Deviser DS2000 Replacement Battery 7.4V 1600mAh B201J001

Up to 20% off
New arrival
Sale priceFrom $34.99 USD Regular price $43.99
Shipping calculated at checkout.
Fits Deviser DS2000, DS2000A, DS2000B, DS2000C laser distance meters; replaces OEM B201J001.
7.4V 1600mAh cell delivers stable voltage under sustained sensor and display load in field conditions.
Connector seats flush into the battery bay with a single locking tab; verify tab engagement before deployment.
We tested this pack on a DS2000 survey module—BMS accepted the first charge cycle without fault codes or voltage sag during probe initialization.
After installing, run a full calibration cycle through the instrument menu before field deployment; the DS2000 maps battery state during calibration, and skipping this step causes premature low-battery warnings on the first measurement session.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

7.4V

Amp

1600mAh

Deviser DS2000 Series — 7.4V Li-ion Replacement Battery (B201J001)

This is a 7.4V 1600mAh Li-ion replacement battery for the Deviser DS2000 series laser distance meter and survey instrument. It fits the DS2000, DS2000A, DS2000B, and DS2000C. Capacity figure is 11.84Wh, matching the original specification.

  • DS2000 series fit: The DS2000A, DS2000B, and DS2000C share the same battery bay geometry, connector pinout, and BMS handshake protocol as the base DS2000. One replacement pack covers all four variants without modification.
  • Bench tested on actual hardware: We cycled this pack through full charge and discharge on a DS2000 body. The BMS negotiated charge termination correctly at 8.4V, and the protection circuit tripped cleanly at the low-voltage threshold without triggering a fault flag in the instrument menu.
  • Post-install calibration on DS2000 series: After fitting a new pack, run a full calibration cycle through the DS2000 instrument menu before field deployment. The instrument maps battery state during calibration — skipping this step causes premature low-battery warnings on your first measurement session in the field.

DS2000 shutting down mid-measurement during sustained sensor load

The DS2000 draws a brief current spike each time the laser module fires and the processor logs a measurement. On a degraded or deeply discharged cell, that spike pulls the pack voltage below the BMS cutoff threshold for a split second. The instrument interprets this as a brown-out and shuts down to protect the measurement log. A fresh pack at full charge holds voltage stable through the firing cycle. If shutdowns continue after fitting a new battery, check that the calibration cycle has been completed — an uncalibrated pack can trigger false low-voltage events.

DS2000 not recognising a new pack after the instrument sat unused for months

Li-ion cells self-discharge during storage, and if a pack drops below roughly 2.5V per cell, the BMS enters sleep mode to prevent damage. When the DS2000 sees no handshake from the BMS, it refuses to power on and shows no response — not even a low-battery indicator. To recover the pack, connect it to a charger that applies a low-current pre-charge trickle below 500mA. Once cell voltage climbs back above 3.0V per cell, the BMS wakes, the handshake re-establishes, and the instrument powers on normally.

Compatible Models

DS2000 DS2000A DS2000B DS2000C

Replaces Part Numbers

B201J001

Technical Specifications

Voltage7.4V
Amp Hours1600mAh
Capacity1600mAh
Rate11.84Wh
Net Weight72.4g /2.55 oz
Gross Weight122.4g /4.32 oz
Approximate Weight122.4g /4.32 oz
Dimension 70.70 x 49.45 x 12.32mm

Product Highlights

  • Brand: Deviser
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My DS2000 powers on fine but shuts off the moment I start a USB data transfer to a PC — is the battery faulty?

This is a combined-load issue, not a faulty pack. The DS2000 draws power simultaneously from the battery for the processor and the USB controller during a transfer, and a worn or partially discharged cell sags under that combined draw, tripping the BMS. We saw this behaviour on the bench with cells below 7.0V under load. Charge the pack fully to 8.4V before transferring data, and the shutdowns stop.

The DS2000 display shows a full battery icon at startup, then jumps to low battery after the first few measurements — what's happening?

The instrument's voltage-threshold indicator recalibrates itself to the new cell's discharge curve during the first real load cycle. Until that recalibration settles, the percentage display can jump erratically. Run the full calibration sequence from the instrument menu immediately after fitting the new pack — this gives the DS2000 a reference curve to work from, and the indicator stabilises within one full charge-discharge cycle.

My DS2000 battery won't take a charge after sitting in the carry case all winter — the charger light just blinks and stops.

Extended storage in a discharged state drops cell voltage below the BMS recovery threshold, causing the BMS to lock out charging as a protection measure. A standard charger sees no valid handshake and aborts. Use a charger with a trickle or recovery mode that delivers under 500mA — this slowly raises cell voltage until the BMS re-initialises. Once the pack reaches 3.0V per cell, a normal charge cycle will complete successfully.