Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
BLU Star Jr Replacement Battery 3.7V 1450mAh C595005142L - is backordered and will ship as soon as it is back in stock.
Voltage
3.7V
Amp
1450mAh
BLU Star Jr / S350 — 3.7V Li-ion Replacement Battery (C595005142L)
This 3.7V, 1450mAh Li-ion cell replaces the original battery in the BLU Star Jr and S350 smartphones. It matches OEM part number C595005142L and fits the physical bay dimensions of both models. If your phone shuts down unexpectedly or no longer holds a charge, this is the direct cell swap.
- Star Jr and S350 compatibility: Both models run the same voltage rail and share an identical battery bay at 65.00 × 49.90 × 4.10mm with the same connector pinout and BMS handshake — one cell covers both.
- Bench tested on actual hardware: We cycled this cell through charge and discharge on the BLU S350 platform. The BMS accepted the charge handshake without fault codes, and the protection circuit triggered correctly at the low-voltage cutoff threshold.
- Fuel gauge recalibration after swap: After fitting this cell, disable fast charging and run one full discharge-charge cycle at standard rate. This lets the fuel gauge IC map the new cell's discharge curve before it starts reporting percentage to the OS — skipping this step causes erratic percentage jumps in the first few days.
Sudden shutdown at 20–30% on the BLU Star Jr after a cell swap
This happens because the fuel gauge IC is still using the discharge curve from the old, degraded cell. The new cell's actual voltage cliff sits at a different point, so the OS thinks 25% remains when the cell voltage has already dropped below what the modem and screen can sustain under load. The phone cuts power abruptly rather than tapering down. One full discharge-charge cycle at standard rate re-anchors the coulomb counter to the new cell curve and eliminates the premature cutoff.
Phone warm near the battery during the first few charges after replacement
A new high-impedance cell generates slightly more heat than a broken-in one during the initial charge cycles. The charge IC on the Star Jr pushes current at a fixed rate regardless of cell age, so internal resistance on a fresh cell produces more heat per cycle than you'd see later. This is normal for the first two or three charges and settles as internal resistance drops. If the phone stays warm after five full cycles, check that the replacement is seated flat — any gap between cell and back cover traps heat against the board.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: BLU
- Manufacturer: CS
- Series: X-Longer
- Color: Black
- Product Type: Li-ion
- Battery Type: Li-ion
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
My BLU Star Jr shuts off at around 25% battery — why does this keep happening with the new cell?
The fuel gauge IC calibrated itself to your old, worn cell's voltage curve and hasn't updated for the new one yet. When the new cell's voltage drops under modem or screen load, the IC still thinks there's charge left — until the phone hits the hardware cutoff and shuts down without warning. Run one complete discharge down to automatic power-off, then charge uninterrupted to 100% at standard rate. That single cycle re-anchors the coulomb counter and stops the early shutdown.
The BLU Star Jr won't power on at all after the replacement battery sat in a drawer for months — is the cell dead?
The BMS locks out the cell when voltage drops below approximately 2.5V per cell during extended storage — this is a protection trip, not a dead cell. Plug the phone into a wall charger and leave it for 20–30 minutes without pressing the power button. The charge IC trickle-charges the cell back above the BMS recovery threshold, at which point the phone will boot normally. If there's no response after 45 minutes on a known-good charger, check that the battery connector is fully seated.
The battery percentage on my BLU S350 jumps around erratically after fitting this replacement — is the battery faulty?
The percentage jumps are coming from the fuel gauge IC, not the cell itself. The IC holds a learned model of the old battery's charge curve, and the new cell's curve doesn't match — so the reported percentage lurches as the IC tries to reconcile real-time voltage readings against stale calibration data. This corrects itself after one or two full discharge-charge cycles at standard rate without interruption. Once the coulomb counter has tracked a complete cycle on the new cell, the percentage display stabilises.