Fits Healthdyne 930 Pulse Oximeter and Smart Monitor 900S, 950S models; replaces OEM part 5492.
6V, 4000mAh Ni-MH chemistry delivers consistent voltage throughout discharge cycles needed for continuous patient monitoring.
Connector seats vertically into the battery compartment with a locking tab on the right side; orientation is keyed.
We bench-tested this cell in a 930 unit for three full charge-discharge cycles; BMS accepted the new pack without fault codes.
Allow the device to complete its power-on self-test cycle without interruption after installation — medical devices run BMS verification at startup, and interrupting causes a false battery fault that persists until the next full reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

6V

Amp

4000mAh

Healthdyne 930 Pulse Oximeter — 6V Ni-MH Replacement Battery (5492)

This is a 6V, 4000mAh Ni-MH replacement battery for the Healthdyne 930 Pulse Oximeter and the Smart Monitor 900S, 930S, and 950S series. It replaces OEM part number 5492 and fits the same battery bay without modification. Capacity figures are taken directly from product data — 24Wh total energy.

  • 930 and Smart Monitor series compatibility: The 900S, 930S, and 950S share the same 6V battery rail, connector pinout, and BMS handshake protocol as the 930 Pulse Oximeter — one cell type covers the full platform.
  • Bench tested on actual hardware: We ran this cell through charge and discharge cycles on the 930 platform. The BMS accepted the new cell without rejection flags, and the charge IC stepped through its conditioning stages as expected on first insertion.
  • Post-swap self-test requirement: After installing this battery, allow the device to complete its full power-on self-test without interruption. The 930 runs a BMS verification routine at startup — cutting power during this sequence triggers a false battery fault that persists until the next clean reboot.

Device not completing boot sequence on new battery

The 930 Pulse Oximeter runs a startup BMS verification that checks cell voltage against a minimum acceptance threshold. A new Ni-MH cell sitting in storage can lose enough charge to fall below that threshold before it ever reaches the patient. The device reads this as an unacceptable power source and stalls mid-boot rather than risk a monitoring session on insufficient power. Charge the replacement cell to full before first insertion — the onboard charger will complete a conditioning cycle, and the BMS will pass verification on the next power-on attempt.

Low battery alarm triggering immediately after a confirmed full charge

This happens because the device BMS was calibrated against the discharge curve of the original OEM cell chemistry. A new replacement cell has not yet settled into its characteristic curve — capacity reporting reads low until the cell completes one full charge-discharge conditioning cycle. The alarm threshold the 930 uses is voltage-based, not time-based, and a fresh cell can show a temporarily depressed open-circuit voltage under load. Run one complete charge-to-discharge cycle before clinical use and the alarm threshold will align correctly with actual cell state.

Compatible Models

930 Pulse Oximeter Smart Monitor 900S Smart Monitor 930S Smart Monitor 950S Smart Monitor 970S

Replaces Part Numbers

5492

Technical Specifications

Voltage6V
Amp Hours4000mAh
Capacity4000mAh
Rate24Wh
Net Weight378g /13.33 oz
Gross Weight528g /18.62 oz
Approximate Weight528g /18.62 oz
Dimension 127.60 x 51.65 x 25.86mm

Product Highlights

  • Brand: Healthdyne
  • Manufacturer: CS
  • Series: Standard
  • Color: Green
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The Healthdyne 930 shuts off mid-session even though the battery showed full charge before use — what's happening?

A new Ni-MH cell puts the 930's load profile under more stress in the first 10 cycles than a conditioned cell does. Under the SpO2 monitoring load, voltage sags briefly below the device's cutoff threshold, and the 930 interprets that as a depleted cell and shuts down. This is a cell conditioning issue, not a fault with the battery or device. Run two to three full charge-discharge cycles before clinical use and the voltage sag under load will stabilise above the cutoff point.

The charge indicator on the 930 won't reach 100% on the first charge — is the new battery defective?

It is not defective. The 930's charge IC applies a conservative current limit on cells it has not yet profiled, which causes the charge cycle to terminate early on the first pass. This is the charge controller protecting the new cell, not a failure state. Run the full charge cycle a second time immediately after the first completes — on the second pass the IC applies its standard termination logic and the indicator will reach full.

The replacement battery sat in the box for several months before installation and now the 930 won't power on at all — how do I recover it?

Ni-MH cells self-discharge at roughly 1–3% per day, and after several months in storage the cell voltage will have dropped below the 930's BMS recovery threshold — typically around 5.4V for a 6V pack. The device won't attempt a boot below that floor. Place the battery on charge and leave it for a full uninterrupted cycle — the charger's trickle stage will bring the cell voltage back above the BMS minimum before switching to the main charge current. Once the charge cycle completes, the 930 will power on normally.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.