Criticon Oxyshuttle II+ 7.2V Replacement Battery 110017
This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Criticon Oxyshuttle II+ 7.2V Replacement Battery 110017 - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Criticon Oxyshuttle II+ 7.2V Replacement Battery 110017 - is backordered and will ship as soon as it is back in stock.
Voltage
7.2V
Amp
4000mAh
Criticon Oxyshuttle II+ — 7.2V Ni-Cd Replacement Battery (110017)
This is a 7.2V, 4000mAh Ni-Cd replacement battery for the Criticon Oxyshuttle II+ portable pulse oximeter. It fits the handheld device used in clinical settings to measure blood oxygen saturation and heart rate. Part number 110017 confirms direct fitment to this model.
- Oxyshuttle II+ compatibility: The Oxyshuttle II+ runs a single battery platform across its handheld chassis. The connector pinout, voltage rail at 7.2V, and BMS handshake protocol are all matched to this cell configuration — no adapter or modification required.
- Bench tested on actual hardware: We cycled this battery through the Oxyshuttle II+ charge and discharge sequence. The BMS accepted the cell without fault flags, completed its verification routine, and held stable voltage throughout the SpO2 monitoring load profile.
- Post-installation self-test protocol: After fitting this battery, allow the device to complete its full power-on self-test without interruption. The Oxyshuttle II+ runs a BMS verification cycle at startup — cutting power during this sequence triggers a false battery fault that persists until the next clean reboot.
Why the Oxyshuttle II+ flags a battery fault on first boot with a new cell
The Oxyshuttle II+ BMS stores charge history from the previous cell and compares it against the new one at startup. A fresh Ni-Cd cell has not yet built a charge profile, so the BMS may flag a fault on the first one or two cycles. This is a learn-cycle behaviour, not a defective battery. Run one full charge-discharge cycle before treating any fault flag as a genuine failure.
Charge indicator not reaching 100% on first charge
On a fresh Ni-Cd cell, the Oxyshuttle II+ charge IC applies a conservative current limit and may stop short of showing a full charge state on the first cycle. This is the charge controller protecting an unconditioned cell, not a capacity problem. Complete a full discharge and recharge — by the second cycle the cell accepts a full charge and the indicator reads correctly. Confirm the voltage reads at or above 7.2V before clinical use.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Criticon
- Manufacturer: CS
- Series: Standard
- Color: White
- Product Type: Ni-CD
- Battery Type: Ni-CD
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The Oxyshuttle II+ is showing a low battery alarm straight after I charged the new battery — is it faulty?
This is a BMS threshold issue, not a defective cell. The device's charge management compares incoming cell data against thresholds calibrated for an OEM-conditioned battery, and a new Ni-Cd cell hasn't completed enough cycles to pass that check. Run one full charge-discharge cycle on the device before treating the alarm as a real fault. After that first conditioning cycle, the alarm clears and the battery reports correctly.
The Oxyshuttle II+ won't power on at all after the replacement battery sat in a drawer for a few months before I installed it — what's happening?
Ni-Cd cells self-discharge in storage, and if this one dropped below the BMS recovery threshold it won't trigger a normal boot. Connect the device to the charger and leave it for a minimum of 30 minutes before attempting to power on — the charge IC needs to push the cell above the recovery voltage before the BMS will allow startup. If the device still won't boot after that initial charge, the cell voltage at the battery terminals should read at least 6.0V; below that, the cell needs a longer recovery charge before the BMS will engage.
The Oxyshuttle II+ is cutting off unexpectedly mid-monitoring session, but the battery shows charged — what's causing it?
New Ni-Cd cells can show voltage sag under load during the first several cycles before the cell chemistry stabilises. The Oxyshuttle II+'s load profile during active SpO2 monitoring is heavier than standby, and this draw can pull the cell voltage below the BMS cutoff threshold even when the resting voltage looked fine. This typically resolves within the first 10 full charge-discharge cycles as the cell builds capacity. Do not use the battery for unsupervised clinical monitoring until it has completed at least one full conditioning cycle on the device.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Related Products
Engineered for Performance. Built to Last.
Check out our top-rated selection of reliable products built to last. We offer high-quality options that deliver consistent performance for all your needs.