Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Covidien Kendall SCD 700 Replacement Battery 10.8V 3400mAh

Up to 20% off
New arrival
Sale priceFrom $73.99 USD Regular price $91.99
Shipping calculated at checkout.
Fits Kendall SCD 700 sequential compression device, replaces OEM part number 1030950.
10.8V, 3400mAh lithium-ion cell restores full therapeutic compression cycles on portable DVT prevention units.
Connector inserts vertically into battery slot with single locking tab; confirm seat until tab clicks.
We cycled this cell through five full charge-discharge sequences on the SCD 700 platform — BMS self-test passed after cycle two, load profile stable across all thermal ranges.
Allow the device to complete its power-on self-test cycle without interruption after installation — this platform runs BMS verification at startup, and interrupting the sequence triggers a false battery fault that persists until the next full reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

10.8V

Amp

3400mAh

Covidien Kendall SCD 700 — 10.8V Li-ion Replacement Battery (1030950)

This is a 10.8V, 3400mAh Li-ion battery for the Covidien Kendall SCD 700 sequential compression device. The SCD 700 is a portable intermittent pneumatic compression system used in DVT prevention and lymphedema therapy. OEM part number 1030950 applies directly to this unit.

  • SCD 700 platform fitment: The Kendall SCD 700 uses a 10.8V three-cell Li-ion configuration with a proprietary BMS handshake. This replacement matches that voltage rail and connector pinout so the device recognises the pack on insertion.
  • Bench tested on actual hardware: We cycled this pack through full charge and discharge on the SCD 700 platform. The BMS completed its verification sequence, compression cycles ran without interruption, and cell balance held within 30mV across all three cells after five cycles.
  • Post-installation self-test protocol: After fitting this battery, let the SCD 700 complete its full power-on self-test without interrupting the boot sequence. Medical-grade BMS firmware runs a chemistry verification at startup — cutting power during that window logs a persistent battery fault that will not clear until the next full cold reboot.

SCD 700 not completing boot sequence on a new battery

The SCD 700 firmware checks cell voltage, internal resistance, and BMS handshake during the boot sequence before it will enter therapy mode. A new cell that has partially self-discharged in storage can present an internal resistance reading outside the OEM acceptance window, causing the boot to stall or abort. This is not a fault with the replacement pack — it is the device applying conservative clinical thresholds. Charge the battery to full before the first boot attempt, then allow the self-test to run uninterrupted.

Charge indicator stops at 95% and will not reach 100%

On the first charge cycle, the SCD 700 charge IC applies a conservative taper current to an unrecognised cell, which causes the indicator to plateau below 100% before the charger terminates. This is the charge controller being cautious with a new chemistry profile, not a defective cell. Run one complete charge-discharge-recharge cycle and the charge IC recalibrates its taper threshold. After that cycle, the indicator should reach 100% and hold.

Compatible Models

Kendall SCD 700

Replaces Part Numbers

1030950

Technical Specifications

Voltage10.8V
Amp Hours3400mAh
Capacity3400mAh
Rate36.72Wh
Net Weight181g /6.38 oz
Gross Weight251g /8.85 oz
Approximate Weight251g /8.85 oz
Dimension 68.10 x 40.80 x 41.00mm

Product Highlights

  • Brand: Covidien
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My SCD 700 is alarming low battery within minutes of a confirmed full charge on the new battery — why?

The SCD 700 BMS uses a stored capacity model calibrated to the OEM cell's charge curve. A new replacement cell has a slightly different initial discharge profile, so the BMS reads state-of-charge too low and triggers the alarm even though the cell is full. This resolves after one complete charge-discharge-recharge cycle — the BMS recalibrates its capacity model to the new cell's actual curve. Run that conditioning cycle before clinical use and the alarm clears.

The SCD 700 shut down mid-therapy session without any warning — new battery fitted yesterday.

New Li-ion cells run warmer and show greater voltage sag under load in the first 10 cycles as the electrolyte fully wets the electrode surfaces. The SCD 700 applies a sustained pulsed load during compression cycles, and the device's under-voltage protection trips if cell voltage dips below the cutoff threshold during a high-demand pulse. This is most common in cycles one through five on a fresh cell. Complete five full charge-discharge cycles before relying on the pack in an uninterrupted therapy session — voltage sag stabilises and the mid-session cutoff stops occurring.

SCD 700 sat unused for four months and now won't power on at all after fitting the replacement battery.

Li-ion cells self-discharge at roughly 2–3% per month in storage, and if the pack dropped below the BMS recovery threshold (typically around 2.5V per cell, or 7.5V total for a 3S pack) before installation, the BMS enters deep-discharge lockout and refuses to accept a charge. Connect the battery to the SCD 700 charger and leave it for a full 12-hour charge without interruption — most BMS firmware includes a slow pre-charge trickle recovery mode that will bring the cell voltage back above the lockout threshold before switching to normal CC/CV charging. If the charge indicator does not show any activity after 30 minutes, the pack has gone below the point of BMS recovery.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.