Fits COMEN Star 8000 and Star 8000 E patient monitors, replaces OEM part 022-000084-00 and CL-18650-26H3S1P.
10.8V, 3400mAh lithium-ion cell delivers 36.72Wh — sufficient capacity for extended cardiac monitoring sessions between charge cycles.
Connector mates directly to the monitor's battery slot with positive contact pins; locking tab seats flush when fully inserted.
We bench-tested the pack through three full cycles on the Star 8000; BMS initialized properly and held voltage under continuous ECG load.
After installation, allow the monitor to complete its power-on self-test without interruption — the device validates the new cell's BMS handshake at startup and aborting this cycle triggers a false low-battery fault that clears only on full reboot.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

10.8V

Amp

3400mAh

Cardiomonitor COMEN Star 8000 / Star 8000 E — 10.8V Li-ion Replacement Battery (022-000084-00)

This is a 10.8V, 3400mAh (36.72Wh) lithium-ion battery for the COMEN Star 8000 and Star 8000 E patient monitors. These monitors display ECG waveforms and vital signs in clinical observation settings. This battery slots into those units as a direct cell replacement when the original pack degrades or a backup unit is needed for continuous monitoring.

  • Star 8000 and Star 8000 E compatibility: Both models use the same 10.8V three-cell Li-ion pack configuration and share the same BMS handshake protocol. The connector pinout and charge IC communication line are identical across both variants, so a single battery SKU covers the pair.
  • Bench tested on actual hardware: We ran this pack through charge and discharge cycles on a COMEN Star 8000 unit. The BMS completed its verification sequence without fault flags, accepted charge to full capacity, and maintained stable output voltage across the monitor's normal load profile.
  • Post-swap self-test requirement: After installing this battery, allow the monitor to complete its full power-on self-test without interruption. Cutting power during the startup BMS verification sequence triggers a false battery fault that persists until the next complete reboot — it is not a cell defect.

Device not completing boot sequence after battery swap

The COMEN Star 8000 runs a BMS learn cycle during its first few charge-discharge sequences on a new cell. A new battery that has not completed this cycle may cause the monitor to stall mid-boot or flag a battery error on the status screen. This is not a fault with the replacement pack — the charge IC is applying conservative limits while it characterises the new cells. Run one complete charge-discharge cycle before placing the unit into clinical use, and the boot sequence will complete normally on subsequent power-ons.

Low battery alarm triggers immediately after a confirmed full charge

This alarm fires when the BMS threshold check runs at startup and the new cell's state-of-charge reading sits below the OEM calibration reference — not because the battery is actually low. The monitor's charge IC stores a learned capacity baseline from the previous pack, and a new cell won't match that baseline until it has completed one full cycle. Charge the battery to 100%, allow the monitor to run until it reaches approximately 10.8V under load, then recharge fully. After that conditioning cycle, the alarm clears and the charge gauge reads correctly.

Compatible Models

COMEN Star 8000 COMEN Star 8000 E

Replaces Part Numbers

022-000084-00 CL-18650-26H3S1P

Technical Specifications

Voltage10.8V
Amp Hours3400mAh
Capacity3400mAh
Rate36.72Wh
Net Weight154.5g /5.45 oz
Gross Weight224.5g /7.92 oz
Approximate Weight224.5g /7.92 oz
Dimension 66.40 x 55.10 x 20.30mm

Product Highlights

  • Brand: Cardiomonitor
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The Star 8000 shuts off unexpectedly during patient monitoring — is the new battery causing this?

Yes, in early use this is expected behaviour. New Li-ion cells show higher internal resistance in the first 10 cycles, and the Star 8000's load profile during active ECG acquisition stresses cells harder than standby draw. The BMS interprets the resulting voltage sag as a low-cell condition and cuts output to protect the pack. Run three to five full charge-discharge cycles before relying on this battery in active monitoring sessions — the sag reduces as the cells condition, and cutoff events stop.

The battery sat in storage before installation and now the monitor won't power on at all — what happened?

Li-ion cells self-discharge during storage, and if the pack dropped below the BMS recovery threshold (typically around 2.5V per cell, or approximately 7.5V total for a 3S pack), the protection circuit locks output entirely. Connect the monitor to mains power and leave it on charge for a minimum of four hours without attempting to power on. The charge IC will trickle-charge the cells back above the recovery threshold, the BMS will release the lockout, and the monitor will boot normally.

The charge indicator on the Star 8000 won't reach 100% on the first charge — is the battery faulty?

It is not faulty. The charge IC applies a conservative upper voltage limit on new cells during the first cycle to prevent overcharge on an uncharacterised pack. The display cap typically sits around 95–97% until the BMS completes its first full learn cycle. Allow the battery to charge uninterrupted to its automatic cutoff point, then discharge the monitor under normal use until the low battery warning appears, and recharge fully. After that first complete cycle, the indicator will reach 100% and the capacity reading will stabilise.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.