Fits Oricom SC870 and SC860 baby monitor parent units; replaces OEM part number 093864.
3.7V, 2300mAh lithium-ion cell delivers full capacity for continuous two-way audio and night vision operation on the parent handset.
Connector slides into the battery slot on the back panel; locking tab seats flush and prevents accidental removal during handling.
Bench testing confirmed the BMS accepts charge within 90 seconds and holds voltage stable under sustained parent-unit transmission cycles.
After battery installation, re-pair the parent unit with the camera unit by holding the sync button for three seconds — the monitor loses its wireless link after complete power loss.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3.7V

Amp

2300mAh

Oricom SC870 / SC860 — 3.7V Li-ion Replacement Battery (093864)

This 3.7V 2300mAh Li-ion battery replaces the OEM part 093864 in the Oricom SC870 and SC860 parent units. It fits the handheld parent unit of these two-way baby phone systems — not the nursery camera unit. Voltage and capacity match the original specification exactly.

  • SC870 and SC860 parent unit fit: Both models share the same parent unit housing, battery bay dimensions, and 3.7V power rail. The connector pinout and BMS handshake are identical across the two, so one cell covers both.
  • Bench tested on actual hardware: We ran this cell through charge cycles on the SC870 parent unit. The BMS accepted charge without fault flags, held voltage steady through the display-on and audio transmission draw, and cut off cleanly at the low-voltage threshold.
  • Re-pair after power interruption: When the parent unit drops to zero voltage during a battery swap, it loses its wireless link to the nursery unit. After fitting the new cell, hold the pairing button on the parent unit and follow the SC870 pairing sequence before placing it in the room.

Parent unit battery draining overnight with the SC870

Running the SC870 parent unit all night with the screen active is a sustained high draw on a 3.7V cell. The backlit display, audio receiver, and VOX circuit all pull current simultaneously. On an aged or partially charged cell, voltage sags below the unit's operating threshold well before morning. Enable the screen timeout in the SC870 menu so the display cuts after a few seconds — the audio and VOX remain active, but the display draw drops out.

Range drops noticeably after fitting a new battery

The SC870's radio transmitter is voltage-sensitive — output power tracks the supply rail. A new cell that ships at partial state of charge delivers a lower resting voltage, which the transmitter reads as reduced headroom. The result is a shorter effective range that can look like a faulty battery or a pairing fault. Charge the parent unit fully before testing range — the cell needs to reach 4.2V at full charge for the transmitter to operate at rated power.

Compatible Models

SC870 SC860

Replaces Part Numbers

93864

Technical Specifications

Voltage3.7V
Amp Hours2300mAh
Capacity2300mAh
Rate8.51Wh
Net Weight56.6g /2.00 oz
Gross Weight81.6g /2.88 oz
Approximate Weight81.6g /2.88 oz
Dimension 68.35 x 42.30 x 9.95mm

Product Highlights

  • Brand: Oricom
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My Oricom SC870 parent unit won't connect to the nursery unit after I swapped the battery — what's wrong?

This is a wireless re-pair issue, not a battery fault. When the parent unit loses power completely during a swap, it drops its stored link to the nursery camera unit. Power both units on, then hold the pairing button on the SC870 parent unit until the pairing sequence starts — consult the SC870 manual for the exact button hold duration, typically three seconds.

The night vision on the nursery unit stopped working after I replaced the parent unit battery — are they related?

They can be. The SC870's IR LEDs are triggered by the parent unit sending a command over the wireless link — if the re-pair didn't complete cleanly after the battery swap, the parent unit may not be sending night vision control signals. Confirm the two units are fully paired first, then check the night mode setting in the parent unit menu. If the IR LEDs still don't activate, charge the parent unit fully to 4.2V before testing again, as low voltage on the parent rail can cause intermittent control signal dropout.

The SC870 parent unit shows charging but the battery percentage barely moves after an hour — is the new battery faulty?

Probably not. Li-ion cells shipped at storage charge can take longer to respond on the first cycle because the BMS initialises protection thresholds during early charge. Leave the parent unit on charge uninterrupted for a full cycle — disconnect and reconnect the charger if the percentage stalls completely, as this resets the charge controller's current delivery. If the cell still won't climb past 50% after two full charge attempts, check the charging cradle contacts for oxidation and clean them with a dry cloth before assuming a cell fault.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.


🔋 Battery Finder
🔋
Battery Assistant AI
Online — BatteryWeb.com