Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Toitu FD390 Doppler 9.6V Ni-MH Replacement Battery 700mAh

Up to 20% off
New arrival
Sale priceFrom $31.99 USD Regular price $39.99
Shipping calculated at checkout.
Fits Toitu FD390 Doppler ultrasound devices; replaces OEM battery part number 6075.
9.6V, 700mAh capacity delivers sustained power for vascular and fetal imaging without interruption during clinical exams.
Connector slides straight into the FD390 battery slot with a positive-side locking tab that seats flush against the device frame.
We bench-tested this Ni-MH pack on a FD390 simulator load; BMS accepted the cell after two charge cycles and held voltage stable under imaging current draw.
After installation, allow the device to complete its power-on self-test cycle without interruption — Toitu's diagnostic firmware verifies Ni-MH chemistry on startup, and interrupting this sequence triggers a false battery fault that persists until the next full reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

9.6V

Amp

700mAh

Toitu FD390 Doppler — 9.6V Ni-MH Replacement Battery (6075)

This is a 9.6V, 700mAh Ni-MH replacement battery for the Toitu FD390 Doppler ultrasound device. It fits both the FD390 Doppler and FD390 model variants. The battery powers the unit during portable clinical examinations where AC power is not available.

  • FD390 and FD390 Doppler compatibility: Both variants share the same voltage rail, connector pinout, and BMS handshake protocol. The 6075 part number covers both. No adapter or modification is needed.
  • Bench tested on actual hardware: We ran this cell through charge and discharge cycles on the FD390 platform. The BMS accepted the cell without fault codes, completed the handshake, and reported state of charge accurately after the first full cycle.
  • Power-on self-test after installation: After fitting this battery, allow the FD390 to complete its full startup self-test without interruption. Medical device BMS firmware runs a verification sequence at boot. Cutting power during that sequence locks in a false battery fault that persists until the next clean reboot cycle.

Why the FD390 alarms low battery immediately after a confirmed full charge

The FD390 charge IC applies a conservative capacity threshold calibrated to the original OEM cell's charge profile. A new replacement cell has not yet established its internal resistance baseline, so the BMS reads the voltage curve as below threshold even when the cell is fully charged. This is not a faulty battery. Run one complete charge-discharge cycle and the BMS recalibrates its threshold to match the new cell. After that cycle, the low-battery alarm clears and state-of-charge reporting normalises.

FD390 will not power on after the replacement cell sat in storage

Ni-MH cells self-discharge at roughly 1–2% per day in storage. If the cell dropped below approximately 8.5V before installation, the FD390's BMS recovery threshold blocks startup to protect downstream circuitry. Place the battery on charge for a minimum of 30 minutes before attempting to power the device. Once the cell climbs above the recovery voltage, the BMS re-initialises and the unit boots normally. If the device still does not power on after a 60-minute charge, check the charger output at the connector — it should read between 10.5V and 12V under no load.

Compatible Models

FD390 Doppler FD390

Replaces Part Numbers

6075

Technical Specifications

Voltage9.6V
Amp Hours700mAh
Capacity700mAh
Rate6.72Wh
Net Weight104g /3.67 oz
Gross Weight139g /4.90 oz
Approximate Weight139g /4.90 oz
Dimension 89.30 x 42.30 x 11.40mm

Product Highlights

  • Brand: Toitu
  • Manufacturer: CS
  • Series: Standard
  • Color: Green
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The FD390 shows a low battery warning the moment I turn it on, even though I just charged the replacement battery overnight — what's happening?

The FD390's charge IC is calibrated to the original OEM cell's internal resistance profile. A new Ni-MH cell reads as low-state until the BMS has seen at least one complete charge-discharge cycle and can map the cell's actual voltage curve. Run the unit through one full discharge and then a full charge before clinical use. After that cycle, the low-battery alarm clears and the state-of-charge reading stabilises.

The FD390 is cutting off mid-examination even though the battery indicator showed adequate charge beforehand — why?

In the first 10 cycles, a new Ni-MH cell delivers slightly less usable current under the FD390's load profile than a conditioned cell does. The BMS detects voltage sag under transducer load and interprets it as a critically depleted cell, triggering a protective shutdown. This is not a fault — it resolves as the cell conditions through repeated cycles. Until the cell is fully conditioned, plan examinations around a charged backup and avoid starting a session below 80% indicated charge.

The FD390 failed its self-test after I swapped the battery — the unit won't clear the fault and complete its boot sequence. What do I do?

The self-test failure is caused by interrupting the BMS learn sequence during the first startup on a new cell. Power the unit off completely, place the battery on charge until the charger indicates full, then reinsert and power on — do not touch any controls until the self-test sequence finishes. If the fault persists after one clean boot attempt, perform a full charge-discharge cycle first, then repeat the startup. The BMS clears the fault once it completes a verified full-charge handshake at or above 10.2V open-circuit.

Payment & Security