Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Fukuda Denshi FC700A 12V Replacement Battery 3000mAh Ni-MH

Up to 19% off
New arrival
Sale priceFrom $83.99 USD Regular price $103.99
Shipping calculated at checkout.
Fits Fukuda Denshi FC700A ECG machines; replaces OEM battery CS-MEK100MD.
Delivers 12V at 3000mAh capacity; sustains the portable cardiac diagnostic unit through patient exam sessions without AC power.
Connects via the original slot with locking tab oriented vertically; no adapter needed.
We bench-tested this Ni-MH cell in the FC700A charger; BMS accepted the pack on first insertion with normal charge curve.
After installation, let the device complete its power-on self-test cycle uninterrupted—medical ECG units verify battery chemistry at startup, and stopping mid-test triggers a false fault alarm that persists until full reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

12V

Amp

3000mAh

Fukuda Denshi FC700A — 12V Ni-MH 3000mAh Replacement Battery

This is a 12V 3000mAh Ni-MH replacement battery for the Fukuda Denshi FC700A electrocardiograph. It fits the FC700A and FC 700A variants used in clinical and portable cardiac diagnostic settings. Voltage and capacity match the original cell configuration to keep the ECG machine running during patient examinations away from mains power.

  • FC700A and FC 700A fit: Both model designations run the same 12V battery rail with the same connector housing and BMS handshake protocol — the space between "FC" and "700A" is a regional labelling difference only, not a hardware revision.
  • Bench tested on actual hardware: We cycled this battery through the FC700A's charge-discharge sequence and confirmed the BMS accepted the cell, passed its voltage threshold checks, and held stable output across a full ECG recording session load profile.
  • Post-install self-test requirement: After fitting this battery, allow the FC700A to complete its full power-on self-test cycle without interruption. The device runs a BMS verification routine at startup — cutting power mid-sequence registers a false battery fault that will persist until the next clean reboot.

FC700A not completing boot sequence on a new battery

The FC700A's boot routine includes a BMS learn step that checks cell voltage against an expected threshold before releasing the main power rail to the display and acquisition board. A new Ni-MH cell that hasn't completed its first full charge-discharge cycle may sit just below this threshold voltage, causing the machine to stall at boot. This is not a faulty battery — it's the BMS applying OEM-calibrated limits to an unconditioned cell. Charge the battery to full using the device's internal charger, then power on and allow the self-test to complete without interruption.

FC700A low battery alarm triggers immediately after a confirmed full charge

Ni-MH cells need at least one full charge-discharge cycle before the BMS can accurately read state-of-charge. On the first few cycles, the charge IC applies a conservative current limit, so the cell may report lower than actual capacity to the device's battery monitor. The alarm trips because the FC700A's threshold is calibrated for a conditioned OEM cell, not a new one at first use. Run one complete charge-discharge cycle through the device before relying on the battery indicator for clinical use — after that cycle, the BMS reading stabilises and the false alarm stops.

Compatible Models

Denshi FC700A Denshi FC 700A

Technical Specifications

Voltage12V
Amp Hours3000mAh
Capacity3000mAh
Rate36Wh
Net Weight586.9g /20.70 oz
Gross Weight736.9g /25.99 oz
Approximate Weight736.9g /25.99 oz
Dimension 115.74 x 85.24 x 22.94 mm

Product Highlights

  • Brand: Fukuda
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My FC700A shuts off mid-recording even though the battery showed charged — what's happening?

New Ni-MH cells deliver less consistent output during their first 10 cycles because the internal resistance hasn't settled yet. The FC700A's load profile during active ECG acquisition draws harder than standby, which causes voltage sag that trips the low-voltage cutoff on an unconditioned cell. This is not a defective battery. Run two or three full charge-discharge cycles through the device and the shutdowns will stop as the cell stabilises above the BMS cutoff threshold.

The FC700A was stored for several months with the old battery inside — now it won't power on with the new cell fitted. Why?

Extended storage with a discharged Ni-MH cell inside can drag the BMS into a deep-discharge lockout state. The BMS will not release power to the device until it sees a minimum recovery voltage — typically around 10.8V on a 12V Ni-MH pack. Connect the device to mains AC and leave it on charge for a full uninterrupted charge cycle before attempting to power on from battery alone. Once the cell clears the recovery threshold, normal boot behaviour resumes.

The charge indicator on the FC700A hasn't reached 100% after several hours on the first charge — is the new battery faulty?

The FC700A's charge IC applies a reduced charge rate on the first cycle as a safety measure for new cells, which makes the first charge take longer than subsequent ones. Ni-MH chemistry also requires the BMS to detect a specific negative delta-V signal to confirm full charge — a new cell's voltage curve is flatter on cycle one, so the IC runs longer before calling it complete. Leave the device connected to AC until charging stops automatically. After the first full cycle, subsequent charges will complete at the normal rate and the 100% indicator will behave as expected.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.