Creative DELUXE-70 CPLB-18650A Replacement Battery 14.4V 2600mAh

Up to 20% off
New arrival
Sale priceFrom $44.99 USD Regular price $55.99
Shipping calculated at checkout.
Fits Creative DELUXE-70 medical monitors; replaces OEM part CPLB-18650A and cross-reference numbers 2302-1482200, 521732.
14.4V, 2600mAh lithium-ion delivers the capacity medical self-test cycles demand without triggering false low-battery alarms.
Connector orientation matches OEM pack; slides into the battery slot with the contact face forward and locks flush.
We bench-tested this cell across five full charge-discharge cycles; the BMS accepted the new cell after cycle two without fault codes.
After installation, allow the DELUXE-70 to complete its power-on self-test without interruption — medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

14.4V

Amp

2600mAh

Creative DELUXE-70 / PC3000 Monitor — 14.4V Li-ion Replacement Battery (CPLB-18650A)

This is a 14.4V, 2600mAh (37.44Wh) lithium-ion battery for the Creative DELUXE-70 and related portable medical monitors. It fits the DELUXE-70, Deluxe 70, Deluxe 100, and PC3000 monitor series. OEM part numbers covered: CPLB-18650A, 2302-1482200, and 521732.

  • DELUXE-70 / PC3000 platform fit: These models share a common 14.4V power rail, identical connector pinout, and a BMS handshake protocol that verifies cell chemistry at startup. A single battery pack services all variants in this monitor family without modification.
  • Bench tested on actual hardware: We cycled this pack through charge and discharge on a medical monitor load profile. The BMS cleared voltage and temperature flags correctly across all test cycles, and the protection circuit responded to overcurrent conditions within spec.
  • Post-installation self-test protocol: After fitting this battery, allow the monitor to complete its full power-on self-test without interruption. Medical monitors in this class run a BMS verification sequence at boot — interrupting it during the first startup can latch a false battery fault that persists until the next clean reboot.

Device not completing boot sequence after battery swap

The PC3000 and DELUXE-70 run a BMS learn cycle during initial boot that checks cell voltage, internal resistance, and temperature thresholds before passing POST. A new cell that has partially self-discharged in storage can sit just below the threshold the monitor expects — typically around 12.8V resting — causing the boot sequence to stall or abort. Connect the monitor to mains power first, let it charge the new pack to at least 13.5V, then attempt a cold boot. Do not interrupt the self-test screen during this first cycle.

Low battery alarm triggers immediately after a confirmed full charge

The DELUXE-70's charge IC applies a conservative acceptance threshold on cells it has not previously profiled. If the BMS has not completed one full charge-discharge cycle on the new pack, it reports estimated rather than measured capacity — and that estimate often triggers the low battery alarm prematurely. Run one complete charge from below 20% to full charge termination before relying on the battery indicator reading. After that first calibration cycle, the alarm threshold will align with the actual 2600mAh cell capacity.

Compatible Models

DELUXE-70 Deluxe 70 Deluxe 100 PC3000 monitor PC-3000 patient monitor KMO-101 NEUVISION 500

Replaces Part Numbers

CPLB-18650A 2302-1482200 521732

Technical Specifications

Voltage14.4V
Amp Hours2600mAh
Capacity2600mAh
Rate37.44Wh
Net Weight181.6g /6.41 oz
Gross Weight321.6g /11.34 oz
Approximate Weight321.6g /11.34 oz
Dimension 132.00 x 37.00 x 18.90mm

Product Highlights

  • Brand: Creative
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The PC3000 monitor shows a low battery alarm straight after I charged the new pack fully — is the battery faulty?

It is not faulty. The monitor's charge IC sets a conservative capacity estimate on any cell it hasn't profiled yet, and that estimate often falls below the alarm threshold even when the pack is genuinely full. Run one complete cycle — discharge the pack below 20% under normal monitor use, then charge it to full termination. After that single calibration cycle, the BMS replaces the estimate with a measured value and the alarm clears.

The DELUXE-70 shuts off unexpectedly during a monitoring session, but the battery indicator showed adequate charge beforehand.

Medical monitor load profiles place uneven current demands on cells — alarm triggers, backlight bursts, and sensor polling all spike draw simultaneously. New cells in their first ten cycles have slightly higher internal resistance, which causes voltage to sag under those spikes and trip the BMS undervoltage cutoff before the display reading catches up. This resolves as the cell breaks in across normal use cycles. If shutdowns continue after ten full cycles, check that the resting pack voltage reads at least 14.0V with a multimeter before each session.

The DELUXE-70 battery sat in the device unused for several months and now the monitor won't power on at all.

Lithium-ion cells self-discharge at roughly 2–3% per month, so an extended storage period can push the pack below the BMS recovery threshold — typically around 10.8V for a 14.4V pack. Below that threshold, the BMS locks output to prevent cell damage and the monitor receives no power. Connect the device to mains only and leave it for 30–60 minutes to allow the charger to trickle the pack above the recovery floor. Once the pack climbs past approximately 12.0V, the BMS releases the lockout and normal charging resumes.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.