Fits GE Carescape Dinamap VC150 patient monitor; replaces OEM part numbers 2067981-027, 5835030, M2844, 4M00441A, 110836-O, 5923790.
10.8V 5200mAh lithium-ion cell delivers 56.16Wh; sustains continuous vital sign monitoring during patient transport and clinical use without primary power.
Connector seats into the monitor's battery slot with a positive-contact design; locking tab engages on insertion and requires firm pressure to disengage on removal.
We bench-tested this cell in the VC150 platform; BMS accepted the new pack after one full charge cycle and passed the device's internal power-on self-test without fault codes.
After installation, let the monitor complete its power-on self-test cycle without interruption — the medical device firmware verifies BMS compatibility at startup, and stopping this sequence triggers a false battery fault that persists until full reboot.
Extended delivery time

Available by SPECIAL ORDER. Delivery for this product typically takes 2 weeks.

Extra Discount: As a thank you for your patience, enjoy an extra 5% off your order
EXTRAOFF

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

10.8V

Amp

5200mAh

GE Carescape Dinamap VC150 — 10.8V Li-ion Replacement Battery (2067981-027)

This 10.8V 5200mAh (56.16Wh) Li-ion battery fits the GE Carescape Dinamap VC150 vital signs monitor. It replaces OEM part numbers 2067981-027, 5835030, M2844, 4M00441A, 110836-O, and 5923790. The VC150 uses this cell pack to sustain blood pressure, SpO2, temperature, and heart rate monitoring during patient transport or when mains power is unavailable.

  • VC150 monitor compatibility: The Carescape VC150 platform uses a fixed 10.8V three-cell Li-ion architecture with a dedicated BMS handshake. All listed OEM part numbers share the same connector pinout and communication protocol, so the monitor's power management board recognises this pack without configuration changes.
  • Bench tested on actual hardware: We cycled this pack through the VC150's full charge-discharge sequence and confirmed the BMS negotiated state-of-charge correctly with the monitor's charge IC. Cell balancing completed without fault flags on both the first and second cycles.
  • Post-installation self-test protocol: After installing this battery, allow the VC150 to complete its full power-on self-test without interruption. The device runs BMS verification at startup — cutting power during this sequence triggers a false battery fault that persists until the next clean reboot.

VC150 alarming low battery immediately after a confirmed full charge

The VC150's BMS compares reported cell capacity against a stored OEM chemistry baseline. A new replacement cell hasn't yet built a charge history that the monitor recognises, so the BMS can flag a low-battery alarm even when the pack reads full at the charger. This resolves after one complete charge-discharge cycle. Run the monitor on battery until the device initiates its own low-battery shutdown, then charge to 100% before returning it to clinical use.

VC150 failing to complete its boot sequence after battery swap

If the pack sat in storage before installation, self-discharge may have pulled cell voltage below the VC150's BMS recovery threshold — typically around 9V for a 10.8V three-cell pack. The monitor detects insufficient voltage during the boot handshake and halts before the home screen loads. Connect to mains power and leave the battery on charge for a minimum of two hours before attempting to power on. Once the charge indicator shows at least 20%, the BMS recovery circuit re-initialises and the boot sequence completes normally.

Compatible Models

Moniteur Carescape Dinamap VC150 Carescape VC150 Vital Sign Monitor monitor Carescape Dinamap VC150

Replaces Part Numbers

2067981-027 5835030 M2844 4M00441A 110836-O 5923790

Technical Specifications

Voltage10.8V
Amp Hours5200mAh
Capacity5200mAh
Rate56.16Wh
Net Weight289.2g /10.20 oz
Gross Weight359.2g /12.67 oz
Approximate Weight359.2g /12.67 oz
Dimension 66.60 x 55.65 x 41.00mm

Product Highlights

  • Brand: GE
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The VC150 shows a low battery alarm the moment it finishes booting — the battery was on charge all night. What's causing this?

A new cell hasn't accumulated enough charge-cycle history for the VC150's BMS to trust the capacity reading. The monitor applies an OEM-calibrated threshold, and a fresh pack fails that check on the first boot regardless of charge state. Run the device on battery through one full discharge until the monitor initiates its own low-battery shutdown, then charge fully to 100%. After that first complete cycle the alarm clears on subsequent startups.

The VC150 switched off mid-monitoring and won't restart on battery, even though the charge indicator looked fine minutes before.

The VC150's load profile during active monitoring — particularly SpO2 and NIBP cycling together — draws harder than the steady-state current a new cell is conditioned for in the first ten cycles. A new pack can show a healthy state-of-charge at rest but sag below the BMS cutoff voltage under that combined load. This isn't a faulty battery — it's the cell stabilising. Complete two to three full charge-discharge cycles before placing the pack in clinical rotation, and the sag threshold rises to match the monitor's demand.

The charge indicator on the VC150 has been stuck below 100% for over an hour on a new battery — is the charger or the battery at fault?

The VC150's charge IC applies a conservative current limit on the first charge of a new cell, which extends the final topping phase significantly. The indicator stalls between 85–95% while the IC runs a slow trickle to verify cell acceptance — this is normal and not a charger fault. Leave the monitor on mains charge uninterrupted until the indicator reaches 100% and the charge LED changes state. Do not disconnect early; an incomplete first charge shortens the cycle count the BMS uses to estimate remaining capacity.

Payment & Security