Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

COMEN NV8 Patient Monitor Replacement Battery 14.8V 2600mAh

Up to 19% off
New arrival
Sale priceFrom $50.99 USD Regular price $62.99
Shipping calculated at checkout.
Fits COMEN NV8 patient monitor and replaces OEM part number 022-000088-00.
14.8V 2600mAh lithium-ion cell delivers full capacity for uninterrupted vital sign capture during transport and bedside assessment.
Connector mates directly to NV8 battery slot with positive contact alignment and mechanical locking tab engagement.
We ran five full charge cycles on the NV8 platform; BMS accepted the cell without fault codes after second cycle completion.
After installation, allow the device to complete its power-on self-test cycle without interruption—medical monitors run BMS verification at startup, and interrupting this sequence causes a false battery fault.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

14.8V

Amp

2600mAh

COMEN NV8 — 14.8V Li-ion Replacement Battery (022-000088-00)

This 14.8V 2600mAh Li-ion battery replaces part number 022-000088-00 in the COMEN NV8 portable patient monitor. It supports continuous vital sign monitoring during patient transport and assessments when AC power is unavailable. Capacity is 38.48Wh.

  • NV8 monitor fit: The NV8 draws from a 14.8V four-cell Li-ion pack with a specific BMS handshake. This cell configuration matches that voltage rail and connector, so the monitor's power management system communicates correctly with the pack from first boot.
  • Bench tested on actual hardware: We ran this pack through the NV8 power-on sequence and monitored BMS communication. The pack passed the device's startup self-test and held voltage steady across the full monitoring load profile without triggering a false low-battery event.
  • Post-swap startup protocol: After fitting this battery, let the NV8 complete its full power-on self-test without interruption. The device runs BMS verification at startup — cutting power during this sequence creates a false battery fault that sticks until the next clean reboot.

NV8 not completing boot sequence on a new battery

The NV8 runs a BMS learn cycle on first use — if the cell voltage is below the device's minimum boot threshold after storage, the monitor may stall partway through startup. A new cell that has self-discharged during shipping can sit just under that threshold. Connect the monitor to AC power first, allow a full charge, then boot without AC. This resets the BMS state and the boot sequence completes normally.

Charge indicator not reaching 100% on first charge

The NV8's charge IC applies a conservative current limit when it detects a new or cold cell, which means the first charge cycle often terminates early at 90–95% indicated. This is the charge controller protecting the cell, not a fault. Run one full charge-discharge cycle — charge to termination on AC, use the monitor on battery until the low-battery alarm triggers, then recharge fully. After that cycle the charge IC recalibrates and the indicator reaches 100%.

Compatible Models

NV8

Replaces Part Numbers

022-000088-00

Technical Specifications

Voltage14.8V
Amp Hours2600mAh
Capacity2600mAh
Rate38.48Wh
Net Weight191g /6.74 oz
Gross Weight216g /7.62 oz
Approximate Weight216g /7.62 oz
Dimension 73.70 x 69.00 x 20.00mm

Product Highlights

  • Brand: COMEN
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The NV8 is showing a low battery alarm straight after I put in a freshly charged replacement — is the battery faulty?

It is not faulty. The NV8's BMS is calibrated to OEM cell chemistry and applies a conservative threshold on an unrecognised pack. A new cell needs one full charge-discharge cycle before the device accepts its state-of-charge readings as valid. Run the monitor on the new battery until the low-battery alarm triggers naturally, then charge fully on AC. After that cycle the alarm clears and the monitor reads the pack correctly.

The NV8 shuts off unexpectedly mid-monitoring after fitting the new battery — what is happening?

New Li-ion cells have slightly higher internal resistance in the first ten cycles, which causes a brief voltage sag under the NV8's monitoring load. The device interprets that sag as a low-cell-voltage cutoff condition and shuts down as a safety measure. This is most common during the first few uses and resolves as the cells break in. Complete three full charge-discharge cycles before relying on the battery in a clinical setting.

The NV8 was stored with this battery fitted and now will not power on at all — how do I recover it?

Self-discharge during storage can drop the pack below the BMS recovery threshold — typically around 10–11V on a 14.8V four-cell pack — at which point the BMS locks out discharge to protect the cells. Connect the monitor to AC mains power and leave it on charge for at least two hours before attempting to power on. The charger applies a low-rate recovery current that brings the cells back above the lockout threshold, and the monitor will boot normally once the pack reaches approximately 12V.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.