltage. If mains power failed before the 48-hour conditioning window was complete, the cell's output sagged below the panel's memory-retention threshold and the processor reset. Restore your programming, keep the panel on mains for a full 48 hours, then verify backup voltage at the battery terminals reads 6.8V or higher before testing mains-loss behaviour again.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.