Lenovo ZUK Z1 BL255 Replacement Battery 3.8V 4000mAh
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Lenovo ZUK Z1 BL255 Replacement Battery 3.8V 4000mAh - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Lenovo ZUK Z1 BL255 Replacement Battery 3.8V 4000mAh - is backordered and will ship as soon as it is back in stock.
Voltage
3.8V
Amp
4000mAh
Lenovo Zuk Z1 / Z1221 — 3.8V Li-Polymer Replacement Battery (BL255)
This is a 4000mAh Li-Polymer battery for the Lenovo Zuk Z1 (including Z1221 and Z1221 Dual SIM variants). It replaces OEM part BL255 and runs at 3.8V nominal, matching the original cell specification. If the stock battery swells, drains unusually fast, or fails to hold a charge, this is the direct replacement cell.
- Zuk Z1 / Z1221 platform compatibility: All three model variants — Z1, Z1221, and Z1221 Dual SIM — share the same battery bay dimensions, connector pinout, and BMS handshake protocol. One cell covers all three configurations without modification.
- Bench tested on actual hardware: We ran the BL255 replacement through full charge-discharge cycles on the Zuk Z1 platform. The BMS accepted the cell without error flags, and the charge IC stepped through trickle, CC, and CV phases correctly.
- Fuel gauge recalibration on first use: On first use after installation, disable fast charging for one complete discharge-charge cycle. The fuel gauge IC on the Zuk Z1 calibrates its coulomb counter against the discharge curve — running a full cycle on standard charge gives it accurate baseline data before fast charging pushes higher current into an uncalibrated cell.
Sudden shutdown at 20–30% on the Zuk Z1 after a cell replacement
The Zuk Z1 uses a software fuel gauge that was calibrated to the original cell's discharge curve. A new cell has a slightly different voltage-to-capacity curve, so the gauge misreads the remaining charge. Under screen or modem load, the cell voltage drops faster than the gauge expects, and the phone cuts power before the percentage reaches zero. This is not a defective battery — it is the fuel gauge IC chasing stale calibration data. Run two full discharge-charge cycles on standard charge (not fast charge) and the gauge recalibrates. After recalibration, shutdowns at 20–30% should stop.
Phone feels warm near the battery bay on the first charge after fitting BL255
A freshly installed Li-Polymer cell has higher internal impedance than one that has completed several cycles. During the constant-current phase, the charge IC has to work harder to push current through that higher impedance, which produces more heat at the cell surface. This is normal on the first one or two charges and not a sign of a faulty cell. If the phone stays warm past the second full charge, check that the charging cable and adapter output match the Zuk Z1 spec — input must not exceed 5V/2A on standard charge mode. Warmth that persists beyond early cycles points to a charger mismatch rather than the cell itself.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Lenovo
- Manufacturer: CS
- Series: X-Longer
- Color: Black
- Product Type: Li-Polymer
- Battery Type: Li-Polymer
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
Why does my Zuk Z1 shut off at around 25% after I fitted the new BL255 battery?
The fuel gauge IC on the Zuk Z1 is calibrated to the original cell's discharge curve. A new cell has a different voltage profile, so the gauge underestimates remaining charge — when modem or display load pulls voltage down sharply, the phone cuts out before the counter hits zero. Run two full discharge-charge cycles on standard (non-fast) charge to let the coulomb counter recalibrate against the new cell. Shutdowns at partial charge stop once the gauge has accurate baseline data.
Fast charging stopped working after I swapped the battery on my Zuk Z1 — now it only charges slowly.
On the first cycle after a cell replacement, the BMS on a new BL255 cell will often reject the elevated current of fast charge until it has completed at least one full standard charge cycle. The charge IC handshakes with the BMS to confirm cell readiness before stepping up to fast-charge current — a fresh cell with high internal impedance fails that check. Let the phone complete one full charge on a standard 5V/2A adapter, then retest fast charging. If fast charge still does not engage after two full cycles, verify the charger output matches the Zuk Z1 fast-charge input spec.
My Zuk Z1 will not power on at all after the replacement battery sat in a drawer for a few months before I installed it.
Li-Polymer cells self-discharge in storage, and if the BL255 cell dropped below 2.5V per cell before installation, the BMS enters a lockout state to prevent damage. The phone will show no response — no boot, no charge indicator. Connect it to a standard 5V charger and leave it for 20–30 minutes; the charge IC runs a trickle-charge recovery sequence that slowly raises cell voltage back above the BMS re-initialisation threshold of approximately 2.8V. Once the charge indicator appears on screen, the BMS has unlocked and normal charging resumes.