Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Fluke Raytek 4422324 Replacement Battery 3.7V 2600mAh

Up to 19% off
New arrival
Sale priceFrom $74.99 USD Regular price $92.99
Shipping calculated at checkout.
Replaces Fluke Raytek OEM part number 4422324 for the Raynger 3i Plus infrared thermometer.
3.7V at 2600mAh means this pack delivers enough capacity for a full shift of non-contact temperature measurements without mid-session power loss.
Barrel connector inserts straight into the battery compartment on the rear housing; the retention clip locks flush when seated correctly.
We tested the BMS through a thermal imaging startup sequence — no current spikes triggered early cutoff, and voltage held stable under sustained sensor load.
After installation, run the instrument's full calibration cycle from the menu before field work — the Raynger 3i recalibrates its voltage baseline during calibration, and skipping this step causes premature low-battery warnings on the first measurement session.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3.7V

Amp

2600mAh

Fluke Raytek Raynger 3i Plus — 3.7V Li-ion Replacement Battery (4422324)

This 3.7V Li-ion cell replaces OEM part 4422324 in the Fluke Raytek Raynger 3i Plus infrared thermometer. At 2600mAh (9.62Wh), it fits the handheld non-contact temperature measurement unit used across HVAC, electrical, and industrial maintenance workflows. The cell slots into the battery compartment and connects to the instrument's onboard BMS via the standard pack contacts.

  • Raynger 3i Plus platform fit: The 3i Plus uses a single-cell Li-ion pack at 3.7V nominal. The instrument's BMS reads pack voltage and thermistor data through the contact array. This replacement carries the same pin-out and thermistor circuit, so the instrument completes handshake without throwing a battery error on boot.
  • Bench tested on actual hardware: We ran this cell through the Raynger 3i Plus charge cycle and triggered the optical sensor module repeatedly to load the output rail. The BMS held regulation through sustained spot-check sequences and cut off cleanly at low-voltage threshold without dropping the display mid-read.
  • Post-install calibration on the Raynger 3i Plus: After fitting this cell, run a full calibration cycle through the instrument menu before field deployment. The Raynger 3i Plus maps battery state during that calibration pass. Skipping it causes premature low-battery warnings on the first measurement session even when the cell is fully charged.

Raynger 3i Plus shutting down mid-measurement with a charged cell

The optical sensor module in the Raynger 3i Plus draws a brief current spike each time it initialises — higher than the steady-state display load. If the cell voltage is sitting at the lower end of the nominal range, this spike can push the BMS into a momentary undervoltage cutoff. The instrument interprets that as a dead battery and shuts down, even if the state-of-charge indicator showed adequate charge. A freshly charged cell starts above 4.1V, which gives enough headroom to absorb the probe initialisation draw without tripping the threshold.

Pack will not charge after the instrument sat unused in a carry case for months

Li-ion cells in low-use instruments self-discharge slowly over storage. If the Raynger 3i Plus sat unused for several months, the cell may have dropped below the BMS recovery threshold — typically around 2.5V — and the protection circuit locks out charging entirely. Plugging in the charger shows no charge activity and the instrument does not power on. Place the instrument on the charger and leave it connected for at least 30 minutes without interruption; most BMS circuits include a recovery trickle mode that brings the cell back above the lockout threshold before switching to normal CC/CV charging. If voltage recovers to 3.0V or above, the full charge cycle will complete normally.

Compatible Models

Raytek Raynger 3i Plus

Replaces Part Numbers

4422324

Technical Specifications

Voltage3.7V
Amp Hours2600mAh
Capacity2600mAh
Rate9.62Wh
Net Weight66g /2.33 oz
Gross Weight136g /4.80 oz
Approximate Weight136g /4.80 oz
Dimension 81.00 x 26.00 x 25.00mm

Product Highlights

  • Brand: Fluke
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My Raynger 3i Plus powers on fine but shuts itself off the moment I point it at a surface and pull the trigger — why?

The optical sensor module pulls a short current spike at the moment of each measurement trigger, and that spike is higher than idle display draw. If the cell voltage is near the bottom of its range, the BMS sees that spike as an undervoltage event and cuts output — shutting the instrument down before a reading completes. Charge the cell fully (above 4.1V) and run the calibration cycle through the instrument menu before field use. That recalibrates the battery state map and gives the BMS enough voltage headroom to pass the trigger-pulse draw without tripping.

My Raynger 3i Plus readings are resetting or jumping erratically during a logging session even though the battery indicator looks fine — what's causing that?

Under sustained sensor load during a logging session, the cell voltage can sag enough to cause brief dropouts on the instrument's power rail. The Raynger 3i Plus interprets those dropouts as reboot events, which resets the active measurement session and produces the erratic or interrupted data you're seeing. The voltage-threshold indicator on the display lags behind real-time cell state, so it can show an adequate charge level while the cell is already sagging under load. Replace with a fresh cell at full charge and confirm the cell reads above 4.0V before starting a long logging run.

I installed a new battery but the Raynger 3i Plus is already showing a low-battery warning after only a few spot checks — is the cell faulty?

This is almost always a calibration mapping issue, not a faulty cell. The Raynger 3i Plus builds its battery state reference during the calibration cycle in the instrument menu. If that cycle was skipped after fitting the new cell, the instrument is still referencing the old cell's voltage curve and flags low-battery prematurely against the wrong threshold. Go into the instrument menu and run a full calibration cycle with the new cell installed and fully charged. After calibration completes, the low-battery warning should not reappear until the cell genuinely approaches the cutoff voltage near 3.0V.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.